Remote Reading Ultrasonic Water Meter
Negotiable /Set
Min.Order:1 Set
Huizhong Instrumentation Co., Ltd.
Remote Reading Ultrasonic Water Meter
SCL-61D2 series DN50~DN300, mm
Features:
♦ The meter is multi-channel design. Highest possible in measuring accuracy under various pipe flow conditions.
♦ Without mechanical moving parts.
♦ Highly sensitive to a minimal starting flow rate. A flow rate as low as 0.002m/s can be precisely measured.
♦ Measuring cycle is once per second and the power consumption ≤0.5mW.
♦ Battery-powered. Battery life is over 10 years.
♦ High in reliability and anti-magnetic interference.
♦ The meter provides Photoelectric, RS-485 output interfaces
♦ CE, ISO 9001, ISO 14001 and ISO 18001 certificates.
♦ The Protection class is IP68.
The effect of IP68:
Applications:
The meter is designed for urban water supply and various industrial sites where power sources are unavailable.
Tangshan Huizhong Instrumentation Co., Ltd - Manufacturer of Ultrasonic water meter, Flow meter and Heat meter.
If any inquiries or question, don't hesitate to contact me.
Item | Parameter |
SCL-61D2 | |
Accuracy Class | 2 |
Nominal Diameter,mm | DN50~DN300 |
Medium | Full pipe flow of water, Sewage or other homogeneous fluids |
Range of Pressure loss | Δp10 |
Max. Permissible working Pressure | 1.6Mpa (DN200: standard value 1.0Mpa) |
Working Environment | Temperature: -25℃~+55℃; RH ≤100% (If the limit is exceeded, please specify when ordering) |
Temperature range | T30, T50, T70, default:T30 |
Sensitivity Class of Upstream Flow Field | U5 |
Sensitivity Class of Downstream Flow Field | D3 |
Climate & Mechanical Environment Conditions | C |
Class of Electromagnetic Compatibility | E2 |
Keyboard | Magnetic induction keys |
Display | LCD 8 digital+prompting characters, Word height: 8.5mm |
Content of display | Instantaneous flow ate: m³/h; Cumulative flow rate: m³; Total effective running time: h; Date: y/m/d; Clock: h/m/s |
Range of display | Cumulative flow rate: -9999999.9m³~+99999.999m³ Instantaneous flow ate: -999999.99m³/h~+999999.99m³/h |
Type of Communication | Photoelectric interface --Baud rate: 2400bps, Protocol: EN13757 |
RS-485 --Baud rate: 2400bps (default), 4800bps, 9600bps (Selectable) Transmission distance: ≤1200m Protocol: Huizhong, Modbus, EN13757(selectable), Default: Huizhong | |
Data storage(EEPROM) | Storage of cumulative flow rate and effective running time. (Data can be saved for a period of 100 years after power failure). The above mentioned data can be automatic stored within 24 months. |
Working Power | Battery DC 3.6V ( The service life of battery >10 years) |
Measuring Cycle | Once per second |
Protection Class | IP68 |
Power consumption | <0.5mW |
Range of Flow rate Parameters, SCL-61D2( Accuracy class: 2)
Nominal Diameter, (mm) | Min. Value Sensible (m³/h) | Q3/Q1 | Q2/Q1 | Min. Flowrate Q1 (m³/h) | Boundary Flowrate Q2 (m³/h) | Permanent Flowrate Q3 (m³/h) | Overload Flowrate Q4 (m³/h) | Cumulative Flowrate | |
Max.Reading (m³) | Min.Reading (m³) | ||||||||
50 | 0.013 | 125 | 1.6 | 0.504 | 0.806 | 63 | 78.75 |
9999999.9 |
0.001 |
65 | 0.022 | 125 | 1.6 | 0.800 | 1.280 | 100 | 125.00 | ||
80 | 0.034 | 125 | 1.6 | 1.280 | 2.048 | 160 | 200.00 | ||
100 | 0.054 | 250 | 1.6 | 1.000 | 1.600 | 250 | 312.50 | ||
125 | 0.088 | 250 | 1.6 | 1.600 | 2.560 | 400 | 500.00 | ||
150 | 0.121 | 250 | 1.6 | 2.520 | 4.032 | 630 | 787.50 | ||
200 | 0.215 | 250 | 1.6 | 4.000 | 6.400 | 1000 | 1250.00 | ||
250 | 0.336 | 250 | 1.6 | 6.400 | 10.240 | 1600 | 2000.00 | ||
300 | 0.483 | 250 | 1.6 | 6.400 | 10.240 | 1600 | 2000.00 |
1 piece in one wood box.