In-line Ultrasonic Flow Meter with IP68 and Good Price
Negotiable /Set
Min.Order:1 Set
Huizhong Instrumentation Co., Ltd.
In-line Ultrasonic Flow Meter with IP68 and Good Price
SCL-61 series DN15mm~DN600mm
Application
SCL-61 In-line ultrasonic flow meter is suitable for industrial environments, especially under the condition with electromagnetic interference.
Special Features
1.SCL-61 In-line ultrasonic flowmeter operates with advanced multi-pulse, DSP digital signal processing and error correction technologies.
2.The ultrasonic flow meter is battery powered with a micropower consumption design and a measuring cycle of one second .
It can work uninterruptedly for a period of over 10 years with only one battery(power consumption: <0.5mW)
3.The ultrasonic flow meter is of a through-bore design and has no mechanical moving parts.
4. The ultrasonic flow meter is highly sensitive to a minimal starting flowrate with a high accuracy.(A flow velocity as low as 0.002m/s can be
detected).
5.Two design versions are available,i.e. the ordinary and 2-way versions to cater to the different needs of users.
6.The meters are in conformity with "Standard on Ultrasonic Flowmeter for Water Supply and Drainage Application"(CJ/T3063/1997)-a standard formulated by the Ministry of Construction of the People’s Republic of China.
7.EX-factory calibration of the meter is made in accordance with P.R.C callibration regulations as specified in "Ultrasonic Flowmeter "JJG 1030-2007.
8. The meter passed the CE, ISO 9001, ISO 14001 and ISO 18001 certificates.
Technical Specifications
Capability | SCL-61 In-line Ultrasonic Flowmeter | ||
Type of Transducer | Single-path Version | Multi-path Version | Embedded Version |
Measured Fluids | Full pipe flow of water, sewage and other homogenous fluids | ||
Accuracy (%) | ±1.0 | ||
Pipe Size Range Adaptable (mm) | DN15~DN300 | DN50~DN300 | DN350~DN600 |
Pressure-bearing Capacity of Pipe Section | 1.0MPa / 1.6MPa | ||
Working Environment | Temperature: -10°C~+45°C; Humidity≤85% (RH) (For use under otherwise specific conditions, please specify on ordering.) | ||
Medium Environment | Normal-temperature version: -10℃~50℃; High-temperature version: 0℃~130℃ | 0℃~50℃ | |
Output Signal | 4~20mA(a DC 24V power supply is needed), RS- 485. | ||
Input | Photoelectric interface / Magnetic induction key | ||
Display Mode | 8-digit LCD+prompting character , Word height:8.5mm, Self-diagnosis presentation: the meter working status display"ERR", Battery symbol | ||
Display | Instantaneous flowrate: m³/h; Comulative flowrate: m³; Cumulative effective running | ||
Data Storage | Comulative flowrate and cumulative effective running time (Data can be saved in EEPROM | ||
Power Supply | Powered by one battery, capable of operating continuously for a period of over 10 years | ||
Measurement Cycle | check and calibration status: 4 times/second; Normal status: 1 time/second | ||
Protection Class | Integral version: IP68; Conversion unit of non-integral version: IP68; Display of non-integral version: IP68 | ||
Power Consumption | <0.5mW | ||
Display-conversion unit connecting cable for non-integral model: standard length 6m. For non-standard cable length, please specify |
Range of Flow rate Parameters, SCL-61 Inline ultrasonic flow meter( Accuracy class: 1)
Nominal Diameter, (mm) | Measuring Mode | Min. Value
Sensible (m³/h) | Min. Flowrate Qmin (m³/h) | Boundary Flowrate Q1 (m³/h) | Max.Flowrate Qmax (m³/h) | Cumulative Flowrate | |
Max.Reading (m³) | Min.Reading (m³) | ||||||
15 | S-C | 0.002 | 0.020 | 0.190 | 1.8 |
9999999.9 |
0.001 |
S-C | 0.002 | 0.015 | 0.190 | 3 | |||
20 | S-C | 0.002 | 0.030 | 0.330 | 3 | ||
S-C | 0.002 | 0.025 | 0.330 | 5 | |||
25 | S-C | 0.005 | 0.070 | 0.520 | 7 | ||
S-C | 0.005 | 0.035 | 0.520 | 7 | |||
32 | S-C | 0.007 | 0.120 | 0.860 | 12 | ||
40 | S-C | 0.011 | 0.200 | 1.350 | 20 | ||
50
| S-C | 0.035 | 0.800 | 2.110 | 90 | ||
M-C | 0.013 | 0.630 | 2.110 | 90 | |||
65 | S-C | 0.060 | 1.000 | 3.580 | 120 | ||
80
| S-C | 0.090 | 1.250 | 5.420 | 170 | ||
M-C | 0.034 | 1.000 | 5.420 | 170 | |||
100
| S-C | 0.141 | 1.280 | 8.470 | 240 | ||
M-C | 0.054 | 1.000 | 8.470 | 240 | |||
125 | M-C | 0.221 | 1.563 | 13.240 | 330 | ||
150
| S-C | 0.318 | 3.125 | 19.070 | 400 | ||
M-C | 0.121 | 2.500 | 19.070 | 400 | |||
200
| S-C | 0.565 | 5.000 | 33.910 | 560 | ||
M-C | 0.215 | 4.000 | 33.910 | 560 | |||
250
| S-C | 0.883 | 8.000 | 52.980 | 700 | ||
M-C | 0.336 | 6.349 | 52.980 | 700 | |||
300
| S-C | 1.270 | 12.60 | 76.300 | 800 | ||
M-C | 0.483 | 7.875 | 76.300 | 800 | |||
350 | E | 1.700 | 20.00 | 103.850 | 840 | ||
400 | E | 2.260 | 25.00 | 135.640 | 1300 | ||
450 | E | 2.860 | 32.00 | 171.670 | 1600 | ||
500 | E | 3.530 | 40.00 | 211.950 | 1900 | ||
600 | E | 5.090 | 62.50 | 305.200 | 2700 |
Note:1.S-C:Single-channel
M-C:Multi-channel
E:Embeded version
2.Huizhong series ultrasonic flowmeter is capable of working stably at max.flowrate point.Display data will start again from 0 when cumulative flowrate exceeds max.reading.
1 set in one carton.
FOB or CIF. Can be shipped by sea, air or train
Our company provides OEM service, design and buyer's label service
Quality Assurance
Sophisticated equipment and scientific manufacturing process are the gurantee of our superior quality products.
All the manufacturing processes of our products starting from supply of raw materials,preliminary test down to inspection on of finished products are carried out strictly in compliance with the standard of international quality system ISO 9001: 2008.
Tangshan Huizhong Instrumentation Co., LTD is currently China’s R&D and manufacture base of series ultrasonic heat meters,
water meters and flowmeters and related systems. It is also a new and hi-tech and software enterprise of Hebei province.
Whenever you have questions or inquiries, don't hesitate to contact with me at any time.