2-channel Clamp-on Ultrasonic Water Flow Meter (SCL-82)
DN80~DN1800,mm
Features:
♦ SCL- 82 ultrasonic flowmeter is used for measuring full flow in closed pipes with the “velocity difference” methods as its operating principle.
♦ Working on double measuring channels, highly adaptable to various complex flow conditions.
♦ Accuracy as high as 1.0 class.
♦ Tranducer's type is clamp-on. Mounting and maintenance of the meter can be made on line with water flow.
♦ It consists of 2 parts: Conversion unit and transducer.
Application:
The meter is adaptable to different flow regimes, and can find widespread applications in oil, chemical, metallurgical, power, and water supply and drainage sectors.
Technical data:
Performance | SCL-82 | ||||
Type of transducer | Clamp-on type | ||||
Fluid measured | Water, sewage and other homogeneous fluids in full pipe flow, and the suspended solid content shall be no more than 10g/L | ||||
Material of pipeline | Material like steel, cast iron, PE, and PVC etc, which pipe section can be penetrated by ultrasonic wave | ||||
Material of transducer | 304 (Stainless steel) | ||||
Pipe size adaptable (mm) | DN80~DN1800 | ||||
Accuracy | 1.0/1.5 | ||||
Flow velocity adaptable (m/s) | 0.25m/s-12.00m/s (qt=0.3m/s) | ||||
Max. pressure-bearing capacity of transducer | Has nothing to do with the pressure in pipe | ||||
Immersion depth of transducer: ≤ 3m | |||||
Temperature of fluid measured | 0℃~50℃ (Normal version), 0℃~90℃ (High temperature version) | ||||
Ambient of conversion unit | Temperature: -10℃~+45℃; Relative humidity: ≤ 85%RH (Please specify on ordering) | ||||
Ambient of transducer | -40℃~+45℃ (Normal version), -40℃~+70℃ (High temperature version) | ||||
Output of conversion unit | Digital | RS-485; Baud rate: 2400bps, 4800bps, 9600bps (Selectable), Default: 4800bps. Transmission distance≤ 1200m. Available with Huizhong, Modbus and RTU communication protocols. | |||
Analog | Optical-isolated 4~20mA, 0~10mA, or 0~20mA. Load capacity: ≤ 600Ω | ||||
Switch | Active output (Specify on ordering) | Output voltage: DC24V (Max.); Output current: 20mA (Max.) | |||
Passive output | Load voltage: DC30V (Max.); Load current: 20mA (Max.) | ||||
Transmission distance ≤ 500m | |||||
Keys | 1×3 induction button | ||||
Display | Non-integral type | 240×64 graphics dot-matrix LCD | |||
Panel-mounted type | 2×16-digit character dot-matrix LCD | ||||
Data display | On screen display | Cumulative flowrate(m³), Instantaneous flowrate(m³/h), Signal strength indication, Working status indication, Fault display | |||
Key display | Positive cumulative flowrate(m³), Negative flowrate(m³), Instantaneous flowrate(m³/h), Flow velocity (m/s), Running time(h), Version No., Date(Y/M/D), Time(H/M/S) | ||||
Display range | Cumulative flowrate: -9999999.9~+9999999.9m³; Instantaneous flowrate: -999999.99~+999999.99m³/h | ||||
Data storage | Storage of cumulative flowrate, running time and different setting parameters,automatically stored of latest 150 days’ daily and latest 60 months’ monthly previous data; data will be stored for 100 years even in case of a power failure. Daily previous data and monthly previous data include below: date, positive cumulative flowrate, negative cumulative flowrate, algebraic sum of cumulative flowrate and corresponding running time. | ||||
Power supply | AC220V±10%, 50Hz (Or AC110V±10%, 60Hz), Power < 5W. DC12V-DC36V, 1A (Please specify on ordering) | ||||
Protection class | Conversion unit | IP65 | |||
Transducer | IP68 | ||||
Weight of one pair of transducers | 1 kg (10m cable included) | ||||
Length of cable (Wiring distance) | (10×n)m, n: 1-20 |
Our company provides OEM service, design and manufacture, buyer's label service.
Tangshan Huizhong Instrumentation Co., Ltd - Manufacturer of Ultrasonic water meter, Flow meter and Heat meter.