MD Low Frequency UPS
USD $500 - $8,000 /Set
Min.Order:1 Set
Shenzhen Santek Power Co., Limited
Low Frequency Ups Single Phase(1/1)
Brief introduction
MD series online UPS, an fully intelligent digital UPS, highly combines the latest controller and the most advanced software. It takes the sixth generation low-exhaust and big-power IGBT and static switch as power devices. This kind of UPS is a perfect production of us. It adopts the digital controlling technology, of which the core is high-speed on-line programmed microprocessor.
Main Features
1.Pure sine wave output, true on-line dual conversion design
2.SMD technology.
3.High efficiency IGBT (Insulated Gate Bipolar Transistor) inverter technology
4.LCD display, with the simple operation and Intuitive data, optional display language and logo
5.Intelligent detecting function
6.Excellent load feature
7.Cold start
8.Generator compatible
9.Intelligent communication
10.Perfect protection.
Input/output over/low voltage protection, input surge protection, phase sequence protection, battery over charge/discharge protection, short circuit protection, over-temperature protection and so on, as well as alarm function.
11.Selectable battery inspection module
Specification
Model | MD-1K | MD-2K | MD-3K | MD-4K | MD-6K | MD-8K | MD-10K | MD-15K | MD- 20K | ||||
Nominal capacity(KVA) | 1KVA | 2KVA | 3KVA | 4KVA | 6KVA | 8KVA | 10KVA | 15KVA | 20KVA | ||||
Working principle | Pure sine wave on line | ||||||||||||
Phase | 1phase+N+G | ||||||||||||
Input Power factor | >0.85 | ||||||||||||
Rectifier | Input voltage | 220VAC; 230VAC; 240VAC | |||||||||||
Range | ±25% | ||||||||||||
Nominal input frequency | 50Hz±10%;60Hz±10%; | ||||||||||||
Charge | Charge mode | constant current to constant voltage, with temp compensation; with Auto change | |||||||||||
Battery | Battery type | maintenance-free lead acid battery | |||||||||||
Battery number | 4pcs 12V | 16pcs 12V | |||||||||||
Rated power | Rated capacity ×0.8 | ||||||||||||
Nominal Voltage | 220VAC; 230VAC; 240VAC | ||||||||||||
Output frequency stability | 50Hz 60Hz<±0.5% | ||||||||||||
Crest factor | >3:1 | ||||||||||||
Overload protection | 150% 1min; 200% 1S | ||||||||||||
Efficiency | >93%(full load) | ||||||||||||
Bypass | Phase | Single phase+N | |||||||||||
Nominal voltage | 220VAC; 230VAC; 240VAC | ||||||||||||
Transfer time | <1mS( static switch with 0 S ) | ||||||||||||
Protection | Input protection | Input voltage /frequency over limited protection | |||||||||||
Output protection | Over current; short circuit ; factor low protection | ||||||||||||
Battery protection | Over charge ; over-discharge protection | ||||||||||||
Temperature protection | Environment over temperature protection; inverter over temperature protection | ||||||||||||
Hardware failure protection | Assistant power abnormal, breaker cut off ,breaker overload, power devices over current/over voltage etc protection | ||||||||||||
System Parameters | Working environment | Temp: 0~40ºC, relative humidity 30%~90% ( 1% decrease against 100 meters’ rise. Altitude 4000m MAX) | |||||||||||
Redundancy function | Tandem hot backup or parallel connection | ||||||||||||
Noise (dB) | 45~60 | ||||||||||||
Dimension(W×D×H)mm | 210*452*510 | 220*578*540 | 380*900*680 | 430*750*1050 | |||||||||