220KV Oil Immerse Power Transformer

220KV Oil Immerse Power Transformer

Negotiable /Set

Min.Order:1 Set

Supply Ability:
50 Set / Sets per Month
Port:
Shanghai
Payment Terms:
T/T

Quick Details View All >

Place of Origin:
Zhejiang, China
Brand Name:
GEM
Model Number:
SF11
Usage:
Power
Phase:
Three
Coil Structure:
Toroidal

Liaoning Mec Group Co., Ltd.

Business Type: Trading Company
Dalian Liaoning China
Main Products: Mechanical product ,electrical product ,light industrial product

Product Details

Specifications

Oil Immerse Power Transformer ,with phase or 3 phases, oil-immersed,
with capacity from 25KVA to 200MVA,110KV-500KV

Oil Immerse Power Transformer Detail Information

220KV Power Transformer detailed information

1) CTQC,ISO9001,ISO14001,CE.  2) Apply for IEC,GB,ANSI3) Up to 230kV,240MVA

 

Technologies

 

Core

 

1) The core is made of high-permeable grain-orientated top quality cold-rolled silicon sheet and the material is cut with advanced Germany Geoge GmbH automatic shear line with the cut burs controlled within 0.02mm.

 

2)The silicon sheet fabrication adopts “no-upper yoke lapped’ technology and all lapped joints of the silicon sheet are 45 full-miters. The laminated  core sheets are integrally pressed and adhered with epoxy resin to make the three –leg two-yoke core a strong and flat integral one with good verticality precision, this effectively improves no-load performance and reduces noises.

 

 Winding

 

1) The high-voltage (HV) coil adopts an interleaved-continuous structure to improve the voltage characteristics under impact voltage and make voltage evenly distributed. All stays and pads are chamfered to keep highly reliable insulation.

 

2) In the transformer winding there is a zigzag oil guide structure so as to fully cool all areas inside the winding, lower the temperature rise of the winding and the hot points of the winding and prolong the service life of insulation. The HV and MV regulation system are independently provided with voltage-regulating winding to balance the ampere turn of each winding,  effectively lower the axial electrodynamic force generated at short-circuit of transformer and improve abrupt short-circuit withstanding capacity.

 

3) The winding adopts radial “0” margin designed, between the core and the paper sleeve of LV winding, and between the LV, HV, voltage-regulating windings, as well as before insertion of stays and shroud plate they are fully dried and tightly matched to ensure extremely good compactness and concentricity of the entire winding.

 

Oil tank and accessories

 

1)  The tank wall adopts wide steel sheet, which will be folded into corrugated structure without splicing, in this way welds are decreased and mechanical strength is enhanced, meanwhile, the corrugated wall has diverging effect, and thus plays a role in decrease of noise. The routing troughs and control cabinets of the secondary circuit are all made of stainless steel, so the entire transformer has a simple and good looking. All sealing surface use quality sealing material and are precision-machined.

 

2)  On the edge of the tank there are double sealing grooves, and the outer sealing material is used to shade the atmosphere and ultra-ray to protect the inner sealing being damaged, thus at utmost prolonging service life and enhancing reliability of the seal.

Main technical parameters for three-phase two winding on-load-tap-changing power transformer

Rated power
(kVA)


High Voltage
(kV)


H.V Tap range


Low Voltage
(kV)


Connection Symbol


Short-Circuit Impedance
(%)


No-load Loss
(kW)


On-Load Loss
(kW)


No-load Current
(%)

9 Type

10 Type

11 Type

9 Type

10 Type

11 Type

31500

220
242

±8×1.25%
±8×1.5%

6.3,6.6,
10.5,11,
20,34.5,
35,37,
38.5,66,
69

YNd11

12~14

38

34

30

135

128

128

0.7

40000

45

41

36

157

149

149

0.63

50000

54

49

43

189

180

180

0.56

63000

63

57

50

220

209

209

0.56

90000

80

72

64

288

274

274

0.49

120000

99

89

79

346

329

329

0.49

150000

116

104

93

405

385

385

0.42

180000

135

122

108

468

445

445

0.42

Main technical parameters for three-phase two winding non-excitation-tap-changing power transformer

Rated power
(kVA)


High Voltage
(kV)


H.V Tap range


Low Voltage
(kV)


Connection Symbol


Short-Circuit Impedance
(%)


No-load Loss
(kW)


On-Load Loss
(kW)


No-load Current
(%)

9 Type

10 Type

11 Type

9 Type

10 Type

11 Type

31500

220
242

±8×1.25%
±8×1.5%

6.3,6.6,
10.5,11,

13.8,15.75
20,35,
38.5,

YNd11

12~14

35

135

32

128

28

128

0.7

40000

41

157

37

149

33

149

0.7

50000

49

189

44

180

39

180

0.65

63000

58

220

52

209

46

209

0.65

75000

67

250

60

238

54

238

0.6

90000

77

288

69

274

62

274

0.55

120000

94

345

85

328

75

328

0.55

150000

112

405

101

385

90

385

0.5

160000

 

 

 

117

425

105

404

94

404

0.49

180000

 

 

 

128

459

115

436

102

436

0.46

240000

 

 

 

160

567

144

539

128

539

0.42

Instection 

220KV Oil Immerse Power Transformer220KV Oil Immerse Power Transformer

Packing and Loading

220KV Oil Immerse Power Transformer220KV Oil Immerse Power Transformer220KV Oil Immerse Power Transformer220KV Oil Immerse Power Transformer


 

Contact Supplier

Mr. Xu Yi Member Chat Now
Telephone
86-411-39803333
Fax
86-411-39803301
Address
28/F, World Trade Center, 25 Tongxing Street, Dalian, Liaoning Province. China Dalian,Liaoning

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Transformers
Categories
Hi~