Acrel Current input isolation safety barrier BM200-DI/I-C22 isolation transmission outputs 2 independent DC0/4-20mA signals
Acrel Current input isolation safety barrier BM200-DI/I-C22 isolation transmission outputs 2 independent DC0/4-20mA signals
Acrel Current input isolation safety barrier BM200-DI/I-C22 isolation transmission outputs 2 independent DC0/4-20mA signals
Acrel Current input isolation safety barrier BM200-DI/I-C22 isolation transmission outputs 2 independent DC0/4-20mA signals
Acrel Current input isolation safety barrier BM200-DI/I-C22 isolation transmission outputs 2 independent DC0/4-20mA signals

Acrel Current input isolation safety barrier BM200-DI/I-C22 isolation transmission outputs 2 independent DC0/4-20mA signals

Negotiable /Piece

Min.Order:1 Piece

Supply Ability:
100 Piece / Pieces per Month
Payment Terms:
T/T L/C

Acrel Electric Co., Ltd

Business license
Business Type: Manufacturer
Shanghai China
Main Products: Hall Sensor ,Split Core Current Transformer ,AC Energy Meter ,DC Energy Meter ,IoT Wireless Power Meter ,PV/Solar Inverter Energy Meter ,Data Center Power Meter ,Wireless Temperature Monitoring System and Sensors ,Medical IT Products ,City Utility Tunnel Moter Protector ,Electrical Insulation Safety Products ,Energy Quality Improvement

Product Details

BM200 isolated safety barrier can transmit signals between the safe area and the dangerous area, and limit the energy transfer from the safe area to the dangerous area caused by the fault. The voltage, current, temperature, resistance signals generated by the equipment (transmitter) on the dangerous side are isolated and converted into corresponding linear voltage and current signals outputting to the safe area. The product requires independent power supply, and the input/output/power supply is isolated. It can be used in current source, two-wire, three-wire transmitter equipment. 

① DC voltage/current input

② Using magnetic isolation technology

③ Response time<400ms

④ TS35 rail installation

⑤ Plug-in terminal

⑥ Temperature drift coefficient: ≤200ppm/℃ at 0.5 level

Technical Parameter
Channel type
Single-way input and single-way output,
single-way input and double-way output,
double-way input and double-way output
Input type
Current/Voltage/Thermal resistance Pt100/Resistance/Thermocouple
Input signal
0~20mA /4~20mA
0~5V /0~10V /1~5V (Distribution voltage: 12V/20mA)
PT100 /0~10K/K、E、T、J、N、R、S、B
Output signal
0~20mA /4~20mA (Safe side input); Load resistance: ≤550Ω
0~5V /1~5V (Safe side input); Load resistance: ≥330K
0~10V (Safe side input); Load resistance: ≥500K
Transmission accuracy
0.20%
Temperature modulus
50ppm/℃ (The output signal is current)
Response time
5ms to reach 90% of final value
(RTD Pt100/resistance/thermocouple input: 1s to reach 90% of final value)
Power supply
20~35V DC
Work temperature
-20℃~+60℃
Fix mode
Rail installation
Dielectric strength
Intrinsically Safe and Non-Intrinsically Safe ≥2500V AC; Power supply and
Non-Intrinsically Safe ≥500V AC
Note:Intrinsically Safe is input, Non-Intrinsically is output
Dimension
Wiring
Solution Structure
Application
Payment & Delivery
Company Profile


Contact Supplier

Ms. Shelly Zhang sales manager Chat Now
Telephone
86-21-18702111813
Mobile
86-18702111813
Fax
86-21-69155906
Address
No.253 Yulv Road, Jiading District, Shanghai
Whatsapp
86-18702111813

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electronic Components & Supplies > Other Electronic Components
Categories
Hi~