Overhead Line fault indicator for Generator, Transformer, Cables, Loads
Overhead Line fault indicator for Generator, Transformer, Cables, Loads
Overhead Line fault indicator for Generator, Transformer, Cables, Loads
Overhead Line fault indicator for Generator, Transformer, Cables, Loads
Overhead Line fault indicator for Generator, Transformer, Cables, Loads

Overhead Line fault indicator for Generator, Transformer, Cables, Loads

Negotiable /Piece

Min.Order:1 Piece

Supply Ability:
10000 Piece / Pieces per Month
Payment Terms:
T/T

Quick Details View All >

Brand Name:
SNOVA
Place of Origin:
China
Model Number:
SNV308.1

Zhuhai City Snova Technology Co., LTD

Business license
Business Type: Manufacturer
Zhuhai Guangdong China
Main Products: Earth Fault Indicator ,Cable Fault Indicator ,Overhead Line Ground Fault Indicator ,Short Circuit and Earth Fault Indicator ,Cable Temperature and Faults Sensor ,Industrial Dehumidifier ,Temperature and Humidity Controller ,Fault Passage Indicator ,Remote communication terminal ,Smart grid system

Product Details

What is the overhead line fault passage indicator (FPI)?

SNOVA Overhead line fault indicator is a device which provides visual or remote indication of fault in electrical distribution network. When a fault occursIt can automatically detect whether the fault type is short circuit or ground fault. Then indicated by red mechanical flag and three ultra-bright blinking LEDs, which can be seen from 360º sight. The fault information and load current value can also be transmitted to the SCADA by 2G/3G/4G networks.

Why are FPI important in distribution networks

In the outdoor environment, electrical networks are subject to the damage of nature throughout the year. From lighting, heavy rain, dust or even just local wildlife, these electrical networks become easy to occur faults.

When these faults occurpower outages can affect end-users and industrial areas, causing huge  losses in this  time, the SNOVA fault indicator plays an important role, it can help the utility attain early information on fault location and fault type, and t. Therefore, the administrator can quickly find out the cause of the fault and restore the power supply to reduce losses.

 

How does the FPI work?

SNOVA fault indicator ,One fault passage indicator is usually clipped onto each phase. By placing the FPI ‘s at regular intervals along the line, it can identify faults in the downstream section from its point of installation by monitoring the electromagnetic field surrounding the conductor. When fault occurs, Indicator will detect the current character, though a complicated calculation, then judge if a fault occurs, and what the fault type is. At same time, FPI sense this condition, immediately gives the alarm on-site and remotely to SCADA system.

 

In the case of non-communicable type, the FPI will give alarm on-site by red mechanical flag and three ultra-bright blinking LEDs.

In the case of communicable type, the FPI gives alarm on-site as well as send the data to the SCADA system by 2G/3G/4G networks.

 

The illustration below provides a basic of a communicable system.


SNOVA EFI Advantage:

The main aim of Overhead Line Fault Passage Indicator is to reduce the manual efforts to identify the fault type and location in power distribution networks. There is a significant reduction in the time, effort and manpower required for identifying faults.




Contact Supplier

Mr. Andrewmao CEO Chat Now
Telephone
86-13570657698-8621065
Mobile
86-13570657698
Fax
86-13570657698-8618303
Address
Xiangzhou district Zhuhai,Guangdong
Whatsapp
8613570657698

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Power Accessories
Categories
Hi~