Grounding Fault Sensor and Current  Short Circuit Indicator
Grounding Fault Sensor and Current  Short Circuit Indicator
Grounding Fault Sensor and Current  Short Circuit Indicator
Grounding Fault Sensor and Current  Short Circuit Indicator

Grounding Fault Sensor and Current Short Circuit Indicator

USD $1 - $2 /Piece

Min.Order:1 Piece

Supply Ability:
10000 Piece / Pieces per Month
Port:
shenzhen
Payment Terms:
T/T
Delivery Detail:
15 days

Quick Details View All >

Brand Name:
SNOVA
Place of Origin:
China
Model Number:
SNV-EKL3.2

Zhuhai City Snova Technology Co., LTD

Business license
Business Type: Manufacturer
Zhuhai Guangdong China
Main Products: Earth Fault Indicator ,Cable Fault Indicator ,Overhead Line Ground Fault Indicator ,Short Circuit and Earth Fault Indicator ,Cable Temperature and Faults Sensor ,Industrial Dehumidifier ,Temperature and Humidity Controller ,Fault Passage Indicator ,Remote communication terminal ,Smart grid system

Product Details

SNV-EKL3.2 Earth fault and short circuit indicator

 

Description

 

 SNV-EKL3.2 Earth fault and short circuit indicator, it Widely used in various ring cabinets, high-voltage switch-gear and cable branch box in power system, can accurately and reliably detect the fault section and fault type of power grid. The use of Earth fault and short circuit indicator is an efficient way to check cable fault, and is an effective way to improve the operation level of distribution network and the efficiency of fault handling. The design uses electromagnetic induction, photoelectric conversion, signal optical fiber transmission and single chip microcomputer control technology to make fault alarm with high accuracy and strong anti-interference ability.

Equipped with fault remote transmission port, suitable for distribution network automation;  Battery low power alarm indication; Low-power design, high-capacity lithium battery power supply, long battery life (more than 8 years); external structure using card or lock design, the whole machine is easy to load and unload.

 

Function character

1) Intelligent detection of short-circuit and ground fault and through the corresponding LED indicator on the panel to indicate.

2Display Monitor panel designed with button, it is convenient for reset/or test.

3It can set The pulse width time(Response time) of fault current for preventing incorrect fault indication caused by surge current.

4It can set the reset time.

5It can set the short circuit alarm current via the Dip on short circuit sensor

6It can set the earth fault alarm current via the Dip on display unit monitor.

7It can reset and detect the remote fault indication device remotely.

8It can provide switch volume for external devices through remote relay contact.

9Remote fault indicating can be made by external devices.

10Low battery display and alarm

Function description

1) short circuit alarm indicating: when short circuit sensor detected a short circuit fault current, when the current is greater than or equal to the setting value, then the short circuit sensor send alarm signal to monitor panel through fiber. And the monitor will display the alarm signal, the short circuit fault LED will be flash.

2) Earth fault alarm indicating:  when the earth fault sensor detected a earth fault current, when the current is greater than or equal to the setting value, then the earth fault sensor send alarm signal to monitor panel through cable. And the monitor will display the alarm signal, at same time, the earth fault LED will be flash.

3) Battery low voltage alarm indicating: the monitor use the battery to supply power. When the battery voltage is lower than the min. working voltage 2.7V, then the Low voltage alarm led will flash.

4)Automatic reset:  After the indicator alarm the fault, if there are without manual reset it, when the time reach our Reset time setting, indicator will automatically reset.

5) Manual Reset:  After the indicator alarm the fault, user can press the button  reset/test to reset it.

6)Remote Reset: During indicator indicating fault, Through the pin 11-12 back of the monitor, connect the remote button to control the indicator reset.

7)Remote Test:  During indicator on normal condition, Through the pin 11-12 of the monitor, connect the remote button to operate simulation test.

8) Remote indicating fault: Connect an External Lamp on the pin 9-10, when the indicator indicating fault, the External blink at same time, then achieved long distance indicating fault.

9) Remote upload SCADA: connecting connect pin13-14, or Pin13-15, when indicator indicating fault, A signal will be upload to SCADA.


Technology parameter


Voltage grade

3-40.5KV


Battery life

8year

Frequency

50HZ/60HZ

Low voltage alarm of battery

2.7V

Short circuit alarm current

 (7 levels)

200/250/300/400/500/600/1000A

Short circuit sensor fiber length

4meter, or customized

Earth fault alarm current 

(6 levels)

10/20/30/40/50/60A ,or customized

Earth fault sensor cable length

5 meter,or customized

Reset time

(4 levels)

4H/8H/24/36H

Load fluctuation and escape pulse time setting

Short circuit

40/60/80/160ms

(4 levels)

Rated frequency withstand voltage

2KV/1min

Earth fault

Relay contact capacity

95W

work environment

Temperature

-40℃~+60℃

Alarm current accuracy

±10%

Humidity

≤95%RH

Working power

ER17505

battery

3.6V/3500mAh

Use for cable diameter

Short circuit CT

(Fiber, Type S

A

Ф20mm~40mm,

Normally

B

Ф300mm~70mm customized

Working current

Standby state

10μA

Earth fault sensor

(Cable, type E)

A

Ф60mm~100mm

Normally

Working state

1mA

Indicator protection level

Monitor panel

IP 40

B

Ф80mm~130mm

Customized

Sensor CT

IP 67



Contact Supplier

Mr. Andrewmao CEO Chat Now
Telephone
86-13570657698-8621065
Mobile
86-13570657698
Fax
86-13570657698-8618303
Address
Xiangzhou district Zhuhai,Guangdong
Whatsapp
8613570657698

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Power Accessories
Categories
Hi~