Grounding fault indicator SNV-EFI V1
Grounding fault indicator SNV-EFI V1
Grounding fault indicator SNV-EFI V1

Grounding fault indicator SNV-EFI V1

USD $10 - $300 /Piece

Min.Order:1 Piece

Supply Ability:
10000 Piece / Pieces per Month
Port:
shenzhen
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other
Delivery Detail:
15 days

Quick Details View All >

Brand Name:
SNOVA
Place of Origin:
China
Model Number:
SNV-EFIV1

Zhuhai City Snova Technology Co., LTD

Business license
Business Type: Manufacturer
Zhuhai Guangdong China
Main Products: Earth Fault Indicator ,Cable Fault Indicator ,Overhead Line Ground Fault Indicator ,Short Circuit and Earth Fault Indicator ,Cable Temperature and Faults Sensor ,Industrial Dehumidifier ,Temperature and Humidity Controller ,Fault Passage Indicator ,Remote communication terminal ,Smart grid system

Product Details

Description

SNV-EFI earth fault indicator, it Widely used in various ring cabinets, high/ Medium or low -voltage switch gear and cable branch box in power system, can accurately and reliably detect the fault section and fault type of power grid in the Low/medium voltage network. The use of cable type grounding fault indicator is an efficient way to check cable fault, and is an effective way to improve the operation level of distribution network and the efficiency of fault handling.

The design uses electromagnetic induction, and single chip microcomputer control technology to make fault alarm with high accuracy and strong anti-interference ability. Equipped with fault remote transmission port, suitable for distribution network automation; Battery low power alarm indication; Low-power design, high-capacity lithium battery power supply, long battery life (more than 10 years); external structure using card or lock design, the whole machine is easy to load and unload.


Function character

1)        Intelligent detection of ground fault and through the corresponding LED on the display unit to indicate fault.

2)  Display unit designed with button, it is convenient for reset or test.

3)  The pulse width time of fault current can be set to prevent incorrect fault indication caused by surge current.

4)  It can reset and detect the remote fault indication device remotely by Scada or press key.

5)  It can provide switch volume for external devices through remote contact.

6)  It can choose the reset time after fault happen (when purchase, it need to tell factory to set,default 8hours).

7)  Remote fault indicating can be made by external lamp.

8)  Earth fault alarm current,Multi-level can be settable through a DIP inside of the display nit(optional)

9)        Low battery display and alarm test through press the “Test/reset” key by 3seconds.

10)  Battery can be changeable conveniently.

 

 Function description

1) Earth fault alarm indicating: when the earth fault sensor detected an earth fault current, and the current is bigger than equal to or equal to the setting value, then the earth fault sensor send a signal to display unit through electric cable. And the display unit will display the alarm signal, at same time, the earth fault LED will be blinking.

2)Battery low voltage alarm indicating: the display unit use the battery to supply power. When we press the “Test” button,3seconds time: If the battery voltage is lower than the Min. working voltage 2.5V, then the Battery

Level Led will be blinking 5 times; If battery voltage is normal, then only blink 1 times. 

3) Automatic time reset: After the indicator alarm the fault, if there are without manual reset it, when the time reach our reset time setting, indicator will automatically reset.

4) Manual reset: After the indicator alarm the fault, user can press the button “ reset/test” in a short time to reset it.

5) Automatic Low voltage reset: Through inputting AC110-240V power to the pin 10,11 on the PCB in the display unit, when fault indicating, at same the voltage powered off. when the voltage recover and power on again, then indicator will be reset immediately via low voltage.

6) Out side AC110-240V power supply energy for display unit. It use the same as voltage of the “voltage reset” via pin 10,11.

7) Remote(Scada) reset/test: through short connect the pin 3,4, then indicator will be run the reset/test process, and Led will be blinking. *Connect the pin 3,4 by short time(1second), then it will be reset indicator. * connect the pin3,4 by a long time(3seconds), then it will be test indicator.

8)Remote indicating: Through connect the pin 5,6 to the external lamp , then it will be indicate fault when any phase alarm fault.

 

Technology parameter

Pin 1-2 : sensor connect

Pin 3-4 : Remote Reset/ test

Pin 5-6: External indicating LED

Pin 7-8: NC relay , Pin 7-9: NO relay

Pin 10-11: power supply and voltage reset (AC110-240V)


Contact Supplier

Mr. Andrewmao CEO Chat Now
Telephone
86-13570657698-8621065
Mobile
86-13570657698
Fax
86-13570657698-8618303
Address
Xiangzhou district Zhuhai,Guangdong
Whatsapp
8613570657698

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Power Distribution Equipment
Categories
Hi~