Overhead line fault passsage  indicator working principle
Overhead line fault passsage  indicator working principle
Overhead line fault passsage  indicator working principle
Overhead line fault passsage  indicator working principle
Overhead line fault passsage  indicator working principle

Overhead line fault passsage indicator working principle

USD $1 - $30 /Set

Min.Order:1 Set

Supply Ability:
5000 Set / Sets per Month
Port:
Shenzhen
Payment Terms:
T/T D/P D/A Other
Delivery Detail:
7 days

Quick Details View All >

Brand Name:
SNOVA
Place of Origin:
China
Model Number:
SNV-308.1

Zhuhai City Snova Technology Co., LTD

Business license
Business Type: Manufacturer
Zhuhai Guangdong China
Main Products: Earth Fault Indicator ,Cable Fault Indicator ,Overhead Line Ground Fault Indicator ,Short Circuit and Earth Fault Indicator ,Cable Temperature and Faults Sensor ,Industrial Dehumidifier ,Temperature and Humidity Controller ,Fault Passage Indicator ,Remote communication terminal ,Smart grid system

Product Details

Overhead line fault passsage  indicator working principle  

TypeSNV308 Indicator

Description

SNV Indicators suitable for overhead lines with a 50KV below four remotes short circuit &Earth fault indicator, through measuring the current of a cable, to judge the fault on the power lines according to the change of current, grounding fault, and the fault state, real time current, battery voltage and other information is uploaded to the remote server, which provides reliable data for the various types of fault diagnosis and location of overhead lines

Character:

real-time sampling of current per cycle       

ultra low power real-time sampling

l When line current value≧5A,CT can supply meet the indicator power requirement

Sampling accuracy5-20A±1.5A20-800A±3%

Sensor factory automatic calibration, to ensure consistency

intelligent motor control flop

Support remote, telemetry, remote control, remote adjust

Function character

a. real time measurement of three-phase on line current

b. Detection and judgment of short circuit fault

a) support the determination of the set threshold, fault current, short circuit fault

b) supports the determination of a set of mutated incremental currents for short-circuit faults

c) supports the determination of the percentage of short circuit faults that can be set by the percentage of mutated currents

d) support for reclosing identification

c. Detection and judgment of ground fault

d. Data Upload function

a) periodically upload real-time online current, zero sequence current, and battery voltage

b) Upload the fault status, the fault elimination status and the fault current value in real time

e. Parameter setting

a) Available to change the parameter setting through Web server.

b) Available to change and set the parameter though remote setting control PDA

c) Support RS232 port for parameter modification and maintenance

f. Support setting controller (PDA)

a) Available reading and change setting parameter

b) PDA can read Indicator sensor state , Real time line current, battery voltage data.

c) PDA can simulate the online fault test through setting Indicator’s parameter.

g. Intelligent motor control flop to red flag

h. Six three-color fault indicating led(red, green, blue)

i. One yellow state led light

j. Support line CT power charge for battery

k. Support timing reset, power on auto reset, remote reset

l. can be efficiently mounted and unloaded

m. The structure parts are made of antirust and anticorrosion material

n. In waking up state(wireless setting model),During 7 minutes, without operate, there will be auto reset.(Tips: in waking up state, FI prohibited fault test)

Function display

Flag state

1) Normally, Flag is on blanket position. Every 3hour, Flag will reset one times for avoiding un fault turn to red flag.

2) When short circuit fault happen, it will turn to red flag state; After reach reset time or when the line current restore, Fault indicator will turn back to blanket state;

3) when the earth fault happen, it will turn to red flag state. It will be automatically turn back blanket state when line power off and current restore, or wait until reach reset time.

 

Fault indicating Led light

1) short circuit permanent fault indicating: Six 3-color led will shine red color, and four times, every 2 secondAnd turn to red flag at same time

2) short circuit temporary fault indicating: Six 3-color led will shine green color, and four times, every 2 secondAnd turn to red flag at same time

3) Earth Fault indicatingSix 3-color led will shine Blue color, and four times, every 2 second. And turn to red flag at same time.

 

yellow state Led light

Battery voltage too lowShine 1 time, every2second

Battery voltage low  shine 2 time, evey2second

Wireless setting state:   shine 4 times, every 2 second


  

 

Contact Supplier

Mr. Andrewmao CEO Chat Now
Telephone
86-13570657698-8621065
Mobile
86-13570657698
Fax
86-13570657698-8618303
Address
Xiangzhou district Zhuhai,Guangdong
Whatsapp
8613570657698

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Power Distribution Equipment
Categories
Hi~