Acrel 2 Way Incoming Lines AC Din Rail Multi Circuit Energy Meter AMC16Z-ZA For IDC Data Center Monitoring Power Distribution Monitoring Solution
USD $91 - $130 /Piece
Min.Order:1 Piece
AMC16Z-ZA Dual-circuit Data Center Energy Meter
● Monitoring: Dual Independent AC Incoming Circuits 3-phase (For Data Center)
● Measurement: Voltage, Current, Frequency, Active Power, Reactive Power, Power Factor and etc
● Power Quality: 2nd~63rd&Total Harmonic, Current&Voltage Unbalance and etc
● Communicaiton: RS485 (MODBUS-RTU)
● Rated Voltage: 220~264Vac L-N
● Rated Current: 1(6)A AC (via CTs)
● Standard&Certificate: CE; IEC; LVD
1. Function Overview
Function | Description |
Measurement(Common) | Three-phase AC kWh, kVarh, Active Power, Reactive Power, Current, Voltage, Power Factor, Apparant Power, Frequency, Zero ground voltage, neutral line current |
Measurement(Power Quality) | total harmonic content (THD), 2-63 harmonics, current and voltage unbalance degree, current K coefficient (KF), voltage crest coefficient (CF),telephone waveform factor (THFF), peak voltage, voltage and current sequence quantity |
Temp.&HumidityMonitoring | Tempeatrue Monitoring Range: -40℃~+99℃ Humidity Monitoring Range: 20%~90% |
Leakage Current | 2-channel Leakage Current Measurement |
Accuracy | Electrical Parameter Metering Accuracy: Voltage/current level 0.2, active power/electric energy level 0.5,reactive power/electric energy level 1
Temperature Metering Accuracy: ±1℃; Temperature Metering Accuracy: ±5% |
Communication | RS485 Interface (MODBUS-RTU protocol) |
DO(Swtich Output) | 2-channel DO (Digital Output); 3A 250VAC/3A 30VDC |
DI(Swtich Input) | 6-channel DI (Digital Input); dry contact |
2. Main Parameters
Parameter | Description&Value | |
Voltage Input | Rated Voltage | 3x220~264Vac L-N |
Reference Frequency | 45~65Hz | |
Current Input | Rated Current | 3x1(6)A AC (via CTs) |
Power Supply | Source from | Voltage Input (Voltage signal input for both measurement and power supply) |
Installation | DIN-rail | 35mm standard DIN-rail Installation |
Phase Wiring | 3P4W | 3-phase 4-wire |
Safety | Insulation | All terminals and the insulation resistance between the conductive pieces not less than 100MΩ |
Withstand voltage | A-way voltage and current signal, B-way voltage and current signal, switch output and other ports should meet AC2kV 1min in pairs, the switch input and other ports should meet ac0.5kv 1mim, leakage current should be less than 2mA, no breakdown or flashover |
3. Environment
Condition | Description&Value |
Temperature | Operating Temperature: -20℃~+55℃; Storage Temperature: -40°C ~+70°C |
Humidity | ≤95%RH,no condensation,without corrosive gas |
Altitude | ≤ 2000m |
PIN/Terminal Overview of AMC16Z-ZA
Main Power Wiring Diagram of AMC16Z-ZA
Application in Data Center