The AKS 4100/4100U liquid level sensor is designed specifically to measure liquid levels in a wide range of refrigeration applications. The AKS 4100/4100U liquid level sensor is based on a proven techhology called Time Domain Reflectometry (TDR) or Guided Micro Wave. AKS 4100/4100U liquid level sensor can be used to measure the liquid level of many different refrigerants in vessels, accumulators, receivers, standpipes, etc. The electrical output is a 2-wired, loop powered 4 – 20 mA output signal, which is proportional to the refrigerant liquid level. AKS 4100/4100U in a cable version is suitable for HCFC, Non flammable HFC and R717 (Ammonia), and differing lengths from 800 mm / 31.5 in. and up to 5000 mm / 197 in.. The coaxial version of AKS 4100/4100U is designed for use with R744 (CO2), HCFC, Non flammable HFC and R717 (Ammonia). The AKS 4100/4100U coaxial version should always be used for marine applications for all refrigerant types. The AKS 4100/4100U cable version should NOT be used for CO2 or marine applications. Dust, foam, vapour, agitated surfaces, boiling surfaces, changes in density or in the dielectric constant , εr, for the liquid have no influence on the AKS 4100/4100U performance. Oil accumulated in the bottom of a standpipe will not disturb the liquid level signal and it is not necessary to remove AKS 4100/4100U for cleaning after oil has been drained out of the standpipe.
Features
• Approved and qualified by Danfoss for refrigeration applications • One product covering several probe lengths (cable version) • A single product for all commonly used refrigerants (cable version) • Cable version requires less top-end clearance for installation and service • Proven operation with all refrigerants in combination with oil. • No need to clean cable version when fully covered by oil. • The cable version is very compact and easy to handle, ship, install and use with different lengths and refrigerants • Changes of the liquid dielectric constant (εr) do not affect operation. • 5000 mm / 197 in. probe length with cable version • 2-wire loop powered; no separate transformer needed. Please Note: AKS 4100/4100U can be connected directly to Danfoss EKE 347 liquid level controller and thus be powered from EKE 347. If used together with Danfoss EKC 347 liquid level controller, a 14 – 30 V DC supply is required. • Multi language HMI. Level and setting readout in mm,cm,m (ft, in.) Language HMI versions: - English (default), German, French, Spanish - English (default),Japanese, Chinese Russian