Danfoss NRVA15/20-25/32-NRVA40/50 check valve
1100 - 2600 /Piece
Min.Order:1 Piece
Guangzhou Sizhuo Trading Co. Ltd.
Danfoss NRVA15/20-25/32-NRVA40/50 check valve introduce
Check valve type NRVA can be used in liquid, suction and hot gas lines in refrigeration and air conditioning plant with ammonia. NRVA can also be used in refrigerating systems with fluorinated refrigerants. When the NRVA is used in liquid lines where cold, thick oil or impurities may be present, it is recommended that the standard spring be replaced by a special spring. See ordering table.
Features • Ensures correct direction of flow. • Valve housing made of steel. • Available for 40 bar g / 580 psig working pressure. • Large range of flanges with connection dimensions in accordance with standards: DIN, ANSI, SOC, SA and FPT. • Fitted with damping piston that makes the valves suitable for installation in lines where pulsation can occur, e.g. in the discharge line from the compressor. • Classification: DNV, CRN, BV, EAC etc. To get an updated list of certification on the products please contact your local Danfoss Sales Company
Design Connections There is a very wide range of connection possibilities with NRVA check valves: • Welding, DIN (2448) • Welding, ANSI (B 36.10) • Welding socket, ANSI (B 16.11) • Solder connection, DIN (2856) • Solder connection, ANSI (B 16.22) • FPT internal thread, NPT (ANSI/ASME B 1.20.1) Gaskets: Do not contain asbestos. Valve cone: The valve cone has a teflon tightening ring. Teflon tightening ring renders perfect sealing at a minimum closing force.