TRICONEX 2481
1051 - 2270 /Piece
Min.Order:1 Piece
Temporal Ming sheng automation equipment co., LTD
Brand:TRICONEX
Type:2481
Origin: the United States
Warranty: 365 days
Colour: new/used
Shipping method: Courier delivery
Module of PLC, DCS, ESD system card, the card is a vibration monitoring system, steam turbine control system module, the advantages of the gas generator spare parts brand: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts
Our main products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, mechanical, electronic manufacturing, automobile manufacturing, plastic machinery, electric power, water conservancy, water treatment/environmental protection, boiler heating, energy, power transmission and distribution and so on.
All steps in the program must contain valid entries. The default values are listed along with any adjustment ranges, where applicable. If an invalid entry is made, the control displays an invalid entry message. If ENTER is pressed, the control displays the program step again so a valid entry can be made.
Program Blocks Figure 4-3 shows the 15 program columns. To program the control, simply step through the blocks as described above and configure the control features for the desired application. The first nine program columns must be programmed for every installation. The remaining six columns contain optional features which can be selected if desired. The 13 columns and their basic functions are described in detail below. Required Configuration Blocks: • Turbine Start—to configure start mode, idle/rated, and auto start sequence settings; • Speed Control—to configure MPU or PROX PROBE information and speed control dynamics settings; • Speed Setpoint Values—to configure speed setpoints, overspeed trip setpoint, remote speed setting control and critical speed avoidance bands; • Operating Parameters—to configure the unit for generator application and to use the local /remote function; • Extraction / Admission Control—to configure extraction/admission control information; • Driver Configuration—to configure driver outputs; • Turbine Performance Values—to configure unit ratio and limiting logic and steam map; • Analog Inputs—to configure analog input options; • Contact Inputs—to configure contact input options; Optional Configuration Blocks: • Function Keys—to configure F3 and F4 function keys options; • Auxiliary Control—to configure auxiliary control information; • Cascade Control—to configure cascade control information; • Readouts—to configure analog readout options; • Relays—to configure relay options; • Communications—to configure Modbus communication options. Each of the program blocks are described in detail below. Figure 4-3 can be referred to for a graphical program block reference. After a column has been configured and the display is back at the top of the column, use the left or right arrow keys to select the next column to configure or check. All control program questions will be displayed on the top line of the display; all entries made will be displayed on the lower line of the display.
At the beginning of each column the control will display the header, pushing the down arrow will access the column. The program blocks (Figure 4-3) contain information detailing each question and/or 505E program configuration option. Each question/option shows the default (dflt) value and the adjustable range of that parameter (shown in parentheses). In addition, any additional constraints on the configuration are shown in italics following the description. There is a program mode worksheet in the appendix of this manual that should be completed/filled in and used as a guide for your particular application. This worksheet can also be used for future reference to document your application program.