TRICONEX 3101

TRICONEX 3101

1051 - 2270 /Piece

Min.Order:1 Piece

Supply Ability:
159 Piece / Pieces per Month
Payment Terms:
T/T
Delivery Detail:
1 days

Quick Details View All >

Brand Name:
TRICONEX
Place of Origin:
China
Model Number:
TRICONEX 3101

Temporal Ming sheng automation equipment co., LTD

Business license
Main Products: ABB、GE、MOTOROLA、BENTLY、EMERSON、HIMA、TRICONEX

Product Details

Brand:TRICONEX

Type:3101

Origin: the United States

Warranty: 365 days

Colour: new/used

Shipping method: Courier delivery

Module of PLC, DCS, ESD system card, the card is a vibration monitoring system, steam turbine control system module, the advantages of the gas generator spare parts brand: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts

Our main products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, mechanical, electronic manufacturing, automobile manufacturing, plastic machinery, electric power, water conservancy, water treatment/environmental protection, boiler heating, energy, power transmission and distribution and so on.

Turbine Start Block When this header appears in the display, press the down arrow key to configure this block or press a left or right arrow key to select another block to configure. MANUAL START? dflt= NO (Yes/No) Select YES followed by the ENTER key to configure a manual start mode. When configured for a manual start mode, the operator controls the turbine speed from zero up to the minimum control speed using an external tripthrottle valve. The Manual Start Sequence would be: Push RUN. The actuators automatically move to max position. Lastly, the operator slowly opens the trip-throttle valve until the governor takes control. AUTOMATIC START? dflt= NO (Yes/No) Select YES followed by the ENTER key to configure an automatic start mode. When configured for an automatic start mode, the 505E controls the turbine speed from zero up to the minimum control speed. The Automatic Start Sequence would be: Operator opens the T&T valve, then push RUN. The HP valve limiter opens automatically until the governor takes control. SEMIAUTOMATIC START? dflt= NO (Yes/No) Select YES followed by the ENTER key to configure a semiautomatic start mode. When configured, the 505E’s HP limiter must be manually opened by the operator, slowly, to open the control valve and bring the turbine speed from zero up to the minimum control speed. The Semi-automatic Start Sequence would be: Open the T&T valve, then push RUN. The valve limiter must then be raised by the operator until governor takes control. (One of the three start modes must be selected before the unit will run) RATE TO MIN ( RPM/SEC ) dflt= 10.0 (0.01, 2000) Enter the speed setpoint acceleration rate to minimum followed by the ENTER key. This is the rate the setpoint moves from zero to the lowest controlling speed on a start command (assuming the turbine is at zero speed). The minimum controlling speed will be either ‘idle’ if idle/rated is used or ‘low idle’ if the auto start sequence is used. If neither of these startup features is used, the min speed will be the minimum governor speed setpoint. HP VALVE LIMITER RATE ( % / SEC ) dflt= 5.0 (0.01, 25) Enter the HP Valve Limiter Rate, in percent per second, followed by ENTER. This is the rate at which the HP valve limiter moves when RUN is selected or when the limiter setting is changed through open/close commands. When using a semiautomatic or automatic start, this setting should be very slow—typically less than 2 %/sec. When using a manual start, this setting is less critical and can be left at the default of 5 % / sec. USE IDLE/RATED ? dflt= NO (Yes/No) Select YES followed by ENTER if this function is desired. If NO, skip to ‘Use Auto Start Sequence’. 

If YES is selected, the control will ramp from a programmable Idle speed to a programmable Rated speed setpoint when Rated is selected through keypad, Modbus or external switch. IDLE SETPT (RPM) dflt= 1000 (0.0, 20000) Enter the Idle Speed setpoint desired followed by the ENTER key. This is the lowest speed control setpoint when using the Idle/Rated function. RATED SETPT (RPM) dflt= 3600 (0.0, 20000) Enter the Rated Speed setpoint desired followed by the ENTER key. This is the speed control setpoint that the unit accelerates to when using the Idle/Rated function. (Must be greater than or equal to the ‘Minimum Governor Speed’ Setting) IDLE/RATED SETPT RATE ( RPM/SEC ) dflt= 5.0 (0.01, 2000) Enter the Idle/Rated rate (rpm/second) followed by ENTER. This is the at which the speed setpoint moves between Idle and Rated speed setpoints when using the Idle/Rated commands.

Contact Supplier

Ms. Chat Now

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Other Electrical Equipment
Categories
Hi~