IS220PDOAH1A 3364940CSP2

IS220PDOAH1A 3364940CSP2

USD $1063 - $2052 /Piece

Min.Order:1 Piece

Supply Ability:
164 Piece / Pieces per Month
Payment Terms:
T/T
Delivery Detail:
1 days

Quick Details View All >

Brand Name:
GE
Place of Origin:
China
Model Number:
IS220PDOAH1A 3364940CSP2

Temporal Ming sheng automation equipment co., LTD

Business license
Main Products: ABB、GE、MOTOROLA、BENTLY、EMERSON、HIMA、TRICONEX

Product Details

Brand: GE

Type: IS220PDOAH1A 3364940CSP2

Origin: the United States

Warranty: 365 days

Colour: new/used

Shipping method: Courier delivery

Module of PLC, DCS, ESD system card, the card is a vibration monitoring system, steam turbine control system module, the advantages of the gas generator spare parts brand: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts of our products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, mechanical, electronic manufacturing, automobile manufacturing, plastic machinery, electric power, water conservancy, water treatment/environmental protection, boiler heating, energy, power transmission and distribution and so on.

Run Mode Front Panel Keys For a detailed description of each 505E key functionality see Chapter 1. Of the thirty front panel keys, not all are active at all times in the Run mode. However, from the front panel, the keys that are active will be apparent since there is immediate display feedback when an active key is pressed. When a respective “Hot” key (Aux, Casc, kW, etc.) function is not programmed, a ‘Function Not Programmed’ message will be appear if the key is pressed. The following are generalizations when determining what keys will function: • The ADJUST UP/DOWN keys are active when a setpoint is displayed and the setpoint is not in a remote control or tracking mode. • The ENTER key is active whenever the ADJUST UP/DOWN keys are active. This is when the setpoint is shown on the display and the setpoint is not in remote control or tracking mode. • The YES/NO keys are active whenever a status indication is shown on the display and an enable/disable function is valid. • The CAS, AUX, kW, and RMT keys are only active if the function is configured in the Program Mode. • The SPEED, ACTR, LMTR, CONT, EXT/ADM, and DYN keys are always active. • The PRGM, RUN, STOP, RESET, and ALARM keys are always active. • The F3 and F4 function keys are only active if they are configured. • The OVERSPEED TEST ENBL is conditionally active (only active when OSPD test is permissible).

Starting Procedures Refer to the turbine manufacturer’s operating procedures for complete information on turbine start up, and Chapter 3 of this manual for a step by step procedure, depending on the start mode selected. The following is a typical startup procedure: WARNING The engine, turbine, or other type of prime mover should be equipped with an overspeed shutdown device to protect against runaway or damage to the prime mover with possible personal injury, loss of life, or property damage. The overspeed shutdown device must be totally independent of the prime mover control system. An overtemperature or overpressure shutdown device may also be needed for safety, as appropriate. 1. Press the RESET key to clear all alarms and trips and increase the LP Valve Limiter to 100%. If the 505E’s ‘RESET CLEARS TRIP’ setting is programmed “YES”, the 505E’s shutdown relay will reset or energize upon pressing the RESET key after a shutdown. If the ‘RESET CLEARS TRIP’ setting is programmed “NO”, the 505E’s shutdown relay will reset or energize upon pressing the RESET key ONLY after all trip conditions are cleared. 2. Press the RUN key to initiate the selected start-up mode. The front panel display will automatically jump to the SPEED screen (if auto or manual start is programmed) or to the LMTR screen (if semiauto start is programmed). If a semi-automatic start mode is configured, the valve limiter must be manually increased to open the control valve. • A ‘Start Perm Not Closed’ alarm will be issued if the application is using a Start Permissive contact input and this contact input was not closed when the RUN command was issued.

Contact Supplier

Ms. Chat Now

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Other Electrical Equipment
Categories
Hi~