5SHY3545L0016 3BHB020720T0002 3BHE019719R0101 GVC736BE101

5SHY3545L0016 3BHB020720T0002 3BHE019719R0101 GVC736BE101

1043 - 2263 /Piece

Min.Order:1 Piece

Supply Ability:
152 Piece / Pieces per Month
Payment Terms:
T/T
Delivery Detail:
1 days

Quick Details View All >

Brand Name:
ABB
Place of Origin:
China
Model Number:
5SHY3545L0016 3BHB020720T0002 3BHE019719R0101 GVC736BE101

Temporal Ming sheng automation equipment co., LTD

Business license
Main Products: ABB、GE、MOTOROLA、BENTLY、EMERSON、HIMA、TRICONEX

Product Details

Brand:ABB

Type:5SHY3545L0016 3BHB020720T0002 3BHE019719R0101 GVC736BE101

Origin: the Swiss

Warranty: 365 days

Colour: new/used

Shipping method: Courier delivery

Module of PLC, DCS, ESD system card, the card is a vibration monitoring system, steam turbine control system module, the advantages of the gas generator spare parts brand: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts

Our main products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, mechanical, electronic manufacturing, automobile manufacturing, plastic machinery, electric power, water conservancy, water treatment/environmental protection, boiler heating, energy, power transmission and distribution and so on.

If the 505E is programmed to control unit load using turbine valve positions, the 505E calculates load based on the valve positions at the time the generator breaker is closed. The valve positions at this point are considered to be zero load. In a typical application, where inlet and exhaust pressures are at rated levels when the generator breaker is closed, this zero load calculation allows unit load to be accurately sensed and controlled. Speed Setpoint The Speed PID’s setpoint may be adjusted from the 505E keypad, external contacts, Modbus commands, or through a 4–20 mA analog input. A specific setpoint setting can also be directly entered through the 505E keypad or Modbus communications. The Cascade PID also directly controls this setpoint when it is used. The speed setpoint range must be defined in the program mode. Program settings ‘Min Governor Speed Setpoint’ and ‘Max Governor Speed Setpoint’ define the normal operating speed range of the turbine. The speed setpoint cannot be raised above ‘Max Governor Speed Setpoint’ setting unless an Overspeed Test is performed. Once the speed setpoint is taken above the ‘Min Governor Speed Setpoint’ setting, it cannot be varied below this setting again unless the Idle/Rated ramp-to-Idle command is selected or a Controlled Stop is selected.

Once turbine speed is equal to or greater than the ‘Min Governor Speed Setpoint’ setting, the speed setpoint may be adjusted through discrete raise and lower commands. When a raise or lower speed command is issued, the setpoint moves at the programmed ‘Speed Setpoint Slow Rate’. If a speed raise / lower command is selected for longer than three seconds, the speed setpoint will then move at a faster rate which is three times the speed setpoint slow rate. The speed setpoint slow rate, fast rate delay, and fast rate can all be adjusted in the Service mode. The shortest length of time a setpoint will move for an accepted raise or lower command is 120 milliseconds (240 milliseconds for a Modbus command). If the speed setpoint rate is programmed for 10 rpm/sec, the smallest increment it will move is 1.2 rpm (2.4 rpm for Modbus). The speed setpoint may be set to a specific level, by directly entering a setpoint value through the 505E keypad or Modbus communications. To enter a specific setpoint from the 505E keypad, press the SPEED key to view the speed control screen, press the ENTER key, enter the setpoint level desired, then press the ENTER key again. If a valid number was entered, the setting will be accepted and the Speed setpoint will ramp to the “entered” setpoint level. If an invalid number is “entered” the setting will not be accepted and the 505E’s screen will momentarily display a value out-of-range message. After a valid setpoint value is entered and accepted, the setpoint will ramp at the speed setpoint slow rate (defaulted setting) to the newly entered setpoint value. The rate that the setpoint ramps at when a specific value is entered may be changed from its defaulted value by changing the ‘Entered’ rate setting under the Service mode’s “Speed Control Settings” header.

Contact Supplier

Ms. Chat Now

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Other Electrical Equipment
Categories
Hi~