DK8-BX10 Stainless Steel Lightning Arrester 1.6 Meter Copper 7.5kg ESE Lightning Protection Rod lighting rod
Negotiable
Min.Order:1
Hot Sale Rod Lightning Arrester Lightning Rod 200kA ESE Stainless Steel Copper Lightning Arrester
Active Lightning Protection System Lightning Rod Surge Lightning Protection Product
outdoor lightning rod lightning Conductor Arrester Lightning Lightn Protect
Lightning Protection System Air Terminal Lightning Arrester ESE Lightning Rod System
Introduction
DK8-BX10 Stainless Steel Lightning Arrester 1.6 Meter Copper 7.5kg ESE Lightning Protection Rod is composed of the following sections:
1) Main receiving lightning point: It is made up of copper alloy. It connects from down-conductor to receiving lightning point forming a uninterrupted path to convey the lightning current to the ground. It is fixed in a lightning rod(tower)pole more than 2 meters high.
2) Discharge strike spark board; generate spark.
3) Active discharge point: collect the electric energy.
4) Waterproof stainless steel box: store the electrostatic field energy.
5) Side point of receiving lightning: it is made up of stainless steel. It can convey surrounding lightning current to the ground directly.
6) Stainless steel sleeve, install fasteners, down lead connection point.
Technical Parameter
Item | DK8-BX10 ESE Lightning Protection Rod | DK-BG10 ESE Lightning Protection Rod | DK-BX10 ESE Lightning Protection Rod |
Discharge Capacity | 200kA (10/350μs) | 300kA (10/350μs) | 300kA (10/350μs) |
Amplitude Damping Radio | ≥70% | ≥82% | ≥82% |
Gradient Damping Multiplying Radio | ≥48 | ≥35 | ≥35 |
early start time | 60μs | 60μs | |
Currents Limiting Impedance Value | ≤3Ω | ≤2Ω | ≤2Ω |
Earthing Resistance | ≤10Ω | ≤10Ω | ≤10Ω |
Wind Load | ≤48m/s | ≤48m/s | ≤48m/s |
Height(m) | 1.8M | 1.8M | 2.1M |
Weight(kg) | 7.5kg | 4.0kg | 10.6kg |
Down Conductor | Steel plate or steel rod which diameter is more than 8mm | Steel plate or steel rod which diameter is more than 8mm | Steel plate or steel rod which diameter is more than 8mm |
Character
1) Accurate thunderbolt point.
2) Maintenance-free, no need connect additional power.
3) Activate itself only when the thunderbolt forming, completely early discharge initially.
Installation Guide
1) Please notify us the technical parameters of your lightning rod mast when ordering, so that the factory can select the right interconnection splice for you to install components successfully.
2) The thickness of lightning rod’s sleeve shall not less than 4mm, which can be used as a down-conductor. There shall be two points symmetric connecting the earth electrode.
3)When the structure’s lightning protection system has more than 1 down-conductor, breaking of contact with insulation protection for each down-conductor is recommended. And the breaking of contact shall be set at 1.5~1.8m h igh f rom g round o f t he c onductor.
4) The joint between lightning rod and down-conductor shall be welded.
5) The construction order for the earth-termination system of lightning rod shall be from top to bottom. The common grounding system shall be installed first, and then come to the down-conductor, and the lightning rod is the last step.
Application Scope
Suitable for direct lightning protection of mobile communication base station, satellite station, warehouse, meteorological observatory, petrol station, airport station, military radar station, etc.
Lightning Rod Series | Signal Series SPD | lightning strike counter |
LED street light SPD | Monitoring System SPD | Antenna Feeder SPD |
Grounding Series | extension socket | CCTV canera surge protector |
Q1: What’s your advantages?