BIOBASE China Auto Hematology Analyzer BK-3100 Hematology Analyzer Machine 60T/H for Clinic and Lab
Negotiable
Min.Order:1
Model | BK-3100 | ||||||||||
Throughput | 60 samples/hour | ||||||||||
Principle | Impedance for WBC differentiation and WBC/RBC/PLT count; Colorimetric method for HGB | ||||||||||
Channels | 2 | ||||||||||
Parameters | 21 parameters(including WBC, Mid#, Lym#, Gran#, Mid%, Lym%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC,RDW-SD, RDW-CV, PLT, MPV,PDW,PCT, P-LCR, P-LCC) | ||||||||||
Histograms | 3 histograms (including WBC, RBC, PLT histograms) | ||||||||||
Sample Volume | Whole blood: 10μl, Prediluted: 20μl | ||||||||||
Calibration | Manual, auto calibration | ||||||||||
Counting Modes | Venous, capilary, prediluted | ||||||||||
Printing Model | Auto print, manual print | ||||||||||
LIS | Support Bi-directional LIS | ||||||||||
Language | Chinese, English, Spanish, French, Russian, Ukrainian | ||||||||||
Reagent | Diluent 20L, Hemolytic agent 500ml, Probe cleanser: 50ml | ||||||||||
Data Input | 9.7-inch touch screen, mouse, keyboard (optional) | ||||||||||
Output | Internal printer, support external printer | ||||||||||
Printer paper | 57*30mm | ||||||||||
Interface | 4 USB ports, network port,RS232 serial port. | ||||||||||
Storage | 100,000 results with histogram | ||||||||||
Unclog | High voltage burn, reverse high-pressure flush | ||||||||||
Work Temperature | 15-30°C | ||||||||||
Power Supply | 100~240 AC, 50/60Hz, 150VA | ||||||||||
Relative Humidity | 30﹪~85﹪ | ||||||||||
Atmospheric Pressure | 70.0kPa-110.0kPa | ||||||||||
Carry-over rate | Parameter | WBC | RBC | HGB | PLT | ||||||
CV | ≤ 1.5% | ≤ 1% | ≤ 1% | ≤ 3% | |||||||
Background | Parameter | WBC | RBC | HGB | HCT | PLT | |||||
Background | ≤ 0.3×109/L | ≤ 0.03×1012/L | ≤ 1 g/L | ≤ 0.5% | ≤ 10×109/L | ||||||
Linearity | Parameter | Measurement range | CV | ||||||||
WBC | (0.5~10.00×109)/L (10.10~99.9×109)/L | (±0.5×109)/L ±5% | |||||||||
RBC | (0.05~1.00×1012)/L (1.01~9.99×1012)/L | (±0.05×1012)/L ±5% | |||||||||
HGB | (2~70g)/L (71~300.0g)/L | (±2.0g)/L ±2% | |||||||||
PLT | (10~100×109)/L (101~999×109)/L | (±10.0×109)/L ±8% | |||||||||
Precision | Parameter | Whole blood (CV) | Pre-diluted (CV) | Measurement range | |||||||
WBC | ≤ 2.0% | ≤ 4.0% | (4.0-15.0×109)/L | ||||||||
RBC | ≤ 1.6% | ≤ 3.0% | (3.5-6.0×1012)/L | ||||||||
HGB | ≤ 1.6% | ≤ 3.0% | (110.0-180.0g)/L | ||||||||
MCV | ≤1.0% | ≤2.0% | (70.0-120.0)fL | ||||||||
PLT | ≤ 4.0% | ≤8.0% | (150.0-500.0×109)/L | ||||||||
External Size(W*D*H) | 295*467*418mm | ||||||||||
Packed Size(W*D*H) | 404*564*616mm | ||||||||||
Net weight | 19 KG | ||||||||||
Gross weight | 31KG |