Multifunctional Digital Modbus Power Meter Price
Negotiable
Min.Order:1
Three Phase Digital Panel Multifunction Watt Hour power meter power quality analyzer price
Power meter 3 phase power quality analyzer energy meter rs485 electrical network analyzer
High Accuracy RS485 Meter Communication Digital Power Meter KPM73
Multifunction Meter Digital Power Meter Price Power Quality Analyser Modbus TCP Power Monitor
Working power supply | Rated voltage | AC85~265V/DC80~300V | ||||
Rated power consumption | <3VA | |||||
Input Voltage | Rated voltage | 57.7/100V, 220V/380V, 380/660V(Customized) | ||||
Threshold value | 5V | |||||
Overload capacity | 1.2 times rated voltage, continuous operation, 2 times rated voltage, allow 10S | |||||
Power consumption | <0.75VA/phase (Rated 5A) | |||||
Measurement range | Phase voltage (LN):50~260VAC Line voltage(LL):90~450VAC | |||||
Input current | Rated current | Default 5A,Input range 1-6A;Optional 1A | ||||
Threshold value | 5A Configuration,5mA; 1A Configuration | |||||
Overload capacity | 1.2 times rated current allowed, continuous work; 20 times the rated current allowed 1 second | |||||
Power consumption | <0.75VA/phase(Rated current 5A);<0.25VA/phase(Rated current 1A) | |||||
Measurement range | 8A:0~6A, 1A:0~1.2A | |||||
Input/Output | Switch input | 4-way passive main line contact DI input, internal supply DC24V power source | ||||
Relay output | 4-way DO output,Contact capacity 250VAC/5A,30VDC/5A | |||||
Analog output | Output range 4~20mA,overload allows 1.2times | |||||
Temperature output | Measure range 0℃~100℃ | |||||
Power quality monitoring | Harmonic measurement | Voltage/current2~51th harmonic distortion rate, total harmonic distortion rate | ||||
Harmonic distribution rate | Phase voltage, line voltage | |||||
Umbalance rate | Voltage, current | |||||
Measurement accuracy | Voltage | ±0.2%(0.01V) | ||||
Current | ±0.2%(0.01A) | |||||
Active power | ±0.5%(0.1W) | |||||
Reactive power | ±2.0%(0.1var) | |||||
Active energy | ±0.5(0.1kWh) | |||||
Reactive energy | ±2.0%(0.1kvarh) | |||||
Power factor | ±0.5%(0.001) | |||||
Frequency | ±0.02Hz(0.01Hz) | |||||
Communication | Communication interface | RS485 photoelectric isolation interface | ||||
Communication protocol | Modbus-RTU, 1200~19200bps | |||||
Electric insulation | Power frequency withstand voltage | AC2/kV/min~1mA input-output-power (GB/T13829) | ||||
Insulation resistance | >50MΩ | |||||
Impact voltage | 5kV (peak),1.2/50μs | |||||
Working environment | Working temperature | -25℃ ~ +70℃ | ||||
Related humdity | 5%~95% no condensation | |||||
Storage environment | -30℃ ~ +75℃ |