Three phase electronic panel meters watt-hour Power meter KPM73
Negotiable
Min.Order:1
KPM73 Series Multifuation meter with accurate power parameter measurement, bidirectation four quadrant energy measurement, statistics, electrical instruments, record and other function. Using advanced ARM processor and digital signal processing technology, Collect comprehensive three-phase electrical parameters measurement/display, energy accumulation, power quality analysis, multi-rate statistics, digtial input/output and communications network in ones.It has fine manufacture process, good electrical insulation and electromagnetic compatibility, large screen LCD liquid crystal display and other advantages.
Selection Critical:
Working power supply |
Rated voltage |
AC85~265V/DC80~300V |
Rated power consumption |
<3VA |
|
Input Voltage |
Rated voltage |
57.7/100V, 220V/380V, 380/660V(Customized) |
Threshold value |
5V |
|
Overload capacity |
1.2 times rated voltage, continuous operation, 2 times rated voltage, allow 10S |
|
Power consumption |
<0.75VA/phase (Rated 5A) |
|
Measurement range |
Phase voltage (LN):50~260VAC Line voltage(LL):90~450VAC |
|
Input current |
Rated current |
Default 5A,Input range 1-6A;Optional 1A |
Threshold value |
5A Configuration,5mA; 1A Configuration |
|
Overload capacity |
1.2 times rated current allowed, continuous work; 20 times the rated current allowed 1 second |
|
Power consumption |
<0.75VA/phase(Rated current 5A);<0.25VA/phase(Rated current 1A) |
|
Measurement range |
8A:0~6A, 1A:0~1.2A |
|
Input/Output |
Switch input |
4-way passive main line contact DI input, internal supply DC24V power source |
Relay output |
4-way DO output,Contact capacity 250VAC/5A,30VDC/5A |
|
Analog output |
Output range 4~20mA,overload allows 1.2times |
|
Temperature output |
Measure range 0℃~100℃ |
|
Power quality monitoring |
Harmonic measurement |
Voltage/current2~51th harmonic distortion rate, total harmonic distortion rate |
Harmonic distribution rate |
Phase voltage, line voltage |
|
Umbalance rate |
Voltage, current |
|
Measurement accuracy |
Voltage |
±0.2%(0.01V) |
Current |
±0.2%(0.01A) |
|
Active power |
±0.5%(0.1W) |
|
Reactive power |
±2.0%(0.1var) |
|
Active energy |
±0.5(0.1kWh) |
|
Reactive energy |
±2.0%(0.1kvarh) |
|
Power factor |
±0.5%(0.001) |
|
Frequency |
±0.02Hz(0.01Hz) |
|
Communication |
Communication interface |
RS485 photoelectric isolation interface |
Communication protocol |
Modbus-RTU, 1200~19200bps |
|
Electric insulation |
Power frequency withstand voltage |
AC2/kV/min~1mA input-output-power (GB/T13829) |
Insulation resistance |
>50MΩ |
|
Impact voltage |
5kV (peak),1.2/50μs |
KPM10 Three phase multifunction power meter KPM200 Communication manager/gateway
KPM 60 low voltage motor protection controller KPM33 Three phase DIN power meter
|
|
|
|
1.Experienced manufacturer more than 10 years.
2.Highly experienced production team in Compere factory work-shop.
3.QC System:Quality controlled on all production lines,and QC inspectors work independently from the production line.
4.Good quality production with quick delivery.
5.Accepted OEM/ODM.
6.Accepted small MOQ.
7.Trade Assurance on Alibaba.
8.Factory certification:CE,RoHS and ISO9001.