72*72mm smart panel digital multifunctional Power Meter
Negotiable
Min.Order:1
Power Quality Analyser AC multifunction Smart Power Quality Analyzer RS485 Modbus Power Meter
New power quality analyzer great price three phase digital power meter power factor meter
KPM75 Analyzer Power Energy Meter Wattage Voltage Current Frequency Power LCD
KPM75 High Quality Indoor Wall Mount Enclosure Multi-rate Energy Meter Power Analyzer
KPM75 Portable Power Quality Analyzer RS485 Power Meter Energy Analyser Power Monitoring
3 phase digital panel smart power meter with size 72x72mm and LCD display modbus RS485 port
Model selection of Modbus RS485 ethernet digital electric smart power meter
KPM10 Modbus RS485 ethernet 3 phase digital electric smart power meter | ||
Working Power Source | Operating Voltage | AC85~265V/DC80~300V |
Rated Power | <3VA | |
Input Voltage | Rated Voltage | 57.7/100V,220/380V, |
380/660A (needs customization) | ||
Sill Value | 5V | |
Overload Capacity | 1.2 times rated voltage allowed,continuous work; | |
2 times the rated voltage allowed 1 second | ||
Power Consumption | <0.5VA/phase(rated) | |
Measurement Range | 5~260VAC, | |
Frequency Range | 45~65Hz | |
Input Current | Rated Current | Default 5A,Input range 1-6A;Optional 1A,Input range 1-1.2A |
Sill Value | 5A Configuration,5mA;1A Configuration,0.8mA | |
Overload Capacity | 1.2 times rated current allowed,continuous work; | |
20 times the rated current allowed 1 second | ||
Power Consumption | <0.75VA/phase(Rated current 5A);<0.25VA/phase(Rated current 1A) | |
Frequency Range | 45~65Hz | |
Input/Output | Switch Value Input | 2-way passive main line contact DI input, |
internal supply DC24V power source | ||
Relay Output | 2-way DO output, | |
Contact capacity 250VAC/5A,30VDC/5A | ||
Power Quality Monitor | Harmonic Measurement | Voltage/current2~21th harmonic distortion rate, |
total harmonic distortion rate. | ||
Harmonic Distortion Rate | Phase voltage,line voltage | |
Imbalance Rate | Voltage. current | |
Measurement Accuracy | Voltage | ±0.2%(0.01V) |
Current | ±0.2%(0.01A) | |
Active Power | ±0.5%(0.1W) | |
Reactive Power | ±2.0%(0.1kvar) | |
Active Energy | ±0.5%(0.1kWh) | |
Reactive Energy | ±2.0%(0.1kvarh) | |
Power Factor | ±0.5%(0.001) | |
Frequency | ±0.02Hz(0.01Hz) | |
Temperature | ±1℃(1℃) | |
Communication | Communication Interface | RS485,Photoelectric isolation interface |
Communication Protocol | Modbus-RTU,1200~38400bps | |
Electrical Insulation | Power Frequency | AC2kV/min~1mA |
Withstand Voltage | Input-output-power source (GB/T 13729) | |
Insulation Resistance | >50MΩ (GB/T 13729) | |
Impact Voltage | 5kV(Peak)1.2/50us (GB/T 13729) | |
Working Environment | Operating Temperature | -25℃ ~ +70℃ |
Relative Humidity | 5%~95% No condensation | |
Storage Temperature | -30℃ ~ +75℃ | |
Altitude | No more than 4000m |
T@Energy Smart Energy Management System | KPM204 Serial to ethernet gateway | KPM202 Modbus to ethernet gateway |
KPM53 Smart power meter | KPM10 Smart power meter | KPM37 DIN rail smart energy meter |