TP-6100 Insulating oil dielectric loss tangent analysis instrument,Dissipation Factor and Tan Delta Oil analyzer
Negotiable
Min.Order:1
IEC 156 Transformer Oil Tester Dielectric,80KV BDV Vacuum Oil Tester,Transformer Oil Testing Kit
Transformer Oil Loss Factor, Power Factor Measure,ASTM Oil Dielectric Loss Tester
Power Transformer Capacitance Dissipation Testing Kits,Tan Delta Analyzer
Transformer Tan Delta,Capacitance Measuring,Dissipation Factor Tester
VLF low Frequency high voltage tester,power cable and generator insulation test machine
Main features:
> Oil cup used a three-electrode structure in line with GB / T5654-2007, the inter-electrode spacing of 2mm, can eliminate the impacts of stray capacitance and leakage impact on the dielectric loss test results. It has a drain solenoid switch, you can drain all the sample oil in the oil cup without removing the oil cup and rinse the oil cup with sample oil.
> The instrument uses mid-frequency induction heating, PID temperature control algorithm. This heating method has some advantages, eg, oil cup and heating body non-contact, heating evenly and quickly, also easy to control, thus the temperature strictly controlled within the preset temperature range of error.
> Internal standard capacitors for SF6 inflatable three-pole impact of capacitors, the capacitor dielectric loss and electrical capacity are not affected by ambient temperature, humidity, etc., to ensure that the instrument is still consistent accuracy after prolonged use.
>AC Test Power Supply with AC-DC-AC conversion, effectively prevent affecting of the dielectric loss test accuracy for the mains voltage and frequency fluctuations, even the generator generate electricity, the instrument can also run properly.
> Complete protection. When there is over-voltage, over-current, short-circuit for high-voltage, the instrument can be quickly cut off the voltage and warning. When the temperature sensor fails or is not connected, the instrument will give a warning message.
there is a limiting temperature relay amounted in the mid-frequency induction heating furnace, when the temperature exceeds 120 degrees, the relay release, then the heating stop.
> easy to set the parameters. Temperature setting range 0 ~ 125 ℃, the AC voltage setting range 500 ~ 2200V, the DC voltage setting range 0 ~ 500V.
> Large-screen LCD display with backlight, clear display. Friendly interface, simply follow the English menu prompt, enter the command, the instrument can be automatically tested. And automatically store and print test results.
> With real-time clock, test date and time can be saved with the test results, display and print.
> Empty electrode cup calibration. measuring capacitance and dielectric loss factor of empty electrode cup to determine the status of empty electrode cleaning and assembly of the cup. Calibration data is automatically saved, conducive to calculate the relative permittivity and DC resistivity precisely.
The main technical indicators:
> Power supply voltage: AC 220V ± 10%
> Power Frequency: 50Hz / 60Hz ± 1%
> Measuring range: capacity: 5pF ~ 200pF
Relative permittivity: 1.000 to 30.000
Dielectric loss factor: 0.00001 to 100
> DC Resistivity: 2.5 MΩm ~ 20 TΩm
> measurement Accuracy: Capacitance: ± (1% of reading + 0.5pF)
Relative permittivity: ± 1% of reading
Dielectric loss factor: ± (1% reading +0.0001)
DC resistivity: ± 10% of reading
> Resolution: capacity: 0.01pF
Relative permittivity: 0.001
Dielectric loss factor: 0.00001
> Temperature range: 0 ~ 125 ℃
> Temperature measurement error: ± 0.5 ℃
> AC test voltage: 500 ~ 2200V continuously adjustable frequency 50Hz
> DC test voltage: 0 ~ 500V continuously adjustable
> Applicable Temperature: 0 ℃ ~ 40 ℃
> Applicable Humidity: <75% RH
> Power: 100W
Series ZY Single-stage vacuum transformer oil purifier
Series ZYD Double high vacuum transformer oil purifier
Series ZYD-I Double vacuum transformer oil purification and regeneration machine
Series ZYB Multi-function insulating oil regeneration machine
Series TY Turbine oil purification apparatus
Series TYA Lubricating oil/ hydraulic oil purification unit
Series TYB Portable light fuel oil purification machine
Series TYD Vacuum lube oil/hydraulic oil dehydrator
Series TYF Phosphate ester fire-resistance oil purifier
Series PL Plate pressure oil purifier
Series JL Portable oil filtration machine
Series COP Cooking oil purification machine
Series CYS Centrifugal oil purification machine
Series BAM Press filtration system
Series HFD/VFD filter press machine
Series ZKCC Vacuum pumping system
Series EOS Waste Oil Distillation Plant
1.Transformer oil breakdown voltage tester ( BDV test kit) IIJ-II / DYT Series
2. Acidity tester ACD-3000I
3. Karl Fischer water content tester TP-6A / TP-2100
4. Online moisture content tester(TPEE)
5. Fully automatic interface/surface tension analyzer IT-800
6. Gas-chromatography transformer oil gas analyzer DGA2013-1
7. Cloud point and pour point tester PT-2000
8. Kinematic viscosity tester VST-2000 / TPV-8
9. Flash point tester (open cup) TPO-3000
10. Flash point tester (close cup) TPC-3000
11. Transformer comprehensive tester (CT/PT tester) TPVA-404 / TPVA-402
12. Transformer turn ratio tester HYG-II / TPOM-901
13. Total base number analyzer(TBN tester) TBN-2030
You can contact me online or send offline message. Also you can directly contact me at the following address: