Current Transformer Analyzer/Transformer Turn Ratio Measuring Instrument
Negotiable
Min.Order:1
Portable argon gas analyzer with imported electrochemical sensor and micro-controller technique
ASTM D1533 Automatic Karl Fischer Titration Moisture Analyzer
ASTM D1533 Water in Insulating Liquids analyzer by Coulometric Karl Fischer Titration
Microcomputer Relay Test kit RPT-PC for the safety of electric power system
Current Transformer Analyzer/Transformer Turn Ratio Measuring Instrument
(TPVA-404 Model)
Application
1. Tests for current transformer:
1)Excitation curve and parameters test
2)Turns ratio test
3)Ratio and phase error test
4)Polarity mark check
5)Coil resistance measurement
6)Secondary loop burden measurement
7)Error line curve test for protection CT
8)Transient CT parameters test
9)CT nameplate guess
10)Saturation hysteresis loop curve measurement
2. Tests for voltage transformer:
1)Turns ratio test
2)Polarity test
3) Secondary burden test
4) Coil resistance test
3. Applications for CTPT analyzer:
1)CT nameplate check
2)CT parameters check in work burden
3)CT transient parameters analysis
4)CT ratio and phase error calibration
5)PT routine test
1 Test standards: IEC60044-1, IEC60044-6, GB1208, GB16847, C57.13
2 Power supply: AC220V±10%,50Hz/60Hz±10%
3 Power output: 0.1~125V (AC)
4 Current output: 0.001~5A(RMS)
5 Power output: 300VA
6 Maximum knee voltage measurement; 45kv
7 Current measurement:
Range:0~10A (automatically change range in 0.1/0.4/2/10A)
Error <±0.1%+0.01%FS
8 Voltage measurement:
Range:0~200 V (automatically change range in 1V/10V/70V/200V)
Error < ±0.1%+0.01%FS
9 Turns ratio measurement:
Range :1~35000,
1~2000 error<0.05%
2000~5000 error>0.1%
5000~35000 error<0.2%
10 Phase measurement: error:±2min,resolution:0.01min
11 Coil resistance measurement:
Range:0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm)
Error< 0.2%RDG+0.02%FS
Maximum resolution:0.1mΩ
12 Temperature measurement:-50~100 Celsius degree, error<3 Celsius degree
13 CT Secondary burden:
Range 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)
Error <0.2%RDG+0.02%FS
Maximum resolution 0.001ohm
14 PT Secondary burden:
Range 0~80kohm (automatically change range in 800ohm/8kohm/80kohm)
Error <0.2%RDG+0.02%FS
Maximum resolution: 0.1ohm
15 PT ratio measurement:
Range :1~35000,
1~5000 error<0.2%
5000~35000 error<0.5%
16 Saved data groups:>1000groups
17 Work condition: Temperature:-10℃~50℃, moist:≤90%
18 Size: 485mm×356mm×183mm
19 Weight: <15Kg
Transformer related testers
Insulating Oil Testers
1. Fully Automatic Insulating Oil Dielectric Strength Tester IIJ-II
2. Fully Automatic Insulating Oil Dielectric Strength Tester DYT
3. Fully Automatic Insulating Oil Dielectric Strength Tester DYT-2
4. Three Cups Insulating Oil Dielectric Strength Tester IIJ-III
5. Six Cups Insulating Oil Dielectric Strength Tester IJJ-VI
6. Insulating Oil Dielectric Strength Tester IIJ-603
7. Insulating Oil Tan Delta ( Dielectric Loss) Tester DLT0812
8. Insulating Oil Dielectric Loss And Resistivity Tester TP-6100A
9. Fully Automatic Water-Soluble Acid Value Tester PH-C
10. Fully Automatic Surface/Interface Tension Tester IT-800
11. Fully Automatic Oil Acidity Tester (6 cups) ACD-3000I
12. Insulating Oil Gassing Property Tester DPT-20
13. Insulating Oil Oxidation Stability Tester TP622
14. Multifunctional Shaker SD-01
15. Insulating Oil Water Content Tester TP-2100
16. Online Insulating Oil Water Content Tester TPEE
17. Transformer Oil Dissolved Gas Chromatograph DGA
Transformer Testers
1. Transformer Load And No-load Tester TOFT
2. Transformer Winding Deformation Tester TPWD-902
3. Transformer Capacity Tester TPTC
4. Transformer On-Load Voltage Regulation Switch Tester OLTC-2000
5. Transformer Turn Ratio Meter TPOM-901
6. Capacitance and Dissipation Factor Tester /Tan Delta Tester CDEF
7. DC Resistance Tester TPZC
Transformer Characteristics Testers
1. CT/PT Transformer Characteristics Comprehensive Tester TPVA-402
2. CT/PT Transformer Tester TPVA-404
3. Strong Current Generator SLQ
Trustable technical and after sale service
1. Long-term warranty of 2 years.
2. Provide best necessary spare parts at low price (some for free).
3. Provide timely reply and technical support within 24 hours.
4. OEM is available for TOP Products.
5. Protect your sales area, ideas of design and all your private information.
Reliable packing & Prompt delivery
Key words: current transformer analyzer, automatic transformer tester, current transformer tester, transformer turns ratio tester, 3 phase transformer turn ratio tester, CT ratio tester, transformer turn ratio, machinery for transformer testing, transformer tester, ttr transformer turns ratio tester, current transformer analyzer, ct analyzer, test transformer, transformer testing, ttr tester, transformer ttr tester, transformer ct pt testing equipment, resistance tester, phase error test, ctpt current transformer testing equipment, ct pt tester, ct pt transformer tester, ct/pt analyzer, ct pt testing equipment, transformer turns ratio test set, current transformer test set, transformer test set, testing kit for current transformers, transformer ratio testing kit, transformer ct pt analyzer, comprehensive transformer tester,transformer turn ratio measuring instrument