ASTM D4294 X-Ray Method Sulfur Content in oil analysis kit (TPS-130)

ASTM D4294 X-Ray Method Sulfur Content in oil analysis kit (TPS-130)

Negotiable

Min.Order:1

Supply Ability:
1000 per Month
Payment Terms:
T/T Credit Card

Chongqing Top Oil Purifier Co., Ltd

Business Type: Association
Main Products: , , ,

Product Details

ASTM D4294 X-Ray Method Sulfur Content in oil analysis kit (TPS-130)

A: Summary and purpose
1. Summary
TPS-130X-ray Fluorescence Sulfur Analyzer is specially designed to determine sulfur content in the petroleum products. Adopts energy-dispersive principle, and with electrical, mechanical and microprocessor integration design, so it is rapid and accurate.
 TPS-130X-ray Fluorescence Sulfur Analyzer provides a measure to determine sulfur content during petroleum or petrochemical production process, Can meet the requirements of national standard GB/T 17040,SH/T0742 and GB/T11140 on repeatability and reproducibility, and it can also meet requirements of ASTM D4294-03 on these indexes.
 
2. Purpose
(1) It can be used to determine mass% of total sulfur in the crude petroleum, petroleum, heavy oil, diesel oil, gasoline, and naphtha.
(2) It can be used to determine total sulfur content in the products of coal chemical industry, such as primary benzene.
(3) It can be used to determine total sulfur or sulfide in other liquid or solid powder samples.
 

B:Technical specifications and parameters.
1. Instrument characteristics
(1) With electrical, mechanical and microprocessor integration design, so it is compact and beautiful;
(2) It can determine various products and in a wide measurement range. It is rapid for analysis and it only need little standard sample.
(3) Adopts fluorescence intensity ratio analysis methods, it can make correction to temperature and pressure automatically and it can also make correction to ratio of carbon and hydrogen (C/H).
(4) Large LCD for display; Man-machine conversation system; Sound alarm for operation mistake;
(5) It has self-diagnostic function, so it can determine its working state and electric parameters by making counting measurement and energy spectrum measurement using reference samples.
(6) Equipped with a RS232 serial port, it can connect with any computer or web system.
(7) It takes disposable sample cell with Mylar film, so it can avoid cross contamination. Sample cell is made by a multifunctional pressure shaping device, so it is rapid and convenient. There is a hole on the sample cell cover and you can record sample serial number, S% (m/m), and date on the sample cell cover.
(8) The sample holder is installed on a slide rail, so it can move out and move in automatically. It can move out from inside of the instrument for sample location and anti-leakage parts replacement. It is convenient and it can avoid any contamination to detection system.
(9) It can save large quantity of test data. You can browse test data and calibration curves at any time.
(10) It uses a thermal printer, so it is easy to replace printing paper.
(11) Tightly protection measures to avoid oil leakage. The sample cell is placed on the leakage protection device. The sample cell can enter into the detection system together with the leakage protection device only during sample analysis procedures. If the instrument is not at sample analysis state, the leakage protection device will move out, so this can avoid any contamination to the detection system.
(12) Its safe X-ray protection measures can keep people from injury of X-ray radiation.
 

C: Main technical specification and parameters
(1) Measurement range: 7 ppm to 5%
(2) Repeatability (r): <0.02894 (X+0.1691)
(3) Reproducibility (R): <0.1215(X+0.5555)
(4) Detection limit: 7 ppm
(5) Oil sample quantity: 2.5 ml (it is equal to sample depth of 4.5 mm)
(6) Measurement time: it can preset 60, 120, 240, 300, and 600 s at random
(7) It can make measurement automatically for single sample. Repeat times: can set 2, 3, 5, 10, and 50 at random; it will show average value and standard deviation at end of measurement.
(8) Calibration curve numbers: it can save 9 calibration curves. 5 pieces of them are unary     linear equation and 4 pieces of them are unary quadratic equation.
(9) Working condition:
a. Ambient temperature: 5~40°C
b. Relative humidity: ≤85% (30 °C)
(10) Power supply: AC 220V±20V, 50 Hz; Rated power: 30 W
(11) Size and weight: 468mm×368mm×136mm; 13 kg


Oil tester, analysis instrument, testing equipment, testing machine, testing kit, testing device, oil testing kit,  testing unit, test equipment, test machine, test device, lab analyzer, lab instruments, lab test equipment, lab test kits, lab testing, laboratory equipment, measurement meter, measurement test equipment, measuring & gauging tools, measuring device, measuring equipment, measuring instruments, measuring tester, moisture content sensor, new measuring instruments, oil analyser, oil analysis, oil analysis equipment, oil analyzer, oil lab equipment, oil test kit, oil measuring instrument, tools and equipment, testing laboratory, testing instrument, tester unit, tester set, oil testing machine, tester device, test kit, test equipment, test and measurement, oil testing unit, oil testing machine, oil testing device, oil tester machine, oil test equipment, oil quality analyzer, oil moisture sensor, oil moisture meter, analysis equipment, oil test set<o:p>

Our oil filtration machine:
Series ZY Single-Stage Vacuum Transformer Oil Purifier
Series ZYD Double High Vacuum Transformer Oil Purifier
Series ZYB Multiply-Function insulating oil treatment machine
Series TY Turbine Oil Purification Apparatus
Series TYA Lubricating oil/ hydraulic oil purification unit
Series TYB Portable light Fuel oil purification machine
Series TYD Vacuum dehydrator
Series TYF Phosphate ester fire-resistance oil purifier
Series PL Plate pressure oil purifier
Series TYD Vacuum dehydrator
Series EFD Explosion protection filtration machine
Series BAM Press filtration system
Series ZKCC Vacuum pumping device
Series COP Cooking oil purification machine
Series CYS Centrifugal oil purification machine
Series JL Portable oil filtering and oiling machine
Series EOR series waste engine oil recycling system


Test equipment
1.Transformer oil Breakdown voltage Tester ( BDV test kit) series IIJ-II
2.Acidity tester model ACD-3000I
3.Karl Fischer Water content Tester Model TP-6A / model TP-2100
4.Fully automatic Interfacial Tension Analyzer model IT-800
5.Gas-Chromatography transformer oil gas analyzer model DGA2013-1
6.Kinematic Viscosity tester model VST-8 /model VST-2000
7.Flash point tester (open cup) model TPO-3000
8.Flash point tester (close cup) model TPC-3000
9.TAN-DELTA TESTER,10kV Capacitance and Dissipation Factor Test Set model CDEF
10.CT/PT tester model TPVA-404
11.Transformer turn ratio tester model HYG-II
12.Relaying Protection Tester model TPJB-III

Contact Supplier

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Other Measuring & Analysing Instruments
Categories
Hi~