GC2010 Transformer Oil Gas Chromatography Analysis Device for Residual Solvent (ethyl) in cbd Oil,Petroleum Products GC Tester
Negotiable
Min.Order:1
Model HVS-I High Voltage Circuit Breaker Operating Mechanism Tester,HV Switch Analyzer
Series TP-2100M Silicon Steel Sheet Iron Core Loss Tester,Iron Loss Analyzer,Iron Hardness Meter
Series TP-2100M High Precision Silicon Steel Sheet Iron Core Loss Tester,Iron Loss Testing Equipment
Portable high accuracy argon gas analyzer/ easy operation gas tester with quick response
GC2010 Transformer Oil Gas Chromatography Analysis Device for Residual Solvent (ethyl) in cbd Oil,Petroleum Products GC Tester
Product Application
1. Applicable boiling range: petroleum products or distillates of 55~550℃ boiling range distribution such as fuel, kerosene, diesel, lubricants, wax oil etc. On this chromatographic condition tested sample components
can all show the peaks. It adopts area normalization method to fix quantity. It complies to SH/T 0558-2002 and ASTM D2887standard.
2. Applicable boiling range: crude oil of initial boiling point~538℃ boiling range distribution. Get distribution
proportion of fuel, diesel, kerosene, heavy oil. Since the heavy components above 538℃ can not show peak,
it adopts incremental internal standard method and complies to ASTM D5307 standard.
3. Applicable boiling range: petroleum products or distillates of 55~680℃ boiling range distribution. On this chromatographic condition tested sample components can all show the peaks. It adopts area normalization
method to fix quantity.
Product Features
1. Adopts American Agilent 5890 gas chromatographic core tech; green backlight LCD screen; easy operation.
2. Temperature control upper limit max use temperature of 450℃for every instrument heating area.
3. Dual channel single column compensation; base line drift when program heat to operate FID test;
ensure base line straight and chromatography peak shape perfect.
4. Adopts imported heat-resistant large aperture metal capillary column to separate; mas analysis
use temperature of 450℃.
5. Can display and print C5-C44 n-alkanes calibration sample boiling point-time calibration curve.
6. Can provide oil sample boiling point-yield boiling range curve.
7. Can provide detailed boiling range report regarding 1% yield interval; also can provide it regarding 5℃, 10℃, 20℃, 30℃, 50℃, 100℃ boiling range.
8. Can be equipped with AS-2902 highly efficient auto liquid sample injector; auto injection analysis with unattended operation achieved; analysis efficiency improved and labor intensity reduced.
Technical Parameter
Temperature control index
Oven/ Sample injector/ detector: above room temperature 5℃~450℃; precision ±0.1℃
Column oven parameters
Temperature control range: above room temperature 5℃~450℃; precision ±0.1℃
Program heating stages: 3 stages
Program heating speed: 0.1℃~50℃, increment 0.1℃
Program heating keeping time: 0~655 min (increment 1 min)
Big oven volume; back pullout design; program quick cooking after heating. Cooling speed: only 7min from 350℃ down to 60℃.
Injection method
Capillary split/unsplit stream injection: flash distillation injection
Packed column head injection: flash distillation injection
Can be equipped with unattended operation auto injector.
Hydrogen flame ionization detector (FID)
Easy disassembly and installation; convenient for cleaning and displacing nozzle; easy operation; can input signal to logarithmic amplification to reduce interference; high sensitivity, good linearity and wide range.
Limit of detection (LOD): Mt ≤ 5×10-12g/s (n-Hexadecath)
Baseline noise: ≤ 6×10-12A/H
Linearity range: ≥ 105
Stability time: < 0.5h
Chromatographic working station
24 bits high precision digital-to-analogue conversion (DAC)
Dual channel synchronous or asynchronous work
USB port; can be connected to external power supply; with serial port
Input voltage range: -1V~1V
Integral sensitivity: 0.05uV•s
Min solution: 1uV
Dynamic range (DR): 107
Sample frequency: Max 60 times/sec; adjustable program variables
Detailed Images
N-alkanes analysis spectrogram
C5-C44 n-alkanes calibration sample boiling point-time calibration curve
Diesel simulated distillation spectrogram
Keywords for GC2010 Series
gas analysis instruments, gas analysis device, transformer oil dissolved gas analyzer, dissolved gas analyzer, dissolved gas analysis, gas analyzer, gas chromatography, gas chromatograph, gas chromatography system, portable gas analyzer, gas chromatography instrument, transformer oil gas chromatography, transformer oil gas analysis, Gas chromatograph, gas detector, transformer oil gas analyzer, gas chromatography machine, dga, portable transformer oil gas dissolved gas analyzer, gas chromatography for transformer oil gas analyze,gc gas chromatography
For more information,Please Contact Us As Follows: