Acrel AC current sensor input:AC 0-200A output:DC 0-5V/0-10V CTs true RMS accuracy class 0.5 0.2 current transducer BA20-AI/V
Acrel AC current sensor input:AC 0-200A output:DC 0-5V/0-10V CTs true RMS accuracy class 0.5 0.2 current transducer BA20-AI/V
Acrel AC current sensor input:AC 0-200A output:DC 0-5V/0-10V CTs true RMS accuracy class 0.5 0.2 current transducer BA20-AI/V
Acrel AC current sensor input:AC 0-200A output:DC 0-5V/0-10V CTs true RMS accuracy class 0.5 0.2 current transducer BA20-AI/V
Acrel AC current sensor input:AC 0-200A output:DC 0-5V/0-10V CTs true RMS accuracy class 0.5 0.2 current transducer BA20-AI/V

Acrel AC current sensor input:AC 0-200A output:DC 0-5V/0-10V CTs true RMS accuracy class 0.5 0.2 current transducer BA20-AI/V

Negotiable

Min.Order:1

Supply Ability:
1000 per Month
Payment Terms:
T/T Credit Card

Acrel Electric Co., Ltd

Business license
Business Type: Manufacturer
Shanghai China
Main Products: Hall Sensor ,Split Core Current Transformer ,AC Energy Meter ,DC Energy Meter ,IoT Wireless Power Meter ,PV/Solar Inverter Energy Meter ,Data Center Power Meter ,Wireless Temperature Monitoring System and Sensors ,Medical IT Products ,City Utility Tunnel Moter Protector ,Electrical Insulation Safety Products ,Energy Quality Improvement

Product Details

Solutions & Applications
Application Scenario
Petrochemical
Siderurgy
Rail Transportation
Products Description




BA20-AI/V ----------BA Series AC Current Sensor

BA20-AI/V, AC current input, DC voltage output
BA series CTs can measure the AC from power grid in real time by using electromagnetic induction principle (Lenz's Law). Meanwhile,with constant current and linear temperature compensation technique, can BA current sensors
transfer AC input into standard DC signal output isolatedly. Also,since the products are powered by safe DC 24V or DC 12V power supply, BA CTs have features of such as high overload sustainability, safe using protection, low power consumption and etc. Thus they can be widely used in the industrial field like industry automation
Also, as the prove for quality, BA series AC current sensor is strictly compliant of the standard of CE (EN 60688:2013, EN 61010:2010+A1:2019, EN 61326-1:2013);TUV(EN 62321-1:2013, EN 62321-2:2014 and etc). Certificates are shown below

Explanation of Model Name
Function & Parameter
General Specification
Item
Description
Power
Supply
Voltage
DC 24V or DC 12V
Consumption
≤ 1W
Insulation Resitance
>100 MΩ
Withstand Strength
Between input/output, power supply 2.0 kV/1min, 50Hz
Temperature Coefficient
≤200 PPM/℃,under -10℃~+55℃

Environment
Temperature
Working: -10℃~+55℃, Storage: -25℃~+70℃。
Humidity
≤95% RH, No condensation, without corrosive gas
Altitude
TS35 guide rail or fiexed on cabinet with screws
Technical Parameters
Paramters
Value&Description
Accuracy Class
class 0.5, class 0.2



Input
Nominal Value
AC 0~200 A
Overload
continuous overload 1.2×Ib (1.2 times of nominal value); 
instant overload 10×Ib/1s (10 times of nominal value for 1 second)
Absorbed Power
≤1 VA
Frequency response
25Hz~800Hz (average);
25Hz~5000 Hz(true RMS), specialized for power frequency scenario
Output
Nominal Value
DC 0~5V, DC 0~10V etc.
Load Resistance
≤500 Ω with current output; ≤1000 Ω with voltage output
Response Time
≤ 350 ms (average); ≤100 ms (true RMS)
Dimension & Installation
Dimension Overview

Wiring Illustration
Wiring instruction for BA with voltage output
1--E: stand for power supply anode (+)
2--G: stand for power ground
3--Output ground(can share groud with power supply, suitable for long rage transmission)
4--VDC: stand for DC voltage output anode(+)

Installation Instruction
① 35mm DIN rail installation
② Fixed by screw
Company Profile
Acrel Co., Ltd. [Stock Code : 300286. SZ] is a high-tech enterprise concentrating on research, production, sales and services. It mainly provides systemic solutions of energy efficiency management and electrical safety for users. ‘Acrel’ is equipped with the complete production lines from cloud platform software to sensors. Until now, it has more than 8000 sets systemic solutions used in China to help users to realize energy visual management ,supply energy data services and improve electrical efficiency and safety. ‘Acrel’ has maintained steady growth since its listing in 2012. The company will adhere to the concept of ‘innovation,high-efficiency,unity and honesty’ and it provides more high-quality solutions,products and service for power system users and micro-grid.
Payment & Delivery
1.Payment: T/T 100% in advance, credit card, western union, in cash and etc. T/T 30% as deposit and the balance before shipment or against copy of B/L is acceptable with enough MOQ.

2.Delivery Arriving Time: in 3-7 working days after payment received.

3.Ways of Delivery: By sea, air, train or international courier like Fedex, TNT, DHL and UPS.
FAQ
Contact

Contact Supplier

Ms. Shelly Zhang sales manager Chat Now
Telephone
86-21-18702111813
Mobile
86-18702111813
Fax
86-21-69155906
Address
No.253 Yulv Road, Jiading District, Shanghai
Whatsapp
86-18702111813

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Power Accessories
Categories
Hi~