DC Leakage current sensor BA50L-AI/V Input 0-1A Leakage current output dc0-5V
Negotiable
Min.Order:1
General
BA series conduct the real-time measurement on the alternating current in the power grid according to the electromagnetic induction theory. They utilize the precise constant current technology and the linear temperature compensation technology to isolate and convert the measured current into the DC signal. They adopt the 24V or 12V power supply. They feature the large overload capacity,high accuracy,isolation and safety and low power consumption.Application cover the industrial automation sector.
BA series residual current sensors are designed to monitor the electric leakage and detect the insulation of electrical circuit or electrical equipment in order to avoid accidents arising from reduction of insulation performance of electrical circuit or electrical equipment.The product complies with GB/T13850-1998 and GB1208-2006.
Explanation for type
Note: BA50L-AI/I(V): alternating residual current sensor
Technical data
Technical parameters | Index | |
Input signal | BA50L-AI/I measuring range AC0~(0.1-1)A | |
Output | Nominal value | DC4-20mA |
Overload protection | Max.output≤135% of full scale | |
Load resistance | when current output:(supply voltage-4/0.02)Ω | |
Ripple component | AC component of the output signal≤1% of full scale | |
Power supply | DC24V allowed range 18~30V DC12V allowed range 10~15V | |
Power consumption | ≤1W | |
Dielectric strength | Power frequency withstans voltage 2000VAC between input/output and power supply | |
Pricision degree | 0.5 | |
Temperature drift coefficient | ≤200ppm | |
Response time | Average≤350mS | |
Installation method | TS35mm guide installation,or screw in cabinet | |
Ambient conditions | Temperature | Operating temperature:-25℃~+70℃ Storage temperature:-40℃~+85℃ |
Humidity | ≤90%RH,no dew,no aggressive gas | |
Altitude | ≤2500m |
Shape and hole size
The shape and hole size of BA50L residual current transformer.
Type | Outline size(mm) | |||||
W | H | φ | M | N | L | |
BA50L-AI/I | 35 | 84 | 50 | 125 | 135 | 24 |
Example of Wiring
As shown in the figure,the input is lac.The output of current output sensor is the current source with common GND while the output of voltage output sensor is the voltage source with common GND.In this example,RL is the user load.If the output is current,the load is up to 400Ω(with 12V power supply) or 800Ω(with 24V power supply). If the output is voltage,the load is 1kΩ or above.
Acrel Co., Ltd. [Stock Code: 300286.SZ] is one of the few leading companies in China who provides various systematic solutions of power monitoring, power control, energy management and electrical safety for smart grid users.
Since June 2003, we has always been focused on the research, production and sales of intelligent electric meters. We concentrates on providing products and services to help customers improve electricity efficiency and safety. So far we had the following comprehensive solutions for different applications: 35(10)/0.4kV substation automation system, building mounted photovoltaic (BMPV) system, power quality management system, energy management system, electrical fire monitoring system, IT distribution system for medical locations, precise distribution management system, power supply monitoring system for fire protection equipment, fire emergency lighting and evacuate indicating system, fire resistant doorsets monitoring system, smart lighting control system, Lithium battery management system and electric vehicle charging system.
Certificate
Packing
Shipping