X-ray Diffraction Analyzers Mini XRD
USD $50,000 - $70,000 /Set
Min.Order:1 Set
Wuxi Jinyibo Instrument Technology Co., Ltd.
DJ-10 Mini Desktop X-ray Diffractometer
The Advanced Desktop X-ray Diffractometer
Multi-function and miniaturization
Peak accuracy 0.001°
Quantitative analysis
Crystal structure analysis
Commercial process and quality control
Especially for catalyst, titanium dioxide, cement and pharmacy industries
Summary:
DJ-10 X-ray small diffractometer is mainly used for phase analysis of powders, solids and similar paste materials. The device is small in size, light in weight, low in power consumption, and can quickly calibrate and test samples. The measurement accuracy of the position is 0.001°, which is used for computer control, and the data collection and timely processing can be directly seen under the Windows.
Applications:
DJ-10 XRD mainly used for the phase characterization, quantitative analysis, crystal structure, material structure, crystal orientation, macroscopic and microscopic stress determination, crystal size, crystallinity determination, etc. By the principle of Scherrer, High precision is assured. Widely used in geology, oceanology, biology, chemistry, nuclear station research as well as industrial and institute research.
DJ-10 XRD mainly used to perform the phase analysis of powder, solid, paste related state materials.
The size is small, light, low power consumption, calibrating and analysis could be performed fast diffraction peak accuracy 0.001°,PC controlled to display data collecting and for prompt measures.
Parameters:
X-ray Tube | Tube Type: Ceramic or glass tube are optional Target: Cu, Fe, Co, Cr, Mo, Ti, W Default: Cu Focus Size: 1×10 mm Power: 2KW |
X-ray Generator | Tube voltage: 10-30KV or 10-40KV Tube current: 5-20Ma or 5-30mA Tube current: 5-20Ma or 5-30mA Filament current:: DC 0-3A Stability: ±0.01%, Voltage deviation 10% Max power: 600W or 1200W |
Vertical Goniometer | Radius: 150mm Scan Type: θ/2θ linkage 2θ Scan range: -3°~150° 2θ Detecting range: +2°~150° Positioning speed: 1000°/min (2θ) Scan speed: 0.01~100°/min 2θ Min stepping: 0.0002° Accuracy: 0.001° 2θ Repeatability accuracy: 0.0005° |
Slit | Divergent slit (DS): θ shaft changeable slit(Max 4.2°) Scatter slit(SS): 0.5°/1°/2° Receiving slit(RS): 0.1mm/0.2mm/0.3mm/0.4mm Soller slit: ±2.5° X-ray extraction angle: 6° |
Proportional Detector (PC) | Max counting: 1×106 cps/s; Spectrum resolution: ≤20%; Counter voltage: 0-2100V: High-voltage stability above 0.005% |
Cooling Water System | Supply Power:220V/50HZ Flow:3L/min Pressure: 0.1Mpa-0.30.1Mpa System temperature: 18-30°, control accuracy: ±1° Control panel light: Power, Cooling, Flow indicator |
Measurement and Weight | Measurement: 740×600×630mm Weight: 75Kg |