X Ray Diffraction XRD Price Manufacturer
USD $80,000 - $100,000 /Set
Min.Order:1 Set
Wuxi Jinyibo Instrument Technology Co., Ltd.
DJ-3500 X-ray Diffractometer
Combined Multi-functional X-ray Diffractometer
One and many phase identification of unknown sample
Quantitative analysis of the phase in the mixed sample
Crystal structure analysis
The crystal structure change of the abnormal condition.
Thin film sample analysis
Analysis of micro area sample.
Texture and stress analysis of metallic materials.
Applications:
DJ series multi-function X-ray diffractometer (XRD) is an analysis instrument for studying and identifying the composition and crystal structure of materials and materials by X-ray diffraction principle. It can reveal the chemical composition and crystallization of various types of natural and artificial materials, details such as learning the microstructure.
Main Application Field
Clay minerals, cement building materials, environmental dust, food inspection, chemical products, pharmaceutical testing, asbestos, polymers, steel, non-ferrous metals, machinery, shipbuilding, welding, automotive, silicate, ceramics, cement, glass, catalysts, electrical appliances Components, electronic materials, magnetic materials, superconducting materials, building materials, fiber, paper, agricultural chemistry, dyes, pigments, coating, ecological materials, petroleum, coal, electricity, ore, soil, rock, environment, etc.
Parameters:
DJ-3500 X-ray Diffractometer Specification | |
X-ray Tube(domestic or imported) | Target Optional targets such as Cu, Fe, Co, Cr, Mo, W (metal or ceramic optional) Focus Size: 1 x 10 mm 2or0.4 x 14m m2 Rated powor:2.4kW or 2 7kW (Galss tube as default, ceramic tube or metal cermic tube techno) |
X-ray Generator (PLC control) | Maximum output power: 3kW high voltage generator(domestic /import) X-ray tube voltage: 10-60kV, 0.1kV/step X-ray tube current: 5-50mA, 0.1mA/step Output stability: ≤0.01% (power supply fluctuation ±10%) |
Goniometer | Goniometer structure vertical goniometer θs-θd structure (sample fixed) Goniometer scanning radius: Standard 225mm (150-285mm continuously adjustable) Scanning range: -110°-160° Scan speed: 0.006° -120° /min Positioning speed: 1200°/min Drive mode: θs-θd linkage, θs or θd single Scan mode: Stepping, continuous, segmentation, transmission scanning Minimum step angle: 0.0001° measurement accuracy: ≤0.001° 20 angle repeatability: 0.0002° |
Recording Control Unit | Detector Type: SDD or SC Maximum linear count rate: up to 1X107cps (noise≤1cps) Energy resolution: ≤5% SDD≤50% SC Working mode: PLC automatic control differential, integral mode conversion PLC automatically performs PHA dead time correction Detector high voltage 0-1100 VDC continuously adjustable Voltage stability: 0.005% |
Safety Protection Alarm
| KV and mA are too high or too low, overload protection, no water alarm X-ray tube over-temperature and other multiple protection, to prevent radiation leakage, protective door interlock protection and platform lead shielding protection |
X-ray leakage | ≤0.1µSv/h (maximum power of X-ray tube, without subtracting the background) |
Stability | ≤0.5% (40kV, 40mA, continuous operation for 8 hours) |
Dimensions (Main Body) | 1170mmx870mmx1800mm (LongthxWidthxHeight) |
Transmission | Industrial Ethernet |