DC-6 of Refrigerated Thermostatic Water/Oil Bath And Heating Circulators
USD $600 - $1,100 /Piece
Min.Order:1 Piece
Shanghai Drawell Scientific Instrument Co., Ltd.
DLK-5003 Rapid Low Temperature Cooling Circulating Water Bath
SC-25 Constant Temperature Digital Control Thermostatic Water Bath
DC-3006 Lab Use Refrigerated Water Bath With Heating Circulators
DC-0510 Refrigerated Thermostatic Water Bath And Heating Circulators
DC-1010 Refrigerated Thermostatic Water Bath And Heating Circulators
SC-15 Digital Control Laboratory Use Constant Temperature Water Bath
DC Series of Refrigerated Thermostatic Bath and Heating Circulators
The series of Refrigerated thermostatic bath has adopted the latest international advanced CFC-free refrigeration system. The main components used are imported and the performance is stable and reliable. It is widely used in research institutes, universities, corporate quality control departments and industrial sectors relating to petroleum, chemical engineering, electronic instruments, physics, chemistry, bio-engineering, medicine and health, life science, light industry and food, materials testing and chemical analysis etc. It is used to put trial samples or newly made products to a constant-temperature test. It can also be used as a heat source or cold source for a direct heating or cooling and auxiliary heating or cooling.
Features:
Using environmentally friendly CFC-free refrigeration technology to meet the requirements of environmental protection.
Using high-quality full-enclosed air-cooled compressor cooling system, low noise
Full-enclosed air-cooled compressor cooling system with thermal overload protection automatically
with a power-off protection function, automatically delayed for three minutes
using a TFT touch screen, easy to understand working condition
Intelligent PID automatically adjust control function
Upper and lower temperature alarm can be set
with over heat alarm system to ensure the safety apparatus
Inner high-quality stainless steel material
with external circulating pump, can be established the second constant temperature field outside the bath
Cold liquid can be cited outside the tank, cooling the experimental container outside the bath
Using analogue theory, automatic identify the difference between set temperature and the ambient temperature, to confirm whether a single heating or cooling heating work simultaneously to achieve the energy saving
Model |
Temperature Range (°C) |
Tempe rapture Stability (°C) |
Display Resolution (mm3) |
Tank Size (mm3) |
Pump Flow L/ min |
Top Opening Dimen (mm2) |
Head of Delivery (M) |
Drainage |
SDC-6 |
-5~100 |
±0.05 |
0.1 |
260×200×140 |
0-20 |
180×140 |
5 |
√ |
DC-1006 |
-10~100 |
±0.05 |
0.1 |
260×200×140 |
0-20 |
180×140 |
5 |
√ |
DC-2006 |
-20~100 |
±0.05 |
0.1 |
260×200×140 |
0-20 |
180×140 |
5 |
√ |
DC-3006 |
-30~100 |
±0.1 |
0.1 |
260×200×140 |
0-20 |
180×140 |
5 |
√ |
DC-4006 |
-40~100 |
±0.1 |
0.1 |
260×200×140 |
0-20 |
180×140 |
5 |
√ |
DC-0510 |
-5~100 |
±0.05 |
0.1 |
260×200×200 |
0-20 |
180×140 |
5 |
√ |
DC-1010 |
-10~100 |
±0.05 |
0.1 |
260×200×200 |
0-20 |
180×140 |
5 |
√ |
DC-2010 |
-20~100 |
±0.05 |
0.1 |
260×200×200 |
0-20 |
180×140 |
5 |
√ |
DC-3010 |
-30~100 |
±0.1 |
0.1 |
260×200×200 |
0-20 |
180×140 |
5 |
√ |
DC-4010 |
-40~100 |
±0.1 |
0.1 |
260×200×200 |
0-20 |
180×140 |
5 |
√ |
DC-0515 |
-5~100 |
±0.05 |
0.1 |
300×250×200 |
0-20 |
235×160 |
5 |
√ |
DC-1015 |
-10~100 |
±0.05 |
0.1 |
300×250×200 |
0-20 |
235×160 |
5 |
√ |
DC-2015 |
-20~100 |
±0.05 |
0.1 |
300×250×200 |
0-20 |
235×160 |
5 |
√ |
DC-3015 |
-30~100 |
±0.1 |
0.1 |
300×250×200 |
0-20 |
235×160 |
5 |
√ |
DC-4015 |
-40~100 |
±0.1 |
0.1 |
300×250×200 |
0-20 |
235×160 |
5 |
√ |
DC-0530 |
-5~100 |
±0.05 |
0.1 |
440×325×200 |
0-20 |
310×280 |
5 |
√ |
DC-1030 |
-10~100 |
±0.05 |
0.1 |
440×325×200 |
0-20 |
310×280 |
5 |
√ |
DC-2030 |
-20~100 |
±0.05 |
0.1 |
440×325×200 |
0-20 |
310×280 |
5 |
√ |
DC-3030 |
-30~100 |
±0.1 |
0.1 |
440×325×200 |
0-20 |
310×280 |
5 |
√ |
DC-1030 |
-10~100 |
±0.05 |
0.1 |
440×325×200 |
0-20 |
310×280 |
5 |
√ |
DC-2030 |
-20~100 |
±0.05 |
0.1 |
440×325×200 |
0-20 |
310×280 |
5 |
√ |
DC-3030 |
-30~100 |
±0.1 |
0.1 |
440×325×200 |
0-20 |
310×280 |
5 |
√ |
DCW-1015 |
-10~100 |
±0.05 |
0.1 |
280×250×220 |
0-20 |
235×160 |
5 |
√ |
DCW-2008 |
-20~100 |
±0.05 |
0.1 |
280×250×140 |
0-20 |
235×160 |
5 |
√ |
DCW-3506 |
-35~100 |
±0.1 |
0.1 |
260×200×140 |
0-20 |
180×140 |
5 |
√ |
DCW-3510 |
-35~100 |
±0.1 |
0.1 |
250×200×200 |
0-20 |
180×140 |
5 |
√ |
DCW-0506 |
-6~100 |
±0.05 |
0.1 |
260×200×140 |
0-20 |
180×140 |
5 |
√ |
DCW-4006 |
-40~100 |
±0.1 |
0.1 |
260×200×140 |
0-20 |
180×140 |
5 |
√ |