Drawell Automatic  laboratory equipment Semi Automatic biochemistry analyzer
Drawell Automatic  laboratory equipment Semi Automatic biochemistry analyzer
Drawell Automatic  laboratory equipment Semi Automatic biochemistry analyzer
Drawell Automatic  laboratory equipment Semi Automatic biochemistry analyzer
Drawell Automatic  laboratory equipment Semi Automatic biochemistry analyzer
Drawell Automatic  laboratory equipment Semi Automatic biochemistry analyzer

Drawell Automatic laboratory equipment Semi Automatic biochemistry analyzer

USD $39,200 - $39,200 /Piece

Min.Order:1 Piece

Supply Ability:
500 Piece / Pieces per Month
Port:
shanghai
Payment Terms:
T/T Credit Card

Quick Details View All >

Brand Name:
DRAWELL
Place of Origin:
Shanghai, China
Model Number:
Drawell- Emerald

Shanghai Drawell Scientific Instrument Co., Ltd.

Business Type: Association
Main Products: Spectrophotometer ,Environmental Analyser

Product Details

Drawell-Emerald Auto Biochemistry Analyzer (800T/H)

 

Parameter:

1. 800 test per hour,160 cuvettes

2. 180 sample position.

3. 200 refrigerated reagent position.

4. optical grating

 

Features:

1. Fully automated, Discrete, Random access,STAT priority,real-time dual wavelength.

2. Total open setting of items, supported different reagents from different countries.

3. Reversed optics and imported photo sensor make sure the precision of detection results.

4. Microsring injector imported from Germany assures the veracity of a trace of samples, 

sample step by 0.1 UL, reagent step by0.5 UL

5. 24 hour non-stop working, convenient emergency function with inserting emergency at random.

6. Implementing analysis of ultra-trace reaction solution to 100 UL, and saving more reagents.

7. Discrete cuvette, preventing from cross-infection, and be washed and reused, making sure accurate result and save cost.

8. Perfect self-detection function makes sure the analyzer in order and accurate result.

9. Software is easy to learn and use. And test report can be printed.

10. Perfect function of quality control management is convenient for users to manage the clinical test result.

11. Detecting in the whole reaction process with reaction curve, convenient for users to monitor thoroughly and scientifically analyze the detection data.

12. Supporting software can implement the function of detecting surplus reagent through liquid level induction of reagent probe.

 

 

Overall 

Performance 

Model 

Drawell-EMERALD 

Type 

Discrete, Fully automatic 

Throughput 

800T/H 

Analysis Method 

End-point, Fixed-time,Rate,etc 

Programming Items 

programmable for any test items 

Certification 

CE, FDA, ISO9001, ISO14001, ISO13485 

Sample unit 

Sample Position

180 samples, double disk design, including 60 samples for 

calibration/quality dribbling refrigerated

Sample Tubes

Original blood collection tube,micro tube,plastic tube,etc.

Sample Types 

Serum,plasma,urine,etc.

Sample Volume 

2ul ~70ul (0.1ul stepping) 

Sample Probe 

Having liquid level induction function, 

ensuring the accuracy of adding sample 

Probe Cleaning 

Automatic washing both interior and exterior ,

cross contamination rate < 0.1%

Analysis Items 

analyzing maximally 100 items at the same time 

Reagent unit 

Reagent Position 

200 reagent positions, dual-tray design

Wash Solution

Washing solution can be installed in any position, 

including needle, stir bar washing solution and 

water bath disinfectant

Reagent Volume 

20-350ul, 0.5ul increment

Temperature Control 

continuous2~8℃cooling within 24 hours 

Reagent Probe 

Having liquid level induction function, 

ensuring the accuracy of adding reagent. 

Inventory checking 

Probe cleaning 

Automatic washing both interior and exterior 

Reaction unit 

Reaction Volume

150-550ul

Reaction Temperature

37℃

Temperature system

Water bath,Real-time temperature display

Cuvettes 

160 positions with permanent hard glass cuvettes 

(optical path length 5mm) 

Stirrer 

Independent stir bar, nanotechnology, highly polished, 

automatic frequency conversion

Cleaning 

automatic water cleaning and drying system 

System Adjustment 

System can record the blank value and get more accurate 

result by deducting blank base value of each cuvette 

Optical System 

Light Source 

Halogen lamp, lamp can be auto sleep and wake up

Receiver 

Holographic flat field concave grating diode array detection

Wavelength Range 

16 wavelengths from 340 to 800nm

Linear Range 

-0.3000~3.3000 Abs

Stray light

< 0.1% or Abs > 3.0

Calibration and QC 

Calibration Method

Linear calibration:K factor,two- and multiple linear  Nonlinear

Calibration:spline,polynomial,Logarithm,etc. 

Quality Control 

Auto QC,cooled QC positions

Software 

Emergency Function 

Emergency sample can be placed in the sample tray at any time 

Software 

Windows XP (SP3) / Win 7 

Online

Full bi-directional communication possible

Data Processing 

Having reaction curve detection and data display function 

in the whole process 

Others 

Water consumption

Deionized water , <45 L/hour

Power Supply 

110-240V ,50Hz ,<1.5KW

Dimension 

1508×865.5×1204mm

Weight 

400Kg

 

Drawell-Diamond Auto Biochemistry Analyzer (400 T/H)

 

1. Fully automatic, Discrete, Random access

2.400 T/H, 60/90 sample position and 120 reusable cuvettes.

3. 90 refrigerated reagent tray (R1:45 R2:45), 24 hour working.

4. Reversed optics and imported photo sensor, ensuring the precision of detection results.

5. Precision dispense pumps assures the accuracy of adding sample volume, sample volume step by 0.1μl, reagent volume step by 1μl.

 

 

Overall

Performance

Model

Drawell-DIAMOND

Type

discrete, fully automatic

Throughput

400 T/H

Analysis Method

End-point, Fixed-time, Rate

Programming Items

programmable for any test items

Certification

CE, FDA, ISO9001, ISO14001, ISO13485

 

Sample unit

Sample Settings

60/90 sample positions, including calibration, quality control and emergency.

Sample Volume

2ul ~50ul (0.1ul stepping)

Sample Probe

Having liquid level induction function.

Probe cleaning

Automatic washing both interior and exterior

Analysis Items

analyzing maximally 45 items at the same time

 

Reagent unit

Reagent Position

R1:45 R2:45 total 90 refrigerated reagent position

Reagent Volume

R1:25~300ul, R2:10~150ul (1ul stepping), supporting reagent from different brand

Temperature Control

continuous 2C~8Ccooling within 24 hours

Reagent Probe

Having liquid level induction function

Probe cleaning

Automatic washing both interior and exterior

Reaction unit

Reaction Time

10 minutes

Temperature

37C±0.1C

Cuvettes

120 reaction cuvettes (optical path length 6mm)

Mixer

after injecting reagent and sample, blending immediately

Cleaning

automatic water cleaning and drying system

System Adjustment

System record the blank value and get more accurate result by deducting blank base value of each cuvette

Optical System

Light Source

12V/30W halogen-tungsten lamp, 2000 hours

Receiver

8 precision photo receivers

Wavelength Range

340,405,450,510,546,578,630,700mm

Calibration and QC

Calibration

one-point,multi-point

Linear Range

0.000~2.500Abs

Quality Control

Inserting quality control at random.

 

Software

Emergency Function

emergency sample can be arranged at any time

Software

Windows XP or 7, sample and easy to operate

Data Processing

Having reaction curve detection and data display function in whole process.

Others

Power Supply

AC220V+22V/50Hz+1Hz

Dimension

1070mm×910mm×1230mm (W*D*H)

Weight

180kg

 

 

Accessories:

Name

Unit

Quantity

Sample cup

One

1

Cuvettes

Pack(120 units)

1 pack

Reagent Probe

One

1

Sample Probe

One

1

Mixer probe

One

1

Fuse

One

1

Halogen lamp

One

1

 

 

Drawell-Crystal Auto Biochemistry Analyzer (300 T/H)

 

1. Fully automatic, Discrete, Random access 

2.300 test per hour, 45 reagent position, 60 sample position and 120cuvettes. 

3. Refrigerated reagent tray, 24 hour working. 

4. Reversed optics and imported photo sensor, ensuring the precision of detection results. 

5. Precision dispense pumps assures the accuracy of adding sample volmue, sample volume step by 0.1uL, reagent volume step by 1uL. 

 

Overall

Performance

Model

Drawell-CRYSTAL

Type

discrete, fully automatic

Throughput

300T/H

Analysis Method

End-point, Fixed-time,Rate

Programming Items

programmable for any test items

Certification

CE, FDA, ISO9001, ISO14001, ISO13485

 

Sample unit

Sample Settings

60 sample positions, including calibration, quality control and emergency, primary tubes and serum is available

Sample Volume

2ul ~50ul (0.1ul stepping)

Sample Probe

Having liquid level induction function, ensuring the accuracy of adding sample

Probe cleaning

Automatic washing both interior and exterior

Analysis Items

analyzing maximally 45 items at the same time

 

Reagent unit

Reagent Position

45 low-temperature refrigerated reagent position

Reagent Volume

R1:25~300ul, R2:10~150ul (1ul stepping), supporting reagent from different countries

Temperature Control

continuous 2C~8Ccooling within 24 hours

Reagent Probe

Having liquid level induction function, ensuring the accuracy of adding reagent. Inventory checking

Probe cleaning

Automatic washing both interior and exterior

Reaction unit

Reaction Time

10 minutes

Temperature Control

37C±0.1C

Cuvettes

120 independent reaction cuvettes (optical path length 6mm)

Stirrer

after injecting reagent and sample, blending immediately

Cleaning

automatic water cleaning and drying system

System Adjustment

System can record the blank value and get more accurate result by deducting blank base value of each cuvette

Optical System

Light Source

12V/30W halogen-tungsten lamp, 2000 hours

Receiver

8 precision photo receivers

Wavelength Range

340,405,450,510,546,578,630,700mm

Calibration and QC

Calibration

one-point,multi-point

Linear Range

0.000~2.500Abs

Quality Control

Inserting quality control at random.6 quality controls can be reached with one item

 

Software

Emergency Function

emergency sample can be placed in the sample tray at any time

Software

Windows 2000 or Windows XP or above, sample and easy to operate

Data Processing

Having reaction curve detection and data display function in the whole process

Others

Power Supply

AC220V+22V 50Hz+1Hz

Dimension

1020mm×830mm×1200mm (W*D*H)

Weight

150kg

 

 

 

Drawell Automatic  laboratory equipment Semi Automatic biochemistry analyzerDrawell Automatic  laboratory equipment Semi Automatic biochemistry analyzerDrawell Automatic  laboratory equipment Semi Automatic biochemistry analyzerDrawell Automatic  laboratory equipment Semi Automatic biochemistry analyzerDrawell Automatic  laboratory equipment Semi Automatic biochemistry analyzerDrawell Automatic  laboratory equipment Semi Automatic biochemistry analyzerDrawell Automatic  laboratory equipment Semi Automatic biochemistry analyzer

products profile

Drawell Automatic  laboratory equipment Semi Automatic biochemistry analyzer 

case

Drawell Automatic  laboratory equipment Semi Automatic biochemistry analyzer 

Company Profile

Drawell Automatic  laboratory equipment Semi Automatic biochemistry analyzer 

exhibition

Drawell Automatic  laboratory equipment Semi Automatic biochemistry analyzer 

packing

Drawell Automatic  laboratory equipment Semi Automatic biochemistry analyzer 

FAQ

Drawell Automatic  laboratory equipment Semi Automatic biochemistry analyzer 

payment methods

Drawell Automatic  laboratory equipment Semi Automatic biochemistry analyzer 

Contact Supplier

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Hi~