Drawell Automatic laboratory equipment Semi Automatic biochemistry analyzer
USD $39,200 - $39,200 /Piece
Min.Order:1 Piece
Shanghai Drawell Scientific Instrument Co., Ltd.
Drawell-Emerald Auto Biochemistry Analyzer (800T/H)
Parameter:
1. 800 test per hour,160 cuvettes
2. 180 sample position.
3. 200 refrigerated reagent position.
4. optical grating
Features:
1. Fully automated, Discrete, Random access,STAT priority,real-time dual wavelength.
2. Total open setting of items, supported different reagents from different countries.
3. Reversed optics and imported photo sensor make sure the precision of detection results.
4. Microsring injector imported from Germany assures the veracity of a trace of samples,
sample step by 0.1 UL, reagent step by0.5 UL
5. 24 hour non-stop working, convenient emergency function with inserting emergency at random.
6. Implementing analysis of ultra-trace reaction solution to 100 UL, and saving more reagents.
7. Discrete cuvette, preventing from cross-infection, and be washed and reused, making sure accurate result and save cost.
8. Perfect self-detection function makes sure the analyzer in order and accurate result.
9. Software is easy to learn and use. And test report can be printed.
10. Perfect function of quality control management is convenient for users to manage the clinical test result.
11. Detecting in the whole reaction process with reaction curve, convenient for users to monitor thoroughly and scientifically analyze the detection data.
12. Supporting software can implement the function of detecting surplus reagent through liquid level induction of reagent probe.
Overall Performance | Model | Drawell-EMERALD | ||
Type | Discrete, Fully automatic | |||
Throughput | 800T/H | |||
Analysis Method | End-point, Fixed-time,Rate,etc | |||
Programming Items | programmable for any test items | |||
Certification | CE, FDA, ISO9001, ISO14001, ISO13485 | |||
Sample unit | Sample Position | 180 samples, double disk design, including 60 samples for calibration/quality dribbling refrigerated | ||
Sample Tubes | Original blood collection tube,micro tube,plastic tube,etc. | |||
Sample Types | Serum,plasma,urine,etc. | |||
Sample Volume | 2ul ~70ul (0.1ul stepping) | |||
Sample Probe | Having liquid level induction function, ensuring the accuracy of adding sample | |||
Probe Cleaning | Automatic washing both interior and exterior , cross contamination rate < 0.1% | |||
Analysis Items | analyzing maximally 100 items at the same time | |||
Reagent unit | Reagent Position | 200 reagent positions, dual-tray design | ||
Wash Solution | Washing solution can be installed in any position, including needle, stir bar washing solution and water bath disinfectant | |||
Reagent Volume | 20-350ul, 0.5ul increment | |||
Temperature Control | continuous2~8℃cooling within 24 hours | |||
Reagent Probe | Having liquid level induction function, ensuring the accuracy of adding reagent. Inventory checking | |||
Probe cleaning | Automatic washing both interior and exterior | |||
Reaction unit | Reaction Volume | 150-550ul | Reaction Temperature | 37℃ |
Temperature system | Water bath,Real-time temperature display | |||
Cuvettes | 160 positions with permanent hard glass cuvettes (optical path length 5mm) | |||
Stirrer | Independent stir bar, nanotechnology, highly polished, automatic frequency conversion | |||
Cleaning | automatic water cleaning and drying system | |||
System Adjustment | System can record the blank value and get more accurate result by deducting blank base value of each cuvette | |||
Optical System | Light Source | Halogen lamp, lamp can be auto sleep and wake up | ||
Receiver | Holographic flat field concave grating diode array detection | |||
Wavelength Range | 16 wavelengths from 340 to 800nm | |||
Linear Range | -0.3000~3.3000 Abs | |||
Stray light | < 0.1% or Abs > 3.0 | |||
Calibration and QC | Calibration Method | Linear calibration:K factor,two- and multiple linear Nonlinear Calibration:spline,polynomial,Logarithm,etc. | ||
Quality Control | Auto QC,cooled QC positions | |||
Software | Emergency Function | Emergency sample can be placed in the sample tray at any time | ||
Software | Windows XP (SP3) / Win 7 | |||
Online | Full bi-directional communication possible | |||
Data Processing | Having reaction curve detection and data display function in the whole process | |||
Others | Water consumption | Deionized water , <45 L/hour | ||
Power Supply | 110-240V ,50Hz ,<1.5KW | |||
Dimension | 1508×865.5×1204mm | |||
Weight | 400Kg |
Drawell-Diamond Auto Biochemistry Analyzer (400 T/H)
1. Fully automatic, Discrete, Random access
2.400 T/H, 60/90 sample position and 120 reusable cuvettes.
3. 90 refrigerated reagent tray (R1:45 R2:45), 24 hour working.
4. Reversed optics and imported photo sensor, ensuring the precision of detection results.
5. Precision dispense pumps assures the accuracy of adding sample volume, sample volume step by 0.1μl, reagent volume step by 1μl.
Overall Performance | Model | Drawell-DIAMOND | ||||
Type | discrete, fully automatic | |||||
Throughput | 400 T/H | |||||
Analysis Method | End-point, Fixed-time, Rate | |||||
Programming Items | programmable for any test items | |||||
Certification | CE, FDA, ISO9001, ISO14001, ISO13485 | |||||
Sample unit | Sample Settings | 60/90 sample positions, including calibration, quality control and emergency. | ||||
Sample Volume | 2ul ~50ul (0.1ul stepping) | |||||
Sample Probe | Having liquid level induction function. | |||||
Probe cleaning | Automatic washing both interior and exterior | |||||
Analysis Items | analyzing maximally 45 items at the same time | |||||
Reagent unit | Reagent Position | R1:45 R2:45 total 90 refrigerated reagent position | ||||
Reagent Volume | R1:25~300ul, R2:10~150ul (1ul stepping), supporting reagent from different brand | |||||
Temperature Control | continuous 2C~8Ccooling within 24 hours | |||||
Reagent Probe | Having liquid level induction function | |||||
Probe cleaning | Automatic washing both interior and exterior | |||||
Reaction unit | Reaction Time | 10 minutes | Temperature | 37C±0.1C | ||
Cuvettes | 120 reaction cuvettes (optical path length 6mm) | |||||
Mixer | after injecting reagent and sample, blending immediately | |||||
Cleaning | automatic water cleaning and drying system | |||||
System Adjustment | System record the blank value and get more accurate result by deducting blank base value of each cuvette | |||||
Optical System | Light Source | 12V/30W halogen-tungsten lamp, 2000 hours | ||||
Receiver | 8 precision photo receivers | |||||
Wavelength Range | 340,405,450,510,546,578,630,700mm | |||||
Calibration and QC | Calibration | one-point,multi-point | Linear Range | 0.000~2.500Abs | ||
Quality Control | Inserting quality control at random. | |||||
Software | Emergency Function | emergency sample can be arranged at any time | ||||
Software | Windows XP or 7, sample and easy to operate | |||||
Data Processing | Having reaction curve detection and data display function in whole process. | |||||
Others | Power Supply | AC220V+22V/50Hz+1Hz | ||||
Dimension | 1070mm×910mm×1230mm (W*D*H) | |||||
Weight | 180kg |
Accessories:
Name | Unit | Quantity |
Sample cup | One | 1 |
Cuvettes | Pack(120 units) | 1 pack |
Reagent Probe | One | 1 |
Sample Probe | One | 1 |
Mixer probe | One | 1 |
Fuse | One | 1 |
Halogen lamp | One | 1 |
Drawell-Crystal Auto Biochemistry Analyzer (300 T/H)
1. Fully automatic, Discrete, Random access
2.300 test per hour, 45 reagent position, 60 sample position and 120cuvettes.
3. Refrigerated reagent tray, 24 hour working.
4. Reversed optics and imported photo sensor, ensuring the precision of detection results.
5. Precision dispense pumps assures the accuracy of adding sample volmue, sample volume step by 0.1uL, reagent volume step by 1uL.
Overall Performance | Model | Drawell-CRYSTAL | ||||
Type | discrete, fully automatic | |||||
Throughput | 300T/H | |||||
Analysis Method | End-point, Fixed-time,Rate | |||||
Programming Items | programmable for any test items | |||||
Certification | CE, FDA, ISO9001, ISO14001, ISO13485 | |||||
Sample unit | Sample Settings | 60 sample positions, including calibration, quality control and emergency, primary tubes and serum is available | ||||
Sample Volume | 2ul ~50ul (0.1ul stepping) | |||||
Sample Probe | Having liquid level induction function, ensuring the accuracy of adding sample | |||||
Probe cleaning | Automatic washing both interior and exterior | |||||
Analysis Items | analyzing maximally 45 items at the same time | |||||
Reagent unit | Reagent Position | 45 low-temperature refrigerated reagent position | ||||
Reagent Volume | R1:25~300ul, R2:10~150ul (1ul stepping), supporting reagent from different countries | |||||
Temperature Control | continuous 2C~8Ccooling within 24 hours | |||||
Reagent Probe | Having liquid level induction function, ensuring the accuracy of adding reagent. Inventory checking | |||||
Probe cleaning | Automatic washing both interior and exterior | |||||
Reaction unit | Reaction Time | 10 minutes | Temperature Control | 37C±0.1C | ||
Cuvettes | 120 independent reaction cuvettes (optical path length 6mm) | |||||
Stirrer | after injecting reagent and sample, blending immediately | |||||
Cleaning | automatic water cleaning and drying system | |||||
System Adjustment | System can record the blank value and get more accurate result by deducting blank base value of each cuvette | |||||
Optical System | Light Source | 12V/30W halogen-tungsten lamp, 2000 hours | ||||
Receiver | 8 precision photo receivers | |||||
Wavelength Range | 340,405,450,510,546,578,630,700mm | |||||
Calibration and QC | Calibration | one-point,multi-point | Linear Range | 0.000~2.500Abs | ||
Quality Control | Inserting quality control at random.6 quality controls can be reached with one item | |||||
Software | Emergency Function | emergency sample can be placed in the sample tray at any time | ||||
Software | Windows 2000 or Windows XP or above, sample and easy to operate | |||||
Data Processing | Having reaction curve detection and data display function in the whole process | |||||
Others | Power Supply | AC220V+22V 50Hz+1Hz | ||||
Dimension | 1020mm×830mm×1200mm (W*D*H) | |||||
Weight | 150kg |