Medical electric plaster saw cast cutter orthopedic sports medicine 110V 12500rpm/min
Negotiable /Piece
Min.Order:1 Piece
Medical Use Portable Oxygen Concentrator Generator 110V/220V Oxygenation Oxygen
good quality low price Medical Digital Baby Non Contact Forehead Infrared Thermometer
non contact medical infrared forehead digital meat baby thermometer
ozone machine/ozone therapy machine/portable ozone therapy machine
Car Portable 90% purity oxygen machine Oxygen concentrator 5L flow
Description
The electrically operated gypsum saws through the saw blade swinging sawing gypsum,in use,even if the saw blade will contact the patient skin not to create cuts.the electrical machinery uses the double insulation protective device,has guaranteed the safety of patient.
Scope of application
The orthopedic products for fixed reset,remove the plaster bandages used.
Main technical data:
1.Voltage:AC 110V/60HZ
2.Input power 125VA
3.Non-load Frequency more than 12500r/min
4.Non-load Speed ≤75dB
5.Motor Winding insulation class E Class
Products Classification:
1.Anti-shock type,degree and protection against harmful into the liquid level points:medical saw is II type.B is common tyoe.
2.Divided by the work of system: medical electric plaster saw is running short.
Application and attention:
1.Before use, check whether the formation of saw blade,missing teeth,mounting, installing the saw blade when the blade shaft to be fixed,embedded with the pull head axis position of the flat side, with the other nuts in front of the saw blade wrench removed, exit concave sleeve and saw blade,saw blade and then put the other tightly.check the motor ventilation road,should be kept clear to prevent foreign objects clogging, resulting in poor ventilation,resulting in excessive temperature rise of the motor work,or even burn the motor.
2.When used,not used much pressure, when the blade got stuck in the plaster bandage,it should cut off the power slowly withdraw.not to open when the power switch off, easy to damage the motor.
3.The temperature of the motor housing using the increase over time,such as hot case temperature should be found to be suspended,wait to cool before using, or likely to cause motor overheating and burning.
4.When have abnormal sound, vibration is too large,please maintenance in time.
5.Should be wipe clean the plaster saw after operation, kept in dry places(relative humidity less than 80%, non corrosive gas environment)to prevent water and damage and stumble.
Include:
1 x Medical electric plaster saw
2 x Circular saw blade
1 x Fan-shaped saw blade
1 x Wrench
1 x Carry box
1 x Manual