Acrel ADW400 wireless energy meter
Acrel ADW400 wireless energy meter
Acrel ADW400 wireless energy meter
Acrel ADW400 wireless energy meter
Acrel ADW400 wireless energy meter
Acrel ADW400 wireless energy meter

Acrel ADW400 wireless energy meter

USD $180 - $180 /Set

Min.Order:1 Set

Supply Ability:
1000 Set / Sets per Month
Payment Terms:
T/T Credit Card

Quick Details View All >

Brand Name:
Acrel
Place of Origin:
China
Model Number:
ADW
Phase:
Three Phase
Output Voltage:
380V
Operating Temperature:
-20℃~+55℃

Jiangsu Acrel Electrical Manufacturing CO.,LTD

Business license
Business Type: Manufacturer
Wuxi Jiangsu China
Main Products: power sensor ,programmable power meter ,DC power analyzer ,Data center monitor device ,Din rail energy meter ,Isolated power supply ,wireless temperature sensor ,IOT energy meter ,split core current transformer

Product Details

 

Product Description

ADW400 power monitoring module is mainly used to measure three-phase active power of low-voltage network. At the same time, it can select the current input of the largest four loops. It has RS485 communication and 470MHz wireless communication functions, which is convenient for users to monitor, collect and manage electricity. It can be flexibly installed in the distribution box to realize the measurement, statistics and analysis of individual electric energy in different regions and loads.

Naming rules for ADW400 main module

 

Naming rules for mutual inductor

Model and specification

Electrical performance

Electrical performance

Working  environment conditions

Outline dimensions and installation instructions

Installing description

Installation mode of puncture clip

 

Installation notes:

1.During the installation of puncture clip, it should be avoided to break it by force;

2.After the installation of the puncture clamp, let the equipment side run full load for more than 1 hour, and measure the temperature of the cable at the installation point, which should not exceed 80℃.

wiring explain

The terminal is shown in the following figure,the current signal lines of A,B and C transformers are respective connected to IA(input),IA*(output);IB(input),IB*(output)and IC(input),IB(output);A, B and C three-phase voltage signal lines are respective connected to UA, UB and UC terminals ;N is connected to UN terminals.

Operation and Display

There are eight LED lights on the front of the front of the casing.They are:“DI1”,“DI2”,“DI3”,“DI4”,“UA”,“UB”,“UC”,“COM”.

When external switching input is available,“DI1”,“DI2”,“DI3”,“DI4”four lights on

 When there is an external voltage input,“UA”,“UB”,“UC”three lights on.

COM has indicator flashing, when the red light flickers, indicating that the instrument carries out "LORA" communication, when the green light flickers, indicating that the instrument carries out RS485 communication.

 

Communication protocol

The instrument adopts MODBUS-RTU protocol or DL/645 protocol. For specific protocol formats, please refer to the relevant protocol standards.

 

Troubleshooting of Common Faults

The instrument does not turn on after installation, or a voltage indicator does not turn on.

 

Instrument wireless communication failure

Please connect the instrument RS485 interface with USB to 485 serial port first, read the parameters in the table through communication, confirm whether the parameters in the table are the same as the wireless configuration of the upper main station (channel and spread spectrum factor). If different, please modify the wireless parameters of the instrument to be consistent with the main station before re-testing; if the same, it may be the instrument and the main station phase. If the distance is too far or the interference is serious, we can try to use the external sucker antenna, or consider adding a new wireless main station nearby, and then test it.

 

Company Information


Acrel ADW400 wireless energy meter

 

Packaging & Shipping

 Acrel ADW400 wireless energy meter

 

Our Services

 Acrel ADW400 wireless energy meter

 

FAQ

Common errors check and solve

 

1 The meter do not light after powered, or one path of voltage indicator do not light.

 

Suggestion: Please turn the screw to ensure that the meter needle has been punctured and contacted with the cable inner
conductor cable.

 

 

2 Meter’s wireless communication failure

 

Suggestion: Please connect RS485 interface on the meter and USB convert to 485 serial port to read the parameters, and
confirm whether the parameters are the same as the upper terminal wireless configuration (channel and spread spectrum
factor). If different, please modify the meter’s wireless parameters and retest the master terminal after the same, and if
the same, it may be the meter and master terminal are in a relative long distance. It is too far to communicate or the scene
is seriously disturbed. We can try to use the external antenna at the same time, or consider the newly added wireless
master terminals, and then test it.

Contact Supplier

Mr. Tim Overseas sales engin Chat Now
Telephone
86-1870-6168051
Mobile
86-18761599716
Fax
86-1870-86179975
Skype
86 18761599716
Address
Jiangyin Wuxi,Jiangsu
Whatsapp
86 18761599716

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Hi~