Acrel DTSD1352-C approved 3 phase din rail KWH energy meter with RS485 Modbus 80A
Acrel DTSD1352-C approved 3 phase din rail KWH energy meter with RS485 Modbus 80A
Acrel DTSD1352-C approved 3 phase din rail KWH energy meter with RS485 Modbus 80A
Acrel DTSD1352-C approved 3 phase din rail KWH energy meter with RS485 Modbus 80A
Acrel DTSD1352-C approved 3 phase din rail KWH energy meter with RS485 Modbus 80A
Acrel DTSD1352-C approved 3 phase din rail KWH energy meter with RS485 Modbus 80A
Acrel DTSD1352-C approved 3 phase din rail KWH energy meter with RS485 Modbus 80A

Acrel DTSD1352-C approved 3 phase din rail KWH energy meter with RS485 Modbus 80A

USD $76.3 - $76.3 /Piece

Min.Order:1 Piece

Supply Ability:
1000 Piece / Pieces per Month
Payment Terms:
T/T Credit Card

Quick Details View All >

Brand Name:
Acrel
Place of Origin:
China
Model Number:
DTSD1352-C
Phase:
Three Phase
Output Voltage:
380V
Operating Temperature:
-25℃~55℃

Jiangsu Acrel Electrical Manufacturing CO.,LTD

Business license
Business Type: Manufacturer
Wuxi Jiangsu China
Main Products: power sensor ,programmable power meter ,DC power analyzer ,Data center monitor device ,Din rail energy meter ,Isolated power supply ,wireless temperature sensor ,IOT energy meter ,split core current transformer

Product Details

Outline and size
Instrument type
length
width
height
DTSD1352
88
126
70
Functions

Measurement

The meter can measure all electrical parameters such as voltage, current, active power, reactive power, apparent power, power factor, frequency, 31st harmonic and total harmonic. The value format of voltage, current, frequency and power are listed as below. Example: U = 220.1V,f = 49.98Hz, I = 1.99A,P = 0.439kW

Calculating

The meter can calculate the current active energy, forward active energy, reversing active energy, forward reactive energy and reversing reactive energy.

Timing

The meter has 2 time lists, and can be divided into 4 time zones per year. Each time list can be divided into 8 time periods and 4 tariff (F1、F2、F3、F4). The main purpose of multi-tariff is promote the energy efficiency and economic benefits.

History data statistics

The meter can record last 48 months or last 90 days history energy in eac

Switching input and output

The switch input adapts the method of on-off signal input and powered by outer power supply. It can be gotten by meter when there is a change of on or off via a switching input module. The parameter of switching input can not only get and show the state of local switching information but also achieve the communication via RS485, which called “remote information” function.

Temperature measurement

The meter support three path of outlay NTC temperature measurement, the range of temperature is -40℃~99℃.

Demand

Demand:The average power in the demand cycle. Maximum demand:The maximum value of demand in a period of time. Demand cycle:The time period between two same average value of demand. The default demand cycle is 15 minutes, slip time is 1 minute. The meter can measure 4 kinds of maximum demand: forward active, reversing active, inductance performance reactive, capacitance performance reactive maximum demand and the occur time.

Contact Supplier

Mr. Tim Overseas sales engin Chat Now
Telephone
86-1870-6168051
Mobile
86-18761599716
Fax
86-1870-86179975
Skype
86 18761599716
Address
Jiangyin Wuxi,Jiangsu
Whatsapp
86 18761599716

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Hi~