Acrel ADW300 three phase power meter
Acrel ADW300 three phase power meter
Acrel ADW300 three phase power meter
Acrel ADW300 three phase power meter
Acrel ADW300 three phase power meter

Acrel ADW300 three phase power meter

USD $73 - $73 /Set

Min.Order:1 Set

Supply Ability:
1000 Set / Sets per Month
Payment Terms:
T/T Credit Card

Quick Details View All >

Brand Name:
Acrel
Place of Origin:
China
Model Number:
ADW300
Phase:
Three Phase
Output Voltage:
380V
Operating Temperature:
-20℃~+55℃

Jiangsu Acrel Electrical Manufacturing CO.,LTD

Business license
Business Type: Manufacturer
Wuxi Jiangsu China
Main Products: power sensor ,programmable power meter ,DC power analyzer ,Data center monitor device ,Din rail energy meter ,Isolated power supply ,wireless temperature sensor ,IOT energy meter ,split core current transformer

Product Details

 

Product Description

ADW300 wireless meter is mainly used to measure three-phase active power in low-voltage network. It has the functions of RS485 communication and 470MHZ wireless communication. It is convenient for users to monitor, collect and manage electricity. It can be flexibly installed in the distribution box to realize the measurement, statistics and analysis of individual electric energy in different regions and loads.

 

Naming rules for ADW300 Wireless Metering Instruments  


Functional Characteristics of ADW300 Wireless Metering Instrument

Function

Functional description

Display mode

LCD (Field form)

 

Electric energy

metering

Active power metering (positive and reverse); four quadrant reactive power

Electricity measurement

Voltage, current, power factor, frequency, active power, reactive power, apparent power  

 

Harmonic function

Total harmonic content and fractional harmonic content (2-31 times)

Pulse output

Active Power Pulse Output

Three-phase unbalance

Voltage and current unbalance

Temperature measurement function

A, B, C, N four-way temperature measurement (optional T)

DI /DO

4DI/2DO(Selection of K)

Residual electricity

1-way Residual Electricity Measurement

LED instruction

Pulse and other indication

External CT

External open type CT(Selection of W)

Communication

Infrared Communication

 

RS485 Interface (Optional C)

470MHZ Wireless Transmission (Optional LR)

GPRS Wireless Communication (Optional 2G)

NB-IOT Wireless Communication (Selected NB) 

 

Electrical performance

 

 

Voltage input

Rated voltage

3×220/380V,3×380V,3×57.7/100V,3×100V

Reference frequency

50Hz

Power consumption

<10VA or 2W(A),<0.5VA(B,C)

 

Current input

Input current

3×1(6)A ,3×1.5(6)A(ADW300W)

Start current

4‰Ib(1class)

Power consumption

<2VA

 

Measurement performance

Standard

GB/T17215.321-2008,GB/T17215.322-2008

Active energy accuracy

 

0.5S class

Temperature Accuracy

±2℃

pulse

pulse width

80±20ms

Impulse constant

6400imp/kWh

 

 

Communication

 

wireless

Transmission on 470MHz and maximum distance in open space is 1km

Infrared communication

The constant baud rate is 1200

Interface

RS485(A,B)

Connection mode

Shielded twisted pair conductors

Protocol

MODBUS-RTU,DL/T 645-07

Working  environment conditions

Temperature range

Operating temperature

-25℃~55℃

Storage temperature

-40℃~70℃

Humidity

≤95%(No condensation)

Altitude

<2000m

Outline dimensions and installation instructions

Wiring instructions

ADW300 and ADW300W can be connected by three-phase four-wire through current transformer, three-phase three-wire through current transformer, three-phase four-wire through voltage transformer and current transformer and three-phase three-wire through current transformer and voltage transformer.

 

ADW300 Wiring instructions

Main Functional Characteristics

It can measure all power parameters including voltage U, current I, active power P, reactive power Q, apparent power S, power factor PF, phase angle of voltage and current Φ, voltage unbalance, current unbalance, frequency F, 2-31st fractional harmonics, odd and even total harmonics and total harmonics. Voltage U reserved 1 decimal, frequency F reserved 2 decimal, current I reserved 3 decimal, power P reserved 4 decimal, phase angle Φ reserved 2 decimal, unbalance  reserved 2 decimal.

Supporting 4-channel temperature measurement and residual current monitoring

Communication protocol

The instrument adopts MODBUS-RTU protocol or DL/645 protocol. For specific protocol formats, please refer to the relevant protocol standards.

Company Information


Acrel ADW300 three phase power meter

 

Packaging & Shipping

 Acrel ADW300 three phase power meter

 

Our Services

 Acrel ADW300 three phase power meter

 

FAQ

Common errors check and solve

 

1 The meter do not light after powered, or one path of voltage indicator do not light.

 

Suggestion: Please turn the screw to ensure that the meter needle has been punctured and contacted with the cable inner
conductor cable.

 

 

2 Meter’s wireless communication failure

 

Suggestion: Please connect RS485 interface on the meter and USB convert to 485 serial port to read the parameters, and
confirm whether the parameters are the same as the upper terminal wireless configuration (channel and spread spectrum
factor). If different, please modify the meter’s wireless parameters and retest the master terminal after the same, and if
the same, it may be the meter and master terminal are in a relative long distance. It is too far to communicate or the scene
is seriously disturbed. We can try to use the external antenna at the same time, or consider the newly added wireless
master terminals, and then test it.

Contact Supplier

Mr. Tim Overseas sales engin Chat Now
Telephone
86-1870-6168051
Mobile
86-18761599716
Fax
86-1870-86179975
Skype
86 18761599716
Address
Jiangyin Wuxi,Jiangsu
Whatsapp
86 18761599716

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Hi~