The guide-rail harmonic meter with external roche coil and open type mutual inductor is suitable for energy saving renovation projects in high energy consumption industries such as smelting,steel,electric welding,semiconductor,etc.And also for power monitoring of distributed photovoltaic grid-connected cabinet,power demand side management and other applications.The utility model has the advantages of no need to remove primary bus,simple and convenient wiring,safe construction,saving transformation cost and improving efficiency for users.It integrates the measurement of all power parameters(such as current,voltage,active power,reactive power,apparent power,frequency,power factor,etc.),multi-rate electric energy measurement,four-quadrant electric energy measurement,harmonic analysis and electric energy monitoring and assessment management.At the same time, it has a variety of peripheral interface for user to choose:with RS485 communication interface,modbus-rtu protocol can meet the needs of communication network management;The function of “remote signal” and “remote control” of circuit breaker switch can be realized with switch quantity input and relay output.LCD display interface is adoped to realize parameter setting and control through panel keys,which is very suitable for real-time power monitoring system.
2.Size of product
3.Product function
Note:1,“.”is standard allocation function,“.”is matching function,Above instrument stanfard
1 channel RS485 communication;
2,Terminal connection mode corresponding to A1/B1/C1 and so on in selection function;
3,Pulse output and relay output can not be selected at the same time;
4,When you select an event loggong feature,you must configure the DI or DO feature.
4.Technical parameter
5.Installation
5.1 Shape and installing size (unit:mm)
5.2 Size of open type transformer(unit:mm)
5.3 installation
Instrument installation method:DIN 35mm standard guide rail installation
Installation method of open and close type mutual induction
5.4Method of connection
(Note:in case of any inconsistency with the wiring diagram on the meter housing,the wiring diagram on the meter housing shall prevail) According to different design requirements,it is recommended to add fuses in the power supply and voltage input terminals to meet the safety requirements of relevant electrical codes
When three-phase three-wire connection is made,no.2 terminal and no.4 terminal shall be externally connected together
The fuse in the wiring diagram is recommended 0.5A or 3A.
When the instrument is installed on site,it must correspond to the supporing open and closed transformer or roche coil one by one,otherwise the measurement accuracy will be affected,and the connection between the two must be reliable.