Lower power consumption fresh air unit 6000 m3/h liquid desiccant air conditioning

Lower power consumption fresh air unit 6000 m3/h liquid desiccant air conditioning

USD $1,000 - $100,000 /Unit

Min.Order:1 Unit

Supply Ability:
200 Unit / Units per Month
Port:
Fuzhou
Payment Terms:
T/T Credit Card

Quick Details View All >

Brand Name:
Aolan
Place of Origin:
Fujian, China
Certification:
CE
Type:
Evaporative Air Cooler
After-sales Service Provided:
No overseas service provided
Condition:
New

Hodream Environment Equipment Co., Ltd.

Business Type: Manufacturer
Main Products: Industrial dehumidifier , , ,

Product Details

 

Product Description

Lower power consumption fresh air unit 6000 m3/h liquid desiccant air conditioning  

Introduction

Liquid desiccant air conditioning with purified air function can be widely applied in air conditioning system which allow heat recovery, such as fresh air treatment for office, R&D building, transportation hubs, exhibition centre, hotels, apartment, hospital, and factories, ect; especially suitable for independent temperature and humidity control air conditioning system combined with other dry-table and equipment.

Application

Suitable for indoor ventilation, and rate≥70%
Application environment temperature -5~40
 Working Principle

 Lower power consumption fresh air unit 6000 m3/h liquid desiccant air conditioning

  

Specification

Model (Txx-xx)

03

04

05

06

08

10

12

15

20

Power Source

3PH-380V-50Hz

Fresh Air Rate

m3/h

3000

4000

5000

6000

8000

10000

12000

15000

20000

Cooling Capacity

kW

65

85

108

128

172

215

255

325

430

Dehumidification

kg/h

65

85

108

128

172

215

255

325

430

Heating

kW

40

55

70

85

110

140

170

210

280

Moisture

kg/h

20

25

30

40

50

65

80

100

130

Power

kW

13.6

17.5

23.2

27.2

36.9

45.8

54.0

67.8

90.2

Noise

dB(A)

61

61

62

62

63

63

63

63

64

Compressor type

Full Closed Scroll Compressor

Throttle type

The Balance Type Thermal Expansion Valve

Refrigerant type

R22/R407C

Filtration grade

Primary (G4)

Supply/Exhaust air type

The Outer Rotor Centrifugal Fan

over-bottom pressure

Pa

150

150

180

180

210

240

250

300

350

Weight

kg

2050

2200

2650

3080

3580

4350

5250

6010

6820

  

Notes:  1.Nominal cooling and dehumidification working conditions: fresh air dry bulb temperature 36℃, relative humidity 60%,; returned air dry bulb temperature 26℃, relative humidity 60%; supply air dry bulb temperature 18, wet bulb temperature 13.3.   2. Nominal heating and humidification working conditions: fresh air dry bulb temperature -5℃, relative humidity 50%,;returned air dry bulb temperature 20℃, relative humidity 50%; supply air dry bulb temperature 18, wet bulb temperature 13.7 3. The above section and setting are only for reference. Please choose and adjust based on actual project requirement, or provided y customer.

 

Dimension Drawing

 

1,AHLD-Txx-03,04,05,06,08,10,12

Lower power consumption fresh air unit 6000 m3/h liquid desiccant air conditioning

 

2,AHLD-Txx-15,20

Lower power consumption fresh air unit 6000 m3/h liquid desiccant air conditioning

 

 

 

Model (Txx-xx)

03

04

05

06

08

10

12

15

20

          L

mm

3000

3000

3100

3100

3200

3200

3400

3200

3200

W

mm

1400

1400

1850

1850

2250

2250

2250

4800

4800

H

mm

2200

2250

2400

2400

2400

2550

2800

2400

2550

Supply Air Outlet

A

mm

310

363

406

406

467

467

467

496

496

B

mm

275

275

338

338

420

420

420

445

445

Amount

1

2

Exhaust Air Outlet

C

mm

310

363

406

406

467

467

467

496

496

D

mm

275

275

338

338

420

420

420

445

445

Amount

1

2

Fresh Air Outlet

E

mm

700

700

900

900

1300

1300

1300

1300

1300

F

mm

550

650

550

700

700

800

900

700

800

Amount

1

2

Return Air Outlet

J

mm

1100

1100

1500

1500

1900

1900

1500

1900

1900

K

mm

350

450

450

500

500

550

650

500

550

Amount

1

2

  Note:As our products are improved continuously, specifications in the tables are subject to change without notice.

 

 

Company Information

 Lower power consumption fresh air unit 6000 m3/h liquid desiccant air conditioningLower power consumption fresh air unit 6000 m3/h liquid desiccant air conditioningLower power consumption fresh air unit 6000 m3/h liquid desiccant air conditioningLower power consumption fresh air unit 6000 m3/h liquid desiccant air conditioningLower power consumption fresh air unit 6000 m3/h liquid desiccant air conditioningLower power consumption fresh air unit 6000 m3/h liquid desiccant air conditioningLower power consumption fresh air unit 6000 m3/h liquid desiccant air conditioningLower power consumption fresh air unit 6000 m3/h liquid desiccant air conditioning

 

 

  

Contact Supplier

Mobile
12592974061

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Machinery > Refrigeration & Heat Exchange Equipment > Industrial Air Conditioners
Categories
Hi~