Integrated Filter Material  Filtration Performance Testing System

Integrated Filter Material Filtration Performance Testing System

Negotiable /Set

Min.Order:1 Set

Supply Ability:
200 Set / Sets per Month
Port:
Shanghai, China
Payment Terms:
T/T
Delivery Detail:
30 days

Quick Details View All >

Brand Name:
QINSUN
Place of Origin:
China

Qinsun Instruments Co., LTD

Business Type: Manufacturer
Shanghai China
Main Products: thermal resistance wet resistance meter ,moisture management tester ,air permeability tester , rubbing color fastness tester

Product Details


The new high efficiency filter material filtration performance tester uses the current international mainstream particle counting method, the high efficient large flow laser particle counter to test the basic filtration performance parameters of filter material, such as filtration efficiency, particulate transmittance, pressure drop curve, residual pressure drop, filtration/cleaning cycle, etc. The alternative patented horizontal and vertical structure achieves a comprehensive test for filtration material, compatible with more testing requirements. Combined with the life span testing module, the testing system can make cyclic test for filtration material so as to obtain the dynamic filtration performance of the filtration material as well as the information on efficient filtering life span.


The unique alternative vertical dirty gas pipe can simulate the actual use process of filtration material. It is applicable to test the basic static filtration efficiency and to provide actual simulation test for research and development, achieving  the verification of versatile function performance of filtration material. The bottom is equipped with a dust collector, to avoid the dust re-dispersion to the air upstream  of the tested filtration material, which lead s to the uncertainty of the dust concentration and invalidity of the measurement (especially important parameter: residual pressure drop value). The design of the instrument achieves long term operation with zero error, and there is no need of frequent full suspension of the measurement for cleaning the dust deposition.


Application
Applicable to multiple areas Professional and reliable testing device, great repeatability, ensures more accurate and reliable test results.


Test dust pipe
1.Horizontal dust pipe and filter material fixture.
2.Vertical dust pipe and filter material fixture.
3.Lift and fall dust generation device.
4.Analytic filter for testing dust concentration
5.Pressure detection system


The new comprehensive filter materials filtration performance testing system evaluates the filtration performance of filter media through the comprehensive performance test of the resistance and efficiency in the process of filter cleaning, aging and stabilizing. It’s applicable to the quality control for filter materials industrial production enterprises, product performance verification for filter materials R & D enterprises, filter materials filtration performance testing services for third-party testing agencies and the market-oriented product quality supervision for environmental protection agencies.


Technical Parameters

Aerosol generator
Dust generation amount8 g-550 g/h (reference dust: SAE,Fine A2 Dust)
Pural NF, Pural SB, ISO A2 fine powder,ISO A4 coarse powder, lime, silica, plaster ash, different types of TiO2 or other non sticky powder.
Wind speed range5-10 m³/h±1%
Dust container volume3.2L
Outlet dust concentration0.8-100 g/m3, accuracy<±7. the deviation of dust concentration of the same specimen under 3 consecutive tests is within 5%.
Dust generator weighing mechanism30kg load units, accuracy of 1g
High capacity consecutive dust supplying deviceCooperate with the load unit. Automatically feed dust without checking the dust feeding quite frequently.
Dust generator lift and fall deviceMeet the use requirements of horizontal and vertical air pipe.
Transparent horizontal air pipe
Air pipe temperature transducerTemperature range: 0-100℃, accuracy of ±0.3℃(high temperature optional)
DiameterΦ160mm
Air velocity0-6m3/h±1%
Pressure transducer0-1100mbar±0.5%
Vertical air pipe
Air pipe temperature transducerTemperature range: 0-100℃, accuracy of ±0.3℃(high temperature optional)
Pressure transducer0-1100mbar±0.5%
Air velocity0-6m3/h±1%
Optical condensation monitorMeasure and monitor the test dust concentration and distribution in the air pipe
Luminance meterThe consolidation period is less than 10 seconds. Laser energy is 1mW. Wavelength is 650nm±10nm
Standard dust concentration monitoring range(0~10)g/m3


Standards
EN 779 Particulate air filters for general ventilation - Determination of the filtration performances.
VDI 3926 Standard test for the evaluation of cleanable filter media


Contact Supplier

Mr. Qinsun Chat Now
Telephone
86-21-67800179
Mobile
86-17740808215
Fax
86-21-67800179-810
Address
Songjiang Shanghai

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Measuring & Analysing Instrument Design Services
Categories
Hi~