Medical Face Mask Synthetic Blood Penetration Resistance Tester

Medical Face Mask Synthetic Blood Penetration Resistance Tester

Negotiable /Set

Min.Order:1 Set

Supply Ability:
200 Set / Sets per Month
Port:
Shanghai, China
Payment Terms:
T/T
Delivery Detail:
30 days

Quick Details View All >

Brand Name:
QINSUN
Place of Origin:
China

Qinsun Instruments Co., LTD

Business Type: Manufacturer
Shanghai China
Main Products: thermal resistance wet resistance meter ,moisture management tester ,air permeability tester , rubbing color fastness tester

Product Details

Medical masks synthetic blood penetration tester is used to determine the resistance of medical protective masks to penetration by synthetic blood at different test pressures,and can also be used to determine the resistance to blood penetration of other coating materials.


Application


The device is used for anti-synthetic blood penetration of medical surgical masks, and mainly used in the field of medical protection products. It can also be used for other textile coating material determination.


GB 19083-2010 Technical requirements of medical face masks - Anti-penetration property of 5.5 synthetic blood.
YY/T 0691-2008 Clothing for protection against infectious agents-Medical face masks - Test method for resistance against penetration by synthetic blood (fixed volume, horizontally projected)  
YY 0469-2011 Technical requirements of medical face masks– Blood penetration test apparatus.
ISO 226092004 Clothing for protection against infectious agents - Medical face masks - Test method for resistance against penetration by synthetic blood (fixed volume, horizontally projected)  
ASTM F1862-07Standard Test Method for Resistance of Medical Face Masks to Penetration by Synthetic Blood (Horizontal Projection of Fixed Volume at a Know Velocity)


ItemsParameters
Injection distance300mm~305mm, adjustable
Nozzle diameter0.84mm
Jet velocity450cm/s,550cm/s,635cm/s


Standards

1.The protruding sample fixture can simulate the actual use condition of the mask. Reserve the test target area without destroying the sample, and   distribute synthetic blood in the sample target area.
2.A special jet device with constant pressure can spray a certain volume of synthetic blood in a controlled time.
3.It can fully simulate the corresponding injection rate to test under the average blood pressure of the human body at 10.6kPa, 16kPa, 21.3kPa.
4.The fixed target plate can block the high pressure part of the injected liquid flow to allow the steady flow to be sprayed to the sample, increasing the accuracy and repeatability of liquid spraying speed.


Contact Supplier

Mr. Qinsun Chat Now
Telephone
86-21-67800179
Mobile
86-17740808215
Fax
86-21-67800179-810
Address
Songjiang Shanghai

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Measuring & Analysing Instrument Design Services
Categories
Hi~