SS304 Steam Generator Horizontal Autoclave For Laboratory Research Institutes
Negotiable /Set
Min.Order:1 Set
Infection Control Autoclave Steam Sterilizer , Hospital Steam Sterilizers For CSSD Department
Hinge Door Horizontal Autoclave , Temperature Sensors Laboratory Steam Sterilizer
Vertical Sliding Door Horizontal Autoclave With For Medical Waste Sterilization
Touch Screen PLC Control Systems Steam Sterilizer Autoclave Horizontal
Professional Pasteurized Steam Autoclave Sterilizer Machine For Spice / Herb
120 Liters Horizontal Autoclave With Full SUS304 Built - in Steam Generator
SS304 Steam Generator Horizontal Autoclave For Laboratory Research Institutes
Key Features:
• Chamber, steam jacket, door and steam generator made of 304 stainless steel
• Pneumatically controlled door opening with safety system
• Steam driven one piece chamber gasket made of silicon
• High capacity, low noise water ring vacuum pump for vacuum function
• High quality valves, sensors and transmitters for a problem free and safe operation
• Pneumatic valves in the steam lines
• PLC control system with 5.7\" colorful touch screen
• Wide screen allows monitoring all related information regarding sterilization cycle
• 5 preset programs, 30 custom made programs
• Two test programs: Bowie & Dick and vacuum leakage
• Memory for last 25 cycles
• Independent control system besides the main control system to record the data related to every cycle
• Service menu to detect the problem in case of a failure
• Thermal printer offered as standard
• Single and double door versions
Description:
We regularly outfit our BSL-3 pass-through autoclaves with Effluent Retention systems. These are required by law in some biosafety contexts, but also valuable in non-BSL settings where waste loads are frequently processed. This system includes placing a 0.22 micron filter in the vent outlet to prevent organisms—including viruses—from escaping the autoclave in vapor. All condensate is then collected and held in the hottest part of the chamber, so that it is sterilized during the cycle.Main Parameters:
Model |
Chamber Size |
Overall Size |
Steam |
Water |
Power |
W*H*D mm |
W*H*D mm |
Kg/cycle |
Kg/cycle |
KVA |
|
MDL-0.24 |
600*600*670 |
1500*1800*1010 |
20 |
230 |
2 |
MDL-0.36 |
600*600*1000 |
1500*1800*1340 |
25 |
240 |
2 |
MDL-0.6 |
610*910*1170 |
1500*1900*1510 |
30 |
260 |
3 |
Safety Features:
Safety Is Our Top Priority
Safety of personnel is an important issue. Our autoclaves include numerous safety
features / systems to ensure a safe work environment.
Door Safety
The laboratory autoclaves are designed with a number of independent mechanical and digital
safety features:
In case of failure the clean door remains closed in order to protect the clean area from contamination. A safety device prevents the operator from opening the door when the chamber is pressurized Steam will not enter the chamber when the door is open. A cycle cannot start if the door is open or not properly locked. The door cannot unlock until liquid temperature reaches the predetermined end temperature. The door cannot unlock until chamber pressure reaches room pressure. An air inflated door gasket creates a hermetic seal between the door and chamber. Double Door Safety - interlocks prevent both doors from being opened simultaneously.Safety About All:
The application field of our laboratory sterilizers meets all safety categories (bio-safety level) from BSL1 to BSL4. The sterilization processes, sterilizer capacity and the design
match the corresponding sterilization goods. Our long-standing proven sterilization processes and programs ensure reproducible processes and are
GLP-compliant.