Cast Aluminum Goyen Pulse Jet Valve Diaphragm Dust Collector Valves
USD $65 - $96 /Set
Min.Order:1 Set
Ningbo Nijia Electronics Technology Company
Aluminum Dust Collector Pulse Valves / Goyen Dust Collector Valves
24V DC Goyen Pulse Jet Valve DIN43650A with Copper Shading Coil
Goyen Aluminum Screw Diaphragm Operated Valve AC 230Volt CA45DD
Heat Resistant 14.5 220V AC Solenoid Coil for K23JD-20 K23JD-25 Valve
Goyen Flanged Inlet Dust Collector Valve CAC45FS CAC45FS010-300 1-1/2 \"
Goyen Cast Aluminum diaphragm valve CA62T 010-300 2 1/2 \" AC230V 50/60Hz pulse jet valve
Suitable for
Dust collector applications, in particular for reverse pulse jet filter cleaning including bag filters, cartridge filters, envelope filters, ceramic filters, and sintered metal fibre filters.
Constuction Material:
Body | Aluminium (diecast) |
Ferrule | 304 SS |
Armature | 430FR SS |
Seals | Nitrile or Viton (reinforced) |
Spring | 304 SS |
Screws | 302 SS |
Clip | Mild steel (plated) |
Locknut | Mild steel zinc passivated |
Voltage | DC: 24V, AC: 24V,48V,110V,230V |
Working Temperature | - 20 to + 85 ℃ |
Protection Class | IP65 |
Coil Insulation Class | F |
Working Pressure | 0.35-0.85Mpa |
Diaphragm Seat | PA-6 or Viton coated mild steel or High Density PE |
Sealing & disc | CR (chloroprene) |
Diaphragm | NBR(nitrile/buna-n) or Viton |
Shading coil | Copper |
Connector | DIN43650A |
Weight:
Size | Integral Pilot | Remote Pilot |
(CA) Kg (lbs) | (RCA) Kg (lbs) | |
20 | 0.60 ( 1.31 ) | 0.38 ( 0.83 ) |
25 | 0.73 ( 1.61 ) | 0.51 ( 1.13 ) |
35 | 1.04 ( 2.28 ) | 0.83 ( 1.83 ) |
45 | 1.50 ( 3.30 ) | 1.28 ( 2.83 ) |
50 | 2.89 ( 6.38 ) | 2.68 ( 5.92 ) |
62 | 3.31 ( 7.30 ) | 3.09 ( 6.82 ) |
76 | 4.77 ( 10.52 ) | 4.56 ( 10.04 ) |
INSTAllATION:
1 | The valves can be mounted in any position without affecting operation |
2 | Threaded pipe connection is: G = G (ISO 228/1) or compression fittings |
3 | When connecting piping or tubing to the G1/8 connection in the valve bonnet, the remote pilot valve should be mounted as close as possible to the main pulse valve. Connection tubing lengths of 3 meter or less have little effect on the pulse response. Installations with over 3 meter of tubing must be tested under actual operating conditions. Tubing with Ø 6 mm O.D. is recommended for all installations |
4 | Ensure supply air is clean and dry. |
5 | Mount valves to inlet pipes and blowtube to valves, ensuring no excess thread sealant can enter the valve itself. |
6 | Apply moderate pressure to system and check for installation leaks. |
7 | For compression fitting types tightness is achieved by the compressed gasket on the blow tube |
8 | Other pipe threads are available on request |
9 | Installation/maintenance instructions are included with each valve |
10 | Make electrical connections to solenoid or connect RCA pilot port to pilot valve (RCA valves only). |
Maintenance:
Before conducting any maintenance activity on the system ensure that components are fully isolated from
pressure and power supplies. Pressure and power should not be reapplied until the valve has been fully assembled.
Diaphragm and pilot inspection should be conducted annually
DIMENSIONS (mm) :
Product show:
Fitted Repair kits code: Diaphragm K5000 / K5004(Vition)