High Performance DIN43650A Goyen Diaphragm Valve CA50MM 010-300 2 \" AC230V
USD $65 - $96 /Piece
Min.Order:1 Piece
Ningbo Nijia Electronics Technology Company
IP65 Waterproof Pulse Diaphragm Valve DC 24V AC 24V/48V/110V/230V
Die Cast Aluminum Goyen Pulse Jet Valve Coil Insulation Class F 0.35Mpa-0.85Mpa
Goyen Dust Collector Pulse Valve High Performance Diaphragm Valve
ASCO K0950 Solenoid Armature Plunger for SCG353A047 SCG353A050 SCG353A060
Aluminium SS 3/4 \" AC230V Right Angle Pulse Jet Valve CA20T 010-300
High Pressure Pneumatic Solenoid Coil 10.2 for 4V Magnetic Valve Series
Goyen DIN43650A Aluminum diaphragm valve CA50MM 010-300 2 \" AC230V pulse jet valve
Operation :
Recommended on time range: 50-500ms
Recommended time between pulses: 1 minute or greater
Suitable for
Dust collector applications, in particular for reverse pulse jet filter cleaning including bag filters, cartridge filters, envelope filters, ceramic filters, and sintered metal fibre filters.
Constuction Material:
Body | Aluminium (diecast) |
Ferrule | 304 SS |
Armature | 430FR SS |
Seals | Nitrile or Viton (reinforced) |
Spring | 304 SS |
Screws | 302 SS |
Clip | Mild steel (plated) |
Locknut | Mild steel zinc passivated |
Voltage | DC: 24V, AC: 24V,48V,110V,230V |
Working Temperature | - 20 to + 85 ℃ |
Protection Class | IP65 |
Coil Insulation Class | F |
Working Pressure | 0.35-0.85Mpa |
Diaphragm Seat | PA-6 or Viton coated mild steel or High Density PE |
Sealing & disc | CR (chloroprene) |
Diaphragm | NBR(nitrile/buna-n) or Viton |
Shading coil | Copper |
Connector | DIN43650A |
Description
High performance diaphragm valve with threaded ports. Available with integral pilot or as remotely piloted valve. Outlet at 90° to inlet.
INSTAllATION:
1 | When connecting piping or tubing to the G1/8 connection in the valve bonnet, the remote pilot valve should be mounted as close as possible to the main pulse valve. Connection tubing lengths of 3 meter or less have little effect on the pulse response. Installations with over 3 meter of tubing must be tested under actual operating conditions. Tubing with Ø 6 mm O.D. is recommended for all installations |
2 | Ensure supply air is clean and dry. |
3 | Mount valves to inlet pipes and blowtube to valves, ensuring no excess thread sealant can enter the valve itself. |
4 | Apply moderate pressure to system and check for installation leaks. |
5 | For compression fitting types tightness is achieved by the compressed gasket on the blow tube |
6 | Other pipe threads are available on request |
7 | Installation/maintenance instructions are included with each valve |
8 | Make electrical connections to solenoid or connect RCA pilot port to pilot valve (RCA valves only). |
9 | Fully pressurise system. |
10 | Test fire and listen for proper actuation and crisp pulse noise. |
Maintenance:
Before conducting any maintenance activity on the system ensure that components are fully isolated from
pressure and power supplies. Pressure and power should not be reapplied until the valve has been fully assembled.
Diaphragm and pilot inspection should be conducted annually
Product show:
Fitted Repair kits code: Diaphragm K5000 / K5004(Vition)