IP65 Waterproof Pulse Diaphragm Valve DC 24V AC 24V/48V/110V/230V
USD $65 - $96 /Twenty-Foot Container
Min.Order:1 Twenty-Foot Container
Ningbo Nijia Electronics Technology Company
Die Cast Aluminum Goyen Pulse Jet Valve Coil Insulation Class F 0.35Mpa-0.85Mpa
Goyen Dust Collector Pulse Valve High Performance Diaphragm Valve
ASCO K0950 Solenoid Armature Plunger for SCG353A047 SCG353A050 SCG353A060
Aluminium SS 3/4 \" AC230V Right Angle Pulse Jet Valve CA20T 010-300
High Pressure Pneumatic Solenoid Coil 10.2 for 4V Magnetic Valve Series
Goyen Dust Collector Valves Diaphragm Pulse Jet Valve Outlet At 90 To Inlet
Goyen Cast Aluminum diaphragm valve CA50T 010-300 2 \" AC230V pulse jet valve
Suitable for
Dust collector applications, in particular for reverse pulse jet filter cleaning including bag filters, cartridge filters, envelope filters, ceramic filters, and sintered metal fibre filters.
Constuction Material:
Body | Aluminium (diecast) |
Ferrule | 304 SS |
Armature | 430FR SS |
Seals | Nitrile or Viton (reinforced) |
Spring | 304 SS |
Screws | 302 SS |
Clip | Mild steel (plated) |
Locknut | Mild steel zinc passivated |
Voltage | DC: 24V, AC: 24V,48V,110V,230V |
Working Temperature | - 20 to + 85 ℃ |
Protection Class | IP65 |
Coil Insulation Class | F |
Working Pressure | 0.35-0.85Mpa |
Diaphragm Seat | PA-6 or Viton coated mild steel or High Density PE |
Sealing & disc | CR (chloroprene) |
Diaphragm | NBR(nitrile/buna-n) or Viton |
Shading coil | Copper |
Connector | DIN43650A |
Description
High performance diaphragm valve with threaded ports. Available with integral pilot or as remotely piloted valve. Outlet at 90° to inlet.
Weight:
Size | Integral Pilot | Remote Pilot |
(CA) Kg (lbs) | (RCA) Kg (lbs) | |
20 | 0.60 ( 1.31 ) | 0.38 ( 0.83 ) |
25 | 0.73 ( 1.61 ) | 0.51 ( 1.13 ) |
35 | 1.04 ( 2.28 ) | 0.83 ( 1.83 ) |
45 | 1.50 ( 3.30 ) | 1.28 ( 2.83 ) |
50 | 2.89 ( 6.38 ) | 2.68 ( 5.92 ) |
62 | 3.31 ( 7.30 ) | 3.09 ( 6.82 ) |
76 | 4.77 ( 10.52 ) | 4.56 ( 10.04 ) |
INSTAllATION:
1 | Spare parts kit and replacement coils are available |
2 | Prepare supply and blowtube pipes to suit valve specification. Avoid installing valves underneath the tank. |
3 | Ensure tank and pipes are free from dirt, rust or other particulate. |
4 | Ensure supply air is clean and dry. |
5 | Mount valves to inlet pipes and blowtube to valves, ensuring no excess thread sealant can enter the valve itself. |
6 | Apply moderate pressure to system and check for installation leaks. |
7 | For compression fitting types tightness is achieved by the compressed gasket on the blow tube |
8 | Other pipe threads are available on request |
9 | Installation/maintenance instructions are included with each valve |
Maintenance:
Before conducting any maintenance activity on the system ensure that components are fully isolated from
pressure and power supplies. Pressure and power should not be reapplied until the valve has been fully assembled.
Diaphragm and pilot inspection should be conducted annually
DIMENSIONS (mm) :
Product show:
Fitted Repair kits code: Diaphragm K5000 / K5004(Vition)