DN15A Manual Reset Water Solenoid Valve Gas Emergency Shut Off Solenoid Valves

DN15A Manual Reset Water Solenoid Valve Gas Emergency Shut Off Solenoid Valves

Negotiable /Set

Min.Order:1 Set

Supply Ability:
0 Set / Sets per Month
Payment Terms:
T/T L/C D/P D/A
Delivery Detail:
7 days

Quick Details View All >

Brand Name:
GOGOATC
Place of Origin:
China
Model Number:
PMC

GOGO Automatic Company Ltd.

Business Type: Trading Company
Main Products:

Product Details

Delivery Time:5 working days after received your payment
Certification:CE

DN15A manual reset 1/2" Nickel-plated brass gas emergency shut off solenoid valves for home DC6-24V

Features:
This valve mainly be used in every kind of fuel gas pipeline being in danger (divulging, breakage) to give an alarm and quick closedown automatically, especially suitable for inflammable gas pipeline's safety and protection system. May match with each kind of alarm apparatus.
Specifications:
◆ Suited Air:Natural Gas,Liquefied Gas,Manufactured Gas and Non-corrosiveness Air
◆ Open Way:DC pulse driving,manual
◆Driving Voltage:DC9-12V (pulse)
◆ Driving Current:<1.5A (pulse)
◆ Valve Body: Brass Alloy/Aluminum
◆ Connection Type: G1/2〞(DN15A) G3/4〞(DN20A)
◆ Seals Material: NBR
◆ Open Time:less than 1second
◆ Max Pressure:500mbar
◆ Wire Length: No less than 0.4 meter

Specifications

Suitable gas types: town gas
Body: wrought aluminum alloy
Sealing meterial NBR rubber
Operation temperature <50°C
Working pressure: 0~50bar
Max pressure: 50bar
Connection: 1/8" , 1/4"
Turn on: manual
Driving Voltage: DC9-12V
Closing modes: current impulse or manual
Alose time: <1sec
Explosion proof of mark: Exmb IIT4
Lead wire: 0.4m
Model Pipe Orifice
Diameter(mm)
Closing modes Weight Body
material
Seal Work Pressure
PMC-15 1/2" 14 current impulse or manual 0.4kg aluminum alloy NBR 0-50bar
PMC-20 3/4" 16 0.5kg 0-50bar

Dimensions

Size A B C D
DN15A 60 100 87 27
DN20A 67 108 91 34

.

Introduction

The valve is a series of gas emergency shut off solenoid valves, specially designed as gas pipe breaker for emergency use . It can be connected with gas leaking detection sensor ,fire alarm circuit or other intelligent sensor modules so that on site or remote shut down on gas supply (manually or automatically) is possible , hence ensuring the safety on gas usage .the valve features an auto-close when strong vibration is detected .After close,manual operation is required to turn on the valve. This feature meets safety regulations in the event of an accident.

Working Principal

When the switch is pressed, the capacitor discharges and provides an electric current so that a coil can generate strong magnetic held to pull down the valve, achieving the closing within one second.

Operation instruction

1.There are two ways to close the valve:

(a)An electric impulse of 1 sec (DC 9V),or

(b)Press the red knob (must open the protective cover first ). After this operation, the valve remains closed.

Note: the protective cover must remain on position at all time.

2.When the valves is closed,manually pull the red knob up to turn it on .then the valve remains on.

Note:the valve may not to be pulled up if gas pressure on both sides(inlet and outlet) is not balanced. Take necessary action to ensure that they are balanced ,then pull the knob up again,force pulling it may result in damage to the valve.

3.The valve will close automatically when it detects strong vibrations. Should this feature fails, notify the contractor or manufacture for repair.

4.After closing ,careful inspection is required.Do exercise caution when the valve needs to be turned on again.
Installation Requirements
1. Only request contractor can install this valve.
2 .The valve must be installed after the indoor main valve.
3 .A valve should be installed in the gas flow direction marked on the valve body. The coil must not be placed in downward position A valve may be installed horizontally or vertically.
4. the valve control wires should be connected correctly. White indicates positive while black stands for negative. Mismatch lends to fatal consequences.
5. During pipe maintenance, such as pressurized pipe cleaning .the valve should removed to avoid damages to the valve sealing.
6.During pressure tests, the valve s

Contact Supplier

Mrs. Jen Qi sale Manager Chat Now
Telephone
86-574-88552150
Mobile
86-18958207546
Fax
86-574-88552150
Skype
bagadandan
Address
No.28,Nandu Road,Jiangkou Town Yantai,Shandong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Machinery > Packaging Machine > Packaging Material Making Machine > Belt Making Machines
Categories
Hi~