Organic Solvent Residue Tester
Negotiable /Piece
Min.Order:1 Piece
GC-7960 Organic Solvent Residue Tester applies to test of solventresidue on various printing films, laminated films, extrusion films and variousdrug-use films as well as sheets, meanwhile GC-7960 could test water amount inorganic solvent as well, it is one highly cost-effective tester and SYSTESTERlaunched GC-7960 specially for food & pharmaceutical industries, qualityinspection departments as well as research and development institutions.
Characteristics
1: Organic solvent residue test and solvent purity test combined inone.
2: Microcomputer controls, LCD displays.
3: PVC keyboard, easy to operate.
4: Dual CPUs design, excellent electromagnetic interferenceprotection.
5: Dual FID detectors, dual gas circuits system, self-diagnosisfunction.
6: Ignite automatically.
7: Constant and programming temperature control function.
8: Temperature control accuracy over 0.1 degrees celcius.
9: 8 grade temperature programming function.(Personal customizationavailable)
10: Temperature rising fast, highly efficient capillary column,zero-dead volume.
11: Bigger oven design.
12: Variable frequency cooling system, easy to do a nearest roomtemperature test.
13: Record parameters automatically even power’s down.
14: Over temperature protection function.
15: Carrier gas flow monitoring to protect TCD detector and ovencolumn.
16: Self-diagnosis function, trouble is easy to resolve.
17: Powerful chromatographic work station.
Technical indexes
1: Temperature control:
Oven: room temperature +8– 420°C, accuracy ±0.1°C (at 200°C)
Injector: room temperature+8 – 420°C, accuracy ±0.1°C (at 200°C)
Detector: room temperature+8 – 420°C, accuracy ±0.1°C (at 200°C)
2: Oven
Temperature control: room temperature +8 – 420°C, accuracy ±0.1°C(at 200°C)
Dimension: 280mm X 280mm X 250mm
Programmed temperature: 8 grades.(Personal customization available)
Programmed temperature rising rate: 1 – 50°C
Dwell time at one grade: 0 – 300min
3: FID detector
Detection limit: ≤8×10-12 g / s(Hexadecane/Isooctane)
Baseline noise: ≤0.02
Baseline drift: ≤0.15
Linearity: 106
Signal stabilization time: < 20min
Ignition: Auto.
Standards
YBB20162012、YBB20172012、YBB20182012、YBB20252012、YBB20262012、YBB20272012
Configuration
Standard configuration: Gas chromatograph, FID detector,professional column, GC workstation.
Optional: Headspace injection device, air generator, hydrogengenerator, nitrogen generator.
Remark: Gas source, analytical reagent, computer should be providedfor yourself.