Product Details
Instructions
Principle of the PM60A1 Patient Monitor is as follows: Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning & Recording Technology,the Patient Monitor can be used in measuring the pulse oxygen saturation and pulse rate through finger.The product is suitable for being used in family, hospital, oxygen bar, community healthcare, physical care in sports (It can be used before or after doing sports, and it is not recommended to use the device during the process of having sport) and etc.
Major Features
■Small in volume,light in weight and convenient in carrying
■Operation of the product is simple ,low power consumption
■SpO2 value display
■Pulse rate value display, bar graph display
■Pulse waveform display
■The display mode can be changed
■Changeable light-time
■A pulse rate sound indication
■With measured data overruns limits and low-voltage alarm function, the upper/down alarm range is adjustable
■With clock function
■Full screen touch operation
■Big capacity SD card case storage(almost 10000 cases)
■Battery capacity indication
■Connected with an external oximeter probe
■Trend Review Graph/Table:Resolution from 1s, 5s, 10s, 30s, 1min, and so on. Store latest 96 hours trend data.
■Alarm:Adjustable High and Low limits. Three level audible and visual alarm , latest 50 alarm information and waveform displays 8 seconds which 4 seconds are before a certain time when the alarm is turned on and 4 seconds are after appointed time when the alarm is turned on.
■Wave Review: Store lastest 24 hours waveform of the current real-time monitoring patient.
■Upload data: Data stored in SD card can be uploaded to computer and analyzed by software "SpO2 Assistant".
■Wireless communication function(PM60A1W)
Main performance
Display Mode: 3.5 inch TFT color display;
Screen Resolution: 320*240
SpO2 Measuring Range: 0%~100%, (the resolution is 1%).
Accuracy: 70%~100%: ±2% ,Below 70% unspecified.
PR Measuring Range: 30bpm~250bpm, (the resolution is 1bpm)
Accuracy: ±2bpm or ±2% (select larger)
Measurement Performance in Weak Filling Condition:
SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.
Power Consumption: less than 300mA
Voltage: DC 5.0V
Power Supply: Built-in recharge Li-Polymer
Battery working hour: 9 hours
Safety Type: Interior Battery, BF Type
Accessories
Sell in standard:
■A user manual
■A data line
■A power adapter (GTM41076-0605;CMS0105)
■A disk (PC software)
■An oximeter probe
Sell in addition:
■Other oximeter probe(Refer to probe application instruction for details and notice renewal)
Physical Identity
Dimension: 130(L)x73(W)x25(H)mm
Weight: About 172g(with battery)