CMS60D Pulse Oximeter  CE

CMS60D Pulse Oximeter CE

Negotiable /Pair

Min.Order:1 Pair

Supply Ability:
0 Pair / Pairs per Month
Payment Terms:
T/T L/C D/P D/A
Delivery Detail:
7 days

Quick Details View All >

Brand Name:
Contec
Place of Origin:
China
Model Number:
CMS60D

Contec Medical Systems Co., Ltd

Business Type: Trading Company
Main Products: Pulse oximeter , Fetal Monitor , Fetal Doppler , B-Ultrasound , ECG Machine , Patient Monitor , Stethoscope , ECG Series , Endoscope , EMG/EP PSG , Surgical Unit , Infusion Pump , Transcranial Doppler , Blood Pressure Monitor , Medical Image System , OEM.

Product Details

Major Features ◆Small in volume,light in weight and convenient in carrying ◆Operation of the product is simple ,low power consumption ◆Operation menu for the function setting ◆SpO2 value display ◆Pulse rate value display, bar graph display ◆Pulse waveform display ◆Screen brightness can be changed ◆A pulse rate sound indication ◆Review function ◆With measured data overruns limits and low-voltage alarm function, the upper/down alarm range is adjustable ◆Battery capacity indication) ◆Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage ,and with alarm function ◆With SpO2 value and pulse rate value of storage, the storage data can be uploaded to computers ◆Real-time data can be transmitted to computers ◆Connected with an external oximeter probe ◆Wireless communication function(CMS60DW) Main performance Display Mode: 1.8" Color OLED display Screen Resolution: 160*128 SpO2 Measuring Range: 0%~100%, (the resolution is 1%). Accuracy: 70%~100%: ±2% ,Below 70% unspecified. PR Measuring Range: 30bpm~250bpm, (the resolution is 1bpm) Accuracy: ±2bpm or ±2% (select larger) Measurement Performance in Weak Filling Condition: SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger). Resistance to Surrounding Light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%. Power Consumption: less than 100mA Voltage: DC 3.0V Power Supply: Alkaline battery(2AA) Battery Working Hour: Theoretical number is 44 hours. Safety Type: Interior Battery, BF Type Accessories Sell in standard: ◆A user manual ◆A data line ◆A disk (PC software) ◆An oximeter probe Sell in addition: ◆Other oximeter probe(Refer to probe application instruction for details and notice renewal) Physical Identity Dimension: 110(L) × 60(W) × 23(H) mm Weight: About 180g (with Alkaline battery(2AA)) Qualification CMS60D passed FDA and CE

Contact Supplier

Amber Liu Chat Now
Telephone
86-335-8015417
Address
Zaozhuang,Shandong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Health & Medical > Medical Devices > Emergency & Clinics Apparatus
Categories
Hi~