PM60D (ECG,Spo2,NIBP,PR)

PM60D (ECG,Spo2,NIBP,PR)

Negotiable /Pair

Min.Order:1 Pair

Supply Ability:
0 Pair / Pairs per Month
Payment Terms:
T/T L/C D/P D/A
Delivery Detail:
7 days

Quick Details View All >

Brand Name:
Contec
Place of Origin:
China
Model Number:
PM60D

Contec Medical Systems Co., Ltd

Business Type: Trading Company
Main Products: Pulse oximeter , Fetal Monitor , Fetal Doppler , B-Ultrasound , ECG Machine , Patient Monitor , Stethoscope , ECG Series , Endoscope , EMG/EP PSG , Surgical Unit , Infusion Pump , Transcranial Doppler , Blood Pressure Monitor , Medical Image System , OEM.

Product Details

Feature: ■ Routine Check Mode and Continuous Monitoring Mode ■ Data Graph and Trend Table Review ■ Rich Analysis Report ■ Perfect Mount Solution ■ Convenient operation by touch screen ■ Large SD card memory for more than 2000 patient cases storage ■ Sync with PC based Sofrware (WinXP and WinVista) Performance Specifications: ■ Display:3.5" Color TFT ■ Resolution:320x240 ■ Display Mode:Standard face, Waveform face, SPO2 view, ECG view, BigNum view ■ Indicator:Power indicator light, Alarm sound, Pluse tone ■ Interface:One dual-purpose socket for connecting sensors and communication cables ■ Power Supply:DC 5V, <500MA ■ Battery:Builtin Li-Polymer, 2 hours for charging, 3 hours ■ for continous working.10 hours for standby mode ■ Trend Graph:Resolution from 1s, 5s, 10s. Maximum time 96 hours. ■ Trend Table:Resolution from 1s, 5s, 10s. Review up to 1000 items. ■ Alarm:Ajustable High and Low limits. Three level audible and vistual alarm ■ User Configuration:All the color of parameters and waves can be set according to user's willing Technical specifications: ■ Safety ■ Meet the requirment of IEC60601 series ■ Type of Protection:Class II with internal electirc power supply ■ Degree of Protection:BF ■ Dimention and Weight ■ Dimention:92(W)x82(H)x22(D)mm ■ Weight:136g(with battery) ■ Operation Environment: ■ Temperature:0℃~ +40℃ ■ Humidity:15% ~ 95% ■ Storage Environment: ■ Temperature:-20℃~ +60℃ ■ Humidity:10% ~ 95% ■ Patient Range ■ Neonate ,Pediatric and Adult SPO2: ■ Measurement Range:0 ~ 100% ■ Resolution:1% ■ Accuracy:±2%(70%~100%, Adult/Pediatric, non-motion) ±3%(70%~100%, Neonate, non-motion) 0% ~ 69% unspecified ■ Alarm Range:0% ~ 100% ■ Refreshing Rate:1s Pulse Rate: ■ Measurement Range:25 ~ 250 bpm ■ Resolution:1bpm ■ Accuracy:±bpm (non-motion) ■ Alarm Range:25 ~ 250 bmp ■ Refreshing Rate:1s ECG: ■ Lead mode:3-lead or 5-lead ■ Lead selection: I, II, III, AVR, AVL, AVF, V ■ HR range:15 ~ 300 bpm ■ ECG Waveform:2 channals ■ Accuracy:±2bpm or ±2%, which is greater ■ S-T segment detection, range: -2.0mv ~ +2.0mv ■ Arrhythmia analysis: 13 kinds of arrhythmia ■ Alarm Range:15 ~ 300 bpm NIBP: ■ Method:Oscillometry ■ Mode:Manual/Auto/Contiuous ■ Measurement Range:25 ~ 260mmHg ■ Atuo Measure Interval: 5, 10, 15, 30, 45, 60, 90 minutes ■ Resolution:1mmHg ■ Overpressure Protection: 300mmHg ■ Alarm range:25 ~260mmHg

Contact Supplier

Amber Liu Chat Now
Telephone
86-335-8015417
Address
Zaozhuang,Shandong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Health & Medical > Medical Devices > Emergency & Clinics Apparatus
Categories
Hi~