CMS50D+ Pulse Oximeter

CMS50D+ Pulse Oximeter

Negotiable /Pair

Min.Order:1 Pair

Supply Ability:
0 Pair / Pairs per Month
Payment Terms:
T/T L/C D/P D/A
Delivery Detail:
7 days

Quick Details View All >

Brand Name:
Contec
Place of Origin:
China
Model Number:
CMS50D+

Contec Medical Systems Co., Ltd

Business Type: Trading Company
Main Products: Pulse oximeter , Fetal Monitor , Fetal Doppler , B-Ultrasound , ECG Machine , Patient Monitor , Stethoscope , ECG Series , Endoscope , EMG/EP PSG , Surgical Unit , Infusion Pump , Transcranial Doppler , Blood Pressure Monitor , Medical Image System , OEM.

Product Details

Major Features ■Integrated with SpO2 probe and processing display module ■Small in volume,light in weight and convenient in carrying ■Operation of the product is simple ,low power consumption ■Operation menu for the function setting ■SpO2 value display ■Pulse rate value display, bar graph display ■Pulse waveform display ■The display mode can be changed ■A pulse rate sound indication ■With measured data overruns limits and low-voltage alarm function, the upper/down alarm range is adjustable ■Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage, and with alarm function ■With SpO2 value and pulse rate value of storage, the storage data can be uploaded to computers ■Real-time data can be transmitted to computers ■Automatically power off function: when the device is under the state of measuring interface . it will automatically power off within 5 seconds if the finger falls out of probe ■RF Wireless communication function(Option) ■Connected with an external oximeter probe(Option) Main performance Display Mode: 0.96" Dual color OLED display Screen Resolution: 128*64 SpO2 Measuring Range: 0%~100%, (the resolution is 1%). Accuracy: 70%~100%: ±2% ,Below 70% unspecified. PR Measuring Range: 30bpm~250bpm, (the resolution is 1bpm) Accuracy: ±2bpm or ±2% (select larger) Measurement Performance in Weak Filling Condition: SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger). Resistance to Surrounding Light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%. Power Consumption: less than 80mA Voltage: DC 3.0V Power Supply: 1.5V (AAA size) alkaline batteries × 2 Battery Working Hour: The minimum continually work time is 24 hours , theoretical number is 32 hours. Safety Type: Interior Battery, BF Type Accessories Sell in standard: ■A hanging rope ■A user manual ■A data line ■A disk (PC software) Sell in addition: ■RF wireless module ■Oximeter probe(Refer to probe application instruction for details and notice renewal) Physical Identity Dimension: 58.5(L) × 31(W) × 32 (H) mm Weight: About 52g (with the batteries) Qualification Passed CE

Contact Supplier

Amber Liu Chat Now
Telephone
86-335-8015417
Address
Zaozhuang,Shandong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Health & Medical > Medical Devices > Emergency & Clinics Apparatus
Categories
Hi~